user-manual saniswiss “biosanitizer-automate” 

(230V)

how to use the selector 

   vol. to be treated            spraying-time                   consumption

 

10 

2 mn  20 sec 

40  ml

 

20 

3 mn   30 sec 

60  ml

 

25 

4 mn   50 sec 

80  ml

 

35 

6 mn 

 

100  ml

 

40 

7 mn   10 sec 

120  ml

 

50 

9 mn  30 sec 

160 ml

 

70 

12 mn 

 

200  ml

 

130 

24 mn 

 

400  ml

 

200 

36 mn 

 

600  ml

 

260 

48 mn 

 

800  ml

 

350 

60 mn 

 

1000  ml

emergency stop 

The device can be stopped at any moment by pressing on the button 
to activate the spray (8).

bad functionning

the device does not start and the sign light of the switch on/off (3) 
does not ignite:

-  verify the power of your electrical network
-  verify the fuse (2) behind of the device.

the device works but does not uses the product:

-  verify that the jet (9) is not tapped

waranty

A copy of the present certificate of guarantee of the biosanitizer-auto-
mate should be kept affectedly by the customer; it shall be presented 

to the retailer or to the saniswiss Inc. ch. des tulipiers 19, 1208 Geneva, 
Switzerland, to attest of the guarantee, the other copy shall be kept by 
the retailer.

clauses

What follows is not exclusive of the legal guarantee foreseen by the 
articles 1641 and following ones of the civil code concerning hidden 
defects.

objects

The guarantee consists of the free supply of the parts that are consid-
ered defective by our technical services, the exchanged parts becomes 
the property of the company.
Repairs required afterward wrong operations, abnormal uses, care-
lessness or excess loads of the device as well as those required  
because of variations of the electricity network , voltage surges or 
defective installations, etc. can not be guaranteed. Also the guaran-
tee nullifies in case of intervention and repair by qualified techni-
cian not member of the saniswiss Inc. The seals of the device have 
to be untouched. Besides, if an abnormal corrosion of supple parts, 
radiator hoses, joints, was noticed indicating the use of another 
liquid, the guarantee would be also void.

transportation

The material travels under the responsibility of the user; in case of dam-
ages during the transportation, the addressee has to make any reserves 
to the carrier before taking delivery of the device.

duration

The biosanitizer-automate is guaranteed during a period of 2 years as 
from the day of the reception of the device by the user.

in case of doubts reading the user-manual, please contact our 
support specialist at saniswiss Inc. t +41 22 718 75 75

waranty certificate 

biosanitizer-automate saniswiss

customer copy

device

 biosanitizer-automate            

SN :

……..

timer 10 – 350 m

3

                 

The biosanitizer-automate saniswiss is made of quality. 

saniswiss undertake for a duration of 2 years to guarantee any 

defect of material or manufacture.

general

diffuser type

           

name

 biosanitizer-automate             

protection class

 IP10.

operating temperature

 10°C to 40°C.

storage temperature 

0°C to 50°C.

operating humidity and storage

 25% to 75%.              

class 1 power classification

do not use in presence of a flammable anesthetic mixture. 
intermittent. 

medical classification

 according to Medical Device Directive 93/42/EEC 

class IIa medical device (marking CE1253).

symbol record 

        security check                          

      protective earth.

precautions 

The manufacturer will not be held liable for any bodily harm or material 
damages caused by inappropriate or abnormal use of the devise contrary 
to the precautions recommended in the list below (non exhaustive list) :
-  use only the product saniswiss-biosanitiizer™
-  make sure that electric power matches your country’s current standards
-  dot not insert an object or fluid in the nozzle of biosanitizer-automate  
  whether on or off 
-  avoid moving biosanitizer-automate when it contains the product,  
  place it in order to keep the bottle horizontaly
-  check the presence of the nozzle (9)
-  remove the bottle from the biosanitizer-automate for transport
-  check that room is not equipped with alarm sensor. If this happens, 
  a specialist may preferably adapt the sensitivity of the alarm sensors.
-  do not use the unit on it’s support

The device diffuses a chemical substance, therefore it is necessary to 
pay attention :
-  do not inhale the product
-  do not smoke near the biosanitizer-automate while it is working
-  do not steer it towards an incandescent zone
-  do not be located in the room during the spray

use

-  move the unit to the front and install the support located under the unit
-  screw the cartridge of saniswiss-biosanitizer (750 ml)
-  tighten to prevent sagging
-  close back the support 
-  connect the device with the electrical network 230/50 Hz with the 
  power cable (1)
-  select with the button (8) the volume of the room to be treated 
  (it corresponds to a time of use, check table 5)
-  press on the switch (3) to power on the biosanitizer-automate
-  steer exit ( 6 ) towards zones to be diffused using the handle (4)
-  press on the “Start On” button (8) a buzzer rings during 15 
  seconds and leaves you the time to go out of the room 
   to be treated. The device stops automatically.
-  wait at least for 90 minutes before going into the room
-  press on the switch (3) to power off the device
-  change the filter (10) once or twice a year, according to it wear
-  check the effectiveness, regularly with our culture dishes

> if a problem appears, then disconnect the device and to 
  consult your retailer

maintenance

The device should be kept in a dry and clean place remote from any 
possible projections. During cleaning, do not use spray into the holes 
of the nozzles nor the interstice of the automate. Clean and remove 
debris that could stick on the metal-filter located under the automate.

device presentation

power Cable

2

  used fuse

3

  switch for power on/off

4

 support

5

  button of nose of the diffuser

6

 nozzle

7

 bottle 

8

  button to activate the spray, “start“ button

9

 jet

10

  volume selector 

characteristics

power 

1000 W

tension 

230 V mono+T

frequency 

50 to 60 Hz

intensity 

4,5 A

maximum intensity  

10 A

speed of rotation of the turbine 

22000 rpm

tank capacity 

750 ml

gross weight 

9,7 kg

net weight (without liquid or bottle)  9,0 kg
size 

h 39cm x

 

53,6cm x 29cm

performances

speed-exit of air             

80 m/s

maximal volume to be treated      350m

3

average biosanitizer output       

350ml/h