SPECIFICATION
FM. ELECTRICAL PERFORMANCE
Model: WR-2(CE)
Brand: SANGEAN
Temp: 25
℃
R. H. : 75 % Date:2005/5/20
Condition Value
Test
No.
Test Item
Input Output
freq Nom.
Lim. 1. 2.
Unit
S/N=6dB
Min 87.5
±
0.1
Tuning Range
S/N=6dB
Max 108
±
0.1
MHz
Intermediate freq.
S/N=6dB
10.7
±
0.1
MHz
90 6 12
98 6 12
Max. Sensitivity
S/N=6dB
106 6 12
dB
μ
90 12 22
98 12 22
Usable Sensitivity
S/N=30dB
106 12 22
dB
μ
Image Rejection
127.4MHz
R.O. 106
32
26
dB
I.F. Rejection
10.7MHz S/N=6dB
90MHz
60 50
dB
3db Limiting(1mV)
98MHz
10
16
dB
μ
Min. output
60dB
μ
98MHz
0.5 3
mv
Auto Tuning Stop Sens.
98MHz
20
26
dB
μ
Current consumption
60dB
μ
98MHz
320 *400
mA
Spurious rejection
103.35MHz
Rated
output
98MHz
90 50
dB
S/N Ratio
60dB
μ
DIN Audio
98MHz
50 40
dB
Am. suppression
60dB
μ
98MHz
46
30
dB
Speaker8
Ω
98MHz
7 6
W
Mod 75kHz
**Output Power 100Hz
Load 32
Ω
10% THD
5+5 2+2
mW
T.H.D. (45KHz dev.)
R.O.
98MHz
0.2
1
%
Over load capacity
10% THD
98MHz
>106
dB
μ
100
LOW
8 6
VR=MAX
10K
HIGH
8 6
dB
100
LOW
10 8
Audio Fidelity(1K=0dB)
(W/Pre-emphasis)50uS
100/1K 10K/1K
VR=5mW
10K
HIGH
8 6
dB
Supply Voltage: AC 230V/50Hz
R.O
:
50mW
Load: 8 Ohm
Modulation: Dev.22.5kHz @400Hz
Remark:
( )
首件產品
( )
客戶抽測
( )
成品
( )
例行抽測
( )
業務樣品
( )
半成品
( )
新機種
( )
工程變更
Approved by
Released/Tested by
*
Current consumption at light on and position is max
2
Summary of Contents for WR-2
Page 16: ...TEST POINTS DIAGRAM 16...
Page 17: ...MAIN PCB TOP VIEW 17...
Page 18: ...MAIN PCB BOTTOM VIEW 18...
Page 19: ...CONTROL PCB TOP VIEW 19...
Page 20: ...CONTROL PCB BOTTOM VIEW 20...
Page 21: ...WIRING DIAGRAM 21...
Page 29: ......
Page 30: ...1 IC1 LA1177 2 IC2 TA2099F IC CIRCUIT BLOCK DIAGRAM 30...
Page 31: ...3 IC3 BA09T 4 IC4 TDA7313D 31...
Page 32: ...5 IC5 TDA7266L 6 IC6 TC7S66FU 32...
Page 33: ...7 IC7 NJM4580D 8 IC8 PT2308 33...
Page 34: ...9 IC200 H7805AM 10 IC201 XC62AP4002 34...
Page 35: ...11 IC202 TC9324F 35...
Page 36: ...12 IC203 BU1924F 13 IC204 XC61CN2002MR 36...
Page 37: ...14 IC205 XC61CN3502MR 37...
Page 43: ...MAIN SCHEMATIC DIAGRAM 43...
Page 44: ...CONTROL SCHEMATIC DIAGRAM 44...