13

3. Unit description 

1. Cuff
2. Cuff line
3. Cuff connector
4. Display
5. START/STOP button 
6. Memory button M+ 
7. SET button
8. Function buttons -/+
9. WHO scale

Icons in the display:

  1. Systolic pressure
  2. Unit in mmHg
  3. Diastolic pressure
 4.  

Pulse symbol 

 and calculated pulse value

  5. Time and date
  6. Cardiac arrhythmia symbol 
 7.  

Average values of the 3 most recent measurements – AVG

  8. Pump up, release air (arrow)
  9. WHO classification
10. Battery replacement symbol 
11. Symbol for users 1, 2, 3 and 4

SYS

 mmHg

DIA

  mmHg

PULSE

 

/min

SET

M +

+

4

1

2

3

6

7

8

9

5

WHO

5

1

6

7

8

9

10

11

3

4

2

Summary of Contents for SBM 21

Page 1: ...onitor 11 18 F Mode d emploi Tensiom tre 19 27 I Instruzioni per l uso Misuratore di pressione 28 35 r 36 44 SBM 21 Serviceadresse Hans Dinslage GmbH Riedlinger Stra e 28 88524 Uttenweiler GERMANY Tel...

Page 2: ...ctor Never use them to make medical decisions independently e g regarding medication and dosage thereof There may be incorrect measurements where there is cardio circulatory disease as well as with ve...

Page 3: ...atteries at the same time Never use different types of battery battery brands or bat teries with different capacities You should preferably use alkaline batteries Repair and disposal Batteries do not...

Page 4: ...ic pressure 2 Unit in mmHg 3 Diastolic pressure 4 Pulse symbol and calculated pulse value 5 Time and date 6 Cardiac arrhythmia symbol 7 Average values of the 3 most recent measurements AVG 8 Pump up r...

Page 5: ...ry contains mercury Setting date and time You should set the date and time without fail Otherwise you will not be able to save your measured values correctly with a date and time and to access them ag...

Page 6: ...want to carry out the measurement Start the measurement by holding the button After check ing the display during which all numbers light up the cuff pumps up automatically Whilst the cuff is pumping...

Page 7: ...lling the heart beat The symptoms omitted or premature heart beats slow or exces sively fast heart rate may be caused among other things by heart disease age physical predisposition excessive use of s...

Page 8: ...ror messages troubleshooting In case of faults the Err message appears in the display Error messages can occur when 1 inflation pressure is higher than 300 mmHg 2 blood pressure is unusually high or l...

Page 9: ...se note that portable and mobile HF communication systems may interfere with this in strument For more details please contact customer service at the address indicated The instrument is in line with t...

Reviews: