Sanitaire SC6085B Owner'S Manual Download Page 6

6

MAINTENANCE GUIDE

To receive reliable service from this equipment, 

regular daily maintenance is required.
1.  Keep the equipment clean, both inside and 

out.

2.  Lubricate brass quick disconnects with a 

quality lubricant.  (Fig 9)

3.  Flush solution systems after use with clear, 

clean water. (A white vinegar solution of 1 part 

vinegar to 8 parts water may also be used). This 

will counter-act hard water and alkaline deposits 

and aid in keeping orifices clean.

4.  Do not allow fluid, either in solution or waste 

tank, to sit overnight.  The unit should be emp-

tied and cleaned daily. 

5.  Clean the strainer in the solution tank, the 

filters on the vacuum stack in vacuum tank, and 

all lint filters in the inlet or vacuum tanks daily.  

(Fig 10) 

6.  When the unit is not in use, leave the vacuum 

tank lid open.  (Fig 11)

7.  At the end of each day, run the vacuum for 

3 minutes with lid open and filter off.  (Figs 11 & 

12)

Fig 9

Fig 10

Fig 11

Fig 12

CAUTION - 

Do not operate without the filter 

and ball float valve in place.

For cleaning machines, parts & supplies click/visit www.southeasternequipment.net

For cleaning machines, parts & supplies click/visit www.southeasternequipment.net

Summary of Contents for SC6085B

Page 1: ...rchase 2014 Electrolux Home Care Products Ltd IMPORTANT Do not return this product to the store Call 1 800 800 8975 Monday Friday 8 00 AM to 7 30 PM and Saturday 10 AM to 6 30 PM Central time or visit...

Page 2: ...itten or verbal which extend beyond the description found in this manual GROUNDING INSTRUCTIONS This appliance must be grounded If it should malfunction or breakdown grounding provides a path of least...

Page 3: ...return it to a service center Do not pull or carry by the cord use the cord as a handle close a door on a cord or pull cord around sharp edges or corners Do not run the unit over the cord Do not handl...

Page 4: ...the following instructions Please inspect your cartons for any damage including concealed damage that might have occurred during shipment Any damage is the responsibility of the freight carrier and sh...

Page 5: ...solution to recovery tank Fig 8 8 Empty the recovery tank by using the drain hose on the front of the machine Do not use the same pail to fill the solution tank as this can result in putting dirt and...

Page 6: ...ither in solution or waste tank to sit overnight The unit should be emp tied and cleaned daily 5 Clean the strainer in the solution tank the filters on the vacuum stack in vacuum tank and all lint fil...

Page 7: ...ay be left in the pump and internal solution line for protection against freezing TROUBLESHOOTING NO ELECTRICAL POWER CAUSE 1 Defective power cord 2 Circuit breaker off or blown fuse SOLUTION 1 Replac...

Page 8: ...ol valve 2 Clogged or faulty quick disconnect 3 Punctured pump diaphragm 4 Clogged jets SOLUTION 1 Check valve for debris 2 Depress plunger on solution hose quick disconnect on against inside wall of...

Page 9: ...CAUSE 1 Clogged strained in solution tank 2 Punctured pump diaphram 3 Defective rectifier or motor SOLUTION 1 Clean and replace 2 Replace 3 Replace For cleaning machines parts supplies click visit ww...