Manual Button
Specification
Pressing the manual button M (Fig. 2) immediately opens or closes the switch contacts,
anticipating the next operation. This does not affect subsequent operations of levers L.
To Convert Form 2 Dial to Form 1
(i.e. from ‘2 ON/OFFs’ to ‘1 ON/OFF’)
1.
Remove centre locking nut and lift away the dial face.
2.
Remove the top ON/OFF lever and washers.
3.
Replace the dial face.
4.
Replace the locking nut.
Current, Voltage, Frequency:
As shown on identification plate of switch.
Ambient Temperature:
As shown on identification plate of switch.
Live Parts:
Enclosed i.e. this timer is totally protected by the enclosure.
Dirt Protection:
Normal domestic dust deposits only.
Moisture Protection:
Ordinary i.e. has no special protection against moisture.
Shock Protection:
Class 1. Functional insulation throughout.
The timer must be earthed.
Contacts:
Micro-disconnection
Important
Although every care is taken to ensure the accuracy of the electrical circuit diagrams shown, SANGAMO
or associated companies cannot be held responsible or liable for circuit connections other than those directly
associated with the S250 & Q550 ranges of time switches. As the control mechanism is similar to that
used in an ordinary quartz clock, there will be a perceptual ticking.
Due to the variety of loads, environment and applications, the battery is built into the circuit of the printed
circuit board and, therefore, the timeswitch will cease to operate or run slow after its expectancy life of
10 years (dependant on the environment).
A battery replacement kit for fitting by a suitably qualified person is available by contacting our customer
services department.
9