Handle
Release
1.
Remove the attachment hose from the lower hose
retainer and look into the hose retainer for any
obstructions. Proceed to Step 2 to check for any other
blockages.
4.
Check for blockages in the brush roll area and remove
any obstructions found there. The base hose can be
cleared of any blockage by using a blunt instrument.
5.
After the blockage is removed, replace the hood and
tighten the two hood screws (see Figure 2). Raise the
handle to the upright position (see Figure 3) and replace
the hose into the lower hose retainer.
Upright Position
Operating Position
Lowest Position
for cleaning
under furniture
How to Check and Clear Blockages in Base
2.
Remove the hood by loosening the two fasteners
located on the top of the hood and lifting upward.
These fasteners need only a quarter turn to lock or
unlock the hood. (See padlock graphics on the hood.)
3.
Step on the handle release and lower the handle all
the way to the floor.
14