4. Prepare measurement
Inserting battery
• Remove the battery cover from
the back of the monitor.
• Insert four AAA 1.5 V alkaline
batteries. Making absolutely
sure that you insert them with
the correct polarity as marked.
Never use rechargeable batter-
ies.
• Replace the battery cover carefully
If the battery change
is continuously illuminated, measure-
ment is no longer possible and you must replace all the bat-
teries. Once batteries have been removed from the device, the
time must be reset.
Used batteries do not belong in the household waste. You are
legally obliged to dispose of the batteries. Dispose of them via
your specialist electrical supplier or local collecting point for
recyclable waste
Note:
Batteries containing pollutant substances
are marked as follows: Pb = Battery contains
lead, Cd = Battery contains cadmium,
Hg = Battery contains mercury.
Setting date, time and language
It is vital to set the date and time. This is the only way that
measurements can be saved and recalled with the correct date
and time. The time is shown in 24 hour format.
Proceed as follows to set the date and time:
• Switch on the blood pressure monitor with the button.
• Press the memory button for at least three seconds
M
.
The year display will start to flash.
• Set the year with the function buttons
–
/
+
and confirm with
the memory button
M
.
The month display will start to flash.
• Set the month (1–12) with the function buttons
–
/
+
and con-
firm with the memory button
M
.
• Set the day, hour and minutes and confirm each setting with
the memory button
M
.
Operation with the mains part
You can also operate this device with a mains part.
When doing so, there must not be any batteries in the battery
compartment. The mains part can be obtained from specialist
retailers or from the service address using order number 071.60.
• To prevent possible damage to the device, the blood
pressure monitor must only be used with the mains part
described here.
• Insert the mains part into the connection provided for this
purpose on the right-hand side of the blood pressure moni-
tor. The mains part must only be connected to the mains
voltage that is specified on the type plate.
• Then insert the mains plug of the mains part into the mains
socket.
• After using the blood pressure monitor, unplug the mains
part from the mains socket first and then disconnect it from
the blood pressure monitor. As soon as you unplug the
mains part, the blood pressure monitor loses the date and
time setting but the saved measurements are retained.
4x1.5V AAA (LR03)