Care and Maintenance

Regular cleaning will preserve the appearance and integrity of the surface. Stainless steel can 

easily be cleaned and kept stain-free using various methods. 

Recommendations: 

•  Clean with an abrasive cleaner like, Bon-Ami or Zud weekly or bi-weekly. Always scrub in the 

direction of the grain or polish lines. Another option is to use Baking soda. Make sure to 

rinse well and dry. Illustration A 

•  Most soaps and detergents contain chlorides, we recommend rinsing the stainless-steel 

sink with hot water after use, to prevent corrosion. Illustration B

•  Regularly dry your sink to prevent water and surface rust marks. Illustration C
•  Do not leave salt in the sink or near a saltwater environment. 
•  Use a quality stainless steel cleaner and follow cleaner instructions. Wipe along the grain 

(NOT against). Illustration D

Things to Avoid:

•  Avoid harsh abrasive cleaners and corrosive chemicals. 
•  Avoid abrasive scouring pads, carbon steel brushes and steel wool for cleaning as iron 

particles left behind can lead to rust. 

•  Avoid the use of oily rags or greasy cloths when wiping the surface. To avoid water spots, 

wipe dry after use. 

Additional Tips:

•  Regularly drying your sink works wonders to prevent water and surface rust marks.
•  Wear rubber gloves when working with cleaners to protect your hands.
•  Never mix cleaners. Some products react to create dangerous gases.
•  There are thousands of blended or compound cleaners on the market. Users are advised to 

contact suppliers of solvents for information on their applications on stainless steel.

•  DO NOT USE SOLVENTS in closed spaces or while smoking.
•  Note: Columbia does not recommend use with harsh chemicals.

Illustration A

Illustration B

Illustration C

Illustration D

CARE AND MAINTENANCE

Summary of Contents for 532FA

Page 1: ... Free Floor Mount Stainless Steel Scrub Sink AC Models 532FA and 532FA 0 5 Battery Models 532FB and 532FB 0 5 of Domestic and Foreign Parts Columbia does not recommend use with harsh chemicals Product Compliance NSF ANSI 2 Food Equipment NSF ANSI 372 Lead Free Compliant ASME A112 18 1 ...

Page 2: ...unt sensor control boxes at desired location on wall 4 Connect power line from sensor to control box 5 Attach supply tube from faucet to control box 6 Connect hot and cold water from the source to mixing check valve s 7 Remove aerator from the spout assemblies and flush water system see step 7 sensor installation instructions 8 Check connections for leaks 9 Replace aerator onto the spout s Step 4 ...

Page 3: ...93 7mm 45º 2 875 73 02mm 75 20mm 16 5 419mm 20 495 3mm 4 101 6mm Top 28 711 2mm 1 5 38mm 1 5 38mm 15 5 393 7mm mounting holes 9 228 6mm on center 10 25 260 35mm Cross breaks to aid drainage 3 5 drain hole 88 9mm 5 75 146 05mm hole center to wall 875 22mm dia holes 2 27 686mm 8 228 6mm 10 5 266 7mm 5 R 12 7mm Floor Mounting Detail 5 dia Floor Mounting Holes 9 on Center 1 5 Leg Thickness 75 From Edg...

Page 4: ...4 COLUMBIA SPECIFICATIONS AC OR BATTERY POWERED 800 626 2117 columbiasinks com info columbiasinks com 2021 Columbia Products SCRUB SINK WITH ELECTRONIC SENSOR Leg Assembly x 6 ...

Page 5: ...uality stainless steel cleaner and follow cleaner instructions Wipe along the grain NOT against Illustration D Things to Avoid Avoid harsh abrasive cleaners and corrosive chemicals Avoid abrasive scouring pads carbon steel brushes and steel wool for cleaning as iron particles left behind can lead to rust Avoid the use of oily rags or greasy cloths when wiping the surface To avoid water spots wipe ...

Page 6: ... Plug in Input AC 120V 60 Hz or 220V UL CSA Output DC 12V 0 8A Class 2 Power Cable Armored vandal resistant Optional Multi Unit Adapter Serves up to 8 faucets UL CSA Input AC 120V Output DC 12V 3A Battery Mode Battery Powered Models 4 AA Alkaline Batteries Battery Service Life 400 000 on off cycles up to 4 years Package Includes 1 Faucet with electronic sensor 1 Control box w 6V DC solenoid 1 12V ...

Page 7: ...he sink wall and tighten the faucet onto the sink using the O Ring 8 Washer 9 and Mounting Nut 10 Attach the 90 Degree Elbow 11 to the Supply Rod 7 USE TEFLON TAPE ONLY NO PIPE DOPE 5 Reconnect the Sensor Eye Cable 17 and Power Adapter 19 connections described in STEP 2 making sure the cables are seating in the Control Box 18 housing properly 6 Attach the Compression Fitting 13 to the Solenoid Val...

Page 8: ...id In line filter is clogged Open clean out trap and check filter screen Clean or replace filter screen Solenoid coil is defective Insert new batteries or reattach power adapter Light blinks but no solenoid is clicking Replace solenoid coil Flow control is clogged Open flow control device and check Celan the flow control device Faucet will not shut off has low glow or drips The solenoid valve is n...

Page 9: ...ring 6 Piston Piston Spring and check the Piston Sleeve for corrosion 6 Re install all parts in same order as the diagram below 7 Re install solenoid on the control box and re mount box in water line 8 Check and clean Filter Screen 24 in Filter Body 22 9 Reset P C Board and make sure solenoid clicks open and thumps closed 10 Turn on water and check for leaks and proper operation For further questi...

Page 10: ...CH Sw7 Sw8 Mode On Off Auto Faucet 6700C Series Sensor Operated Mixing Faucet Control Module Settings IMPORTANT Always push the Reset Button after any adjustments 1 2 3 4 5 6 7 8 Factory Preset Switch Position Shut Off Time Delay After hands are removed Sw1 Sw2 Sw3 Delay On On On 1 Sec On On Off 2 Sec On Off On 3 Sec On Off Off 4 Sec Off On On 5 Sec Off On Off 6 Sec Off Off On 7 Sec Off Off Off 8 ...