6
6 – Cylindrical milling cutter
Grinding of lignified foot nail surfaces as well as
smoothing of these. For this purpose, apply the milling
cutter horizontally to the nail surface and remove the un-
wanted layer of nail using slow circular movements.
7 – Flame milling cutter
For removing ingrowing nails. Carefully guide the flame
cutter up to the part to be treated and remove parts of
the nail as necessary.
Always check results regularly during treatment. As soon as the application
becomes unpleasant, stop the treatment.
4. Cleaning /care
Before cleaning the power unit, always unplug it from the socket outlet!
– Clean the instrument with a slightly moistened cloth. You can also
moisten the cloth with mild soap suds to remove more stubborn dirt.
– If necessary, for reasons of hygiene, the attachments can be cleaned with
a cloth or brush moistened with alcohol. Dry them carefully afterwards.
– Do not drop the instrument.
– Make sure that no water enters the instrument. But if this should happen,
do not use the instrument again until it is completely dry.
– Do not use chemical detergent or scouring agents for cleaning.
– Never immerse the instrument or plug-in power unit in water or other liq-
uids.
5. Technical data
Power unit voltage
Input:
100 – 240 V AC / 50 – 60 Hz
Output: 30 V DC / 250 mA
Speed:
3.800/4.600 U/min ±14%