By purchasing a SANlight Q1W

 DIM

 LED-light you have decided on a high-quality product, which will give you much pleasure. 

Please read the operating instructions before using your Q1W

 DIM

 LED-light, as incorrect use can cause damage to the lamp or 

plants. If the Q1W is not used properly, all warranty claims and the manufacturer‘s product liability expire.

ATTENTION photobiological safety advice: 

The Q1W DIM LED module is used exclusively for illuminating plants and is not intended for general lighting purposes. According to DIN EN 62471, the Q1W DIM LED module is classified in risk 

group 1. Nevertheless, avoid unnecessarily long irradiation and looking directly into the light source.

Operation manual

 SANlight Q1W

 DIM

Read before operating

Handling the LED module and general warnings

To clean the secondary optics of your Q1W DIM, please use a soft, non-abrasive cloth with distilled water. Under no circumstances should you use other 
aids such as cleaning agents, damp cloths, etc. For cleaning, the luminaire must be disconnected from the mains.  Make sure that the secondary optics 
are not scratched by cleaning. Scratched or damaged secondary optics result in reduced light output and poor light control. To clean the heat sink, 
please also use a soft, non-abrasive cloth with distilled water. For very heavy soiling, you can use a mild soapy water solution.

Hazard warnings
ATTENTION: 

Avoid direct contact of the LED module (1) with plant parts.

ATTENTION: 

The 

Q1W DIM

 may be operated up to a maximum ambient temperature of 35 °C. The minimum ambient temperature at which the 

Q1W 

DIM

 may be operated, is 5 °C.

ATTENTION: 

Avoid unnecessary mechanical stress on the LED-module, the power-supply, and all cables.

ATTENTION: 

Carefully secure the LED-module (1) against falling and mechanical stress of any kind. 

ATTENTION: 

The LED-module (1) can become up to 65 °C hot depending on the ambient temperature. Make sure there is sufficient ventilation at the 

place of use and keep a safety distance of at least 15 cm from surrounding objects. The LED-module (1) must not be operated in closed rooms without 
air supply.

ATTENTION: 

Use the 

Q1W DIM

 only with the included power-supply. (4) The use of other power-supplies will destroy the LED-module.

ATTENTION: 

If damage can be seen on the power-supply unit, on the LED-module, on the cables or on the suspension, the 

Q1W DIM

 must no longer 

be operated. In this case, disconnect the Q1W from the general power-supply immediately. To do this, pull the mains connection cable out of the socket. 

Figure 1

Figure 2

Figure 3

Figure 4

Figure 5

Figure 6

Technical data

LED-module power consumption typ.

Power-supply supply voltage

Power-supply Input voltage frequency

Power-supply Power factor

LED-module operating voltage

LED-module operating current

Power-supply maximum output voltage

Maximum ambient temperature for operation

Minimum ambient temperature for operation

Maximum humidity for operation

LED-module maximum temperature

Power-supply maximum temperature

Emission range

Dimensions of LED-module 

Dimensions of power-supply 

Weight of LED-module including connection cable

Weight of power-supply unit including connection cable 

Module efficiency in range of emission wavelengths 

B

PF 

Degree of protection power-supply  

Degree of protection LED-module

Protection class power-supply

5

0

 W

120 – 2

77

 V (AC)

50/60 Hz

0,9

5

<57 V (DC)

0,8 A (DC)

90

 V (DC)

35 °C

5 °C

90 %

65 °C

90 °C

410 – 760 nm

174x80x55 mm

119

x

68

x3

4

 mm

633 g

705,4

 g

>2,7 µMol / (W*s)

12

5

 µmol/s

IP67

IP40

I (with protective conductor)

Attention: Do not look 
directly into the light source. 

Ne regardez pas directement 
dans la source lumineuse.

The LED-light must not be disposed of in household waste! For disposal, the light can be handed back to the manufacturer. The disposal costs are borne by the manufacturer. Alternatively, the light can be delivered to a 
disposal company for electrical appliances. 

La lampe LED ne doit pas être jetée avec les ordures ménagères! Pour l‘élimination, la lumière peut être restituée au fabricant. Les coûts d‘élimination sont à la charge du fabricant. 

Alternativement, la lumière peut être livrée à une entreprise d‘élimination des appareils électriques.

Attention: The light is not 
suitable for covering! 

La 

lumière n‘est pas adaptée 
pour couvrir!

Caution: Risk of shock. Disconnect power before 
relamping. 

Attention: Risque d’électrocution. Débrancher 

l’alimentation avant de remplacer la lampe.

Keep a safety distance of at least 15 cm to surrounding objects. 

Maintenez une distance de sécurité d‘au moins 15 cm par rapport 
aux objets environnants.

Contact manufacturer:

 SANlight GmbH, 

Montafoner Str. 14

,

 67

80

 

Schruns

, Austria, www.sanlight.com, [email protected]

 

Good luck using your SANlight lamp. For questions, suggestions or further information, please contact your dealer or us.

Protected against solid objects with a diameter 
≥ 1.0 mm; no protection against water. 

Protégé 

contre les corps étrangers solides d‘un diamètre ≥ 
1,0 mm; pas de protection contre l‘eau.

IP40

1. LED Module
2. Mounting Brackets
3. DC Power Cord with Plug
4. Power Supply, Main Power Cord
5. DC Power Cord with socket
6. Power plug, AC Power Cord

Dimming function

Dim OFF, 20%, 40%, 60%, 80%, 100%

Guarantee Policy

This device has been designed, manufactured and tested in 
accordance with the European safety standard (EN60598/CE). The 
guarantee for the LED-light and accessories is 3 years from the

 

date of purchase. The guarantee does not apply to equipment that 
has not been installed and maintained as specified in this manual. 
The manufacturer assumes no responsibility for damage caused 
by unauthorized or incorrect use. In case of damage, the device 
(LED-light incl. power supply) must be returned to the respective 
SANlight sales partner, from whom the product was purchased. 
They send the defective goods to the manufacturer, SANlight 
GmbH. After repair by the manufacturer, the device is returned to 
the respective sales partner.

Work and repairs

Repairs and works may only be carried out by the manufacturer. 
If repairs, modifications and other works are not performed by the 
manufacturer, the manufacturer ‘s warranty and product liability 
expire.

Scope of delivery

Figure 1 shows all components of your SANlight 

Q1W DIM

. Please 

check the content of the packaging for completeness and damage. 
Never use damaged components.

Fastening and suspension of the LED module

The LED module (1) can be positioned in 3 different orientations 
using the two holding brackets (2). When hanging the LED-module, 
keep a safety distance of 15 cm from surrounding objects. Make 
sure that the brackets (2) are properly mounted and secure the 
LED-module (1) sufficiently to prevent it from falling accidentally.

Installation and removal of the mounting bracket

The supplied mounting brackets (2) can be attached to the two 
grooves in the edge area of   the heat sink and thus allow the lamp 
to be oriented flexibly. Figures 2 and 3 show the different mounting 
options. To hang in the retaining bracket (2), spread it apart by 
hand. Figure 4 illustrates the installation and removal of the retaining 
bracket (2).

Electrical connection of the 

Q1W DIM

 

For powering, the LED-module (1) must be connected to the 
power-supply unit (4). To do this, connect the plug of the DC 
supply-cable (3) on the LED-module to the socket on the DC 
supply-cable (5) of the power-supply unit (4). For this purpose, the 
plug and the socket have printed arrows that must point towards 
each other. (see Fig. 5)

Connection sequence

The attachment order as shown in Figures 5 and 6 must be 
observed. First connect the DC supply-cable (3 and 5) then the AC 
supply-cable (6). When disconnecting the 

Q1W DIM

 from the mains 

power supply proceed in the reverse order (first unplug the AC 
supply-cable, then the DC supply-cable). Disregarding this advice 
can cause damage to the 

Q1W DIM

 and will void all warranty and 

product liability claims.

Laying the cables

When laying all cables, ensure a strain-relieved fixation. Cabling 
should not be exposed to tensile load. All cables must be comple-
tely unwound. The LED-module (1) and the power-supply unit (4) 
must not be operated with coiled cables.

Power supply

When using several 

Q1W DIM

 modules, a distance of at least 10mm 

must be maintained between the individual power supplies. Sta-
cking the power-supply units (4) is not permitted.   

ATTENTION: 

The AC power-plug is not waterproof. Avoid direct 

contact with liquids of all kinds and only operate the power-supply 
unit in rooms with a humidity below 

8

0%.

Dimming function
You can control the dimming function with the rotary switch on the 
driver. The dimming power ranges from 0% - 100% and is 
subdivided in 20% steps: 0% - 20% - 40% - 60% - 80% - 100%.

 