background image

 

SECURITY INSTRUCTIONS 

 

All installations, maintenance, and repairs must be 
carried out by qualified technician.  
 
Saniflow advises:  
 
1. Become familiar with the appliance and read the 
instructions carefully before use.  
 
2. Disconnect the appliance before carrying out 
maintenance or repair.  
 
3. To ensure safe operation, follow the indications 
given in this manual.  

Summary of Contents for M09A

Page 1: ...1 HAND DRYER MACHFLOW UL COVER SPECIFICATION M09A STEEL WHITE EPOXY M09AC STAINLESS STEEL BRIGHT FINISH M09ACS STAINLESS STEEL SATIN FINISH ...

Page 2: ...ed motor adjustable from 450 to 1300 W Maximum air velocity 203 mph 250 W heating element Electronic infrared detection sensor adjustable from 2 to 8 MACHFLOW UL High speed airflow with minimum energy consumption ...

Page 3: ...3 MAINTENANCE This file contains the instructions and images that describe the replacement of the components of this hand dryer Consult security instructions before using the equipment ...

Page 4: ...carried out by qualified technician Saniflow advises 1 Become familiar with the appliance and read the instructions carefully before use 2 Disconnect the appliance before carrying out maintenance or repair 3 To ensure safe operation follow the indications given in this manual ...

Page 5: ...me to the inside world of MACHFLOW UL we will show you how to change the main components of the hand dryer 1 The cover Page 6 2 The motor Page 7 10 3 How to adjust the airflow distance detection Page 11 4 The electronic board Page 12 15 5 The heating element Page 16 4 General maintenance Page 17 ...

Page 6: ...6 To remove the cover Step 1 Unscrew the screws from the cover 2 units with The Machflow security key supplied Step 2 Carefully remove the cover from the base Pay attention not to damage the led sensors ...

Page 7: ...7 Universal brush motor 18 000 26 000 r p m Minimum energy consumption Ultra fast drying time Minimum CO2 emissions Minimum noise pollution ...

Page 8: ...e nozzle is extremely fixed it s suitable to use a plain screwdriver to make this step easier but taking care not to damage the plastic pieces Step 1 With the support of a screwdriver remove 4 screws from the upper nozzle To remove the motor ...

Page 9: ...9 Step 3 Once we clearly see the motor disconnect 2 motor cables it s recommended to use pliers ...

Page 10: ...10 Step 4 Take out the motor for its replacement Step 5 To install a new motor follow the above steps in the other way around ...

Page 11: ...11 How to adjust the airflow distance detection on site The adjustment can be made by moving the respective cursors of the two linear potentiometers as shown in this figure ...

Page 12: ...ectronic board P C B Board Allow adjustment distance detection Allow adjustment motor power rpm The Machflow is assembled with the motor potentiometer set at maximum in both distance detection and motor rpm ...

Page 13: ...13 Step 2 With the support of pliers take out the bridles that hold the cables to the base Step 1 Unscrew the supply cables of the electronic plate To remove the electronic board ...

Page 14: ...14 Step 4 Carefully remove the electronic plate paying attention not to damage the cables Step 3 With a plane screwdriver take out the Nylon screw that fixes the electronic plate to the base ...

Page 15: ... Step 6 To install a new electronic plate follow the above steps in the other way around Step 5 Once the electronic place is out of its housing unscrew the motor cables 2 connected to the equipment wiring ...

Page 16: ...16 Heating element ...

Page 17: ...f the unit like the motor the heating element the fan wheel and the electronic board with a small soft brush The infrared sensor should be cleaned with a cloth dampened in alcohol Keep alll air passages unblocked free of dust and build up by cleaning with a small soft brush Corrective Maintenance Spare Parts All the spare parts mentioned are available on request ...

Reviews: