WIRING

Use a three core heat resistant cable with a minimum 

conductor size of 1.5mm connection to a 3kW heater. 

Connect the incoming wires to the terminal block as 

follows:

1. Live In

2. Neutral In

3. Heater Neutral

4. Boost Load

5. Off Peak Load

Link terminals 4 & 5 if using a single immersion heater.

The Powersaver Dual Flexi should be removed from the mounting box by unscrewing the 2 

captive pattress screws.

Conduit box mounting - Use either holes marked ‘C’ to secure to a single gang box or the two 

holes marked ‘B’ for a double gang box. Cable entry is through the rear breakout.

Surface mounting - Use the two holes marked ‘A’. Cable entry is through the most appropriate cut 

out.

Remove the appropriate cable entry cut outs before fixing the box, where possible drill the box to 

provide a close fitting entry for cables, taking care to remove sharp edges.

Ensure outgoing cables to the immersion heaters are securely clamped in the box. All surface 

wiring adjacent to the box should also be clamped appropriately or trunking used.

MOUNTING

COMMISIONING

When the product leaves the factory the installer 

switch is set at program 0. The product settings may 

be reviewed/entered when not connected to a power 

supply. Pressing ‘-’ or ‘+’ buttons will activate the 

display and enable the review/settings to be made.

NB: to conserve battery power, the display will turn 

off after approx 30 sec. when off power.

See user instructions for operating details.

The user may need to check with their electricity 

supplier to confirm the off-peak electricity times used 

in that area & whether these times change between 

Winter (GMT) & Summer (GMT+1).

It is the responsibility of the installer to ensure 

that the correct setting is applied for the appropriate electricity tariff.

NB: A program can comprise of 1, 2 or 3 on/off programs depending on the tariff selected. 

Some program times remain the same and some change between Winter & Summer. For 

greater flexibility, program times are adjustable within the preset limits. The clock time will 

automatically adjust no matter which program is selected.

To complete installation, take the front panel and push connectors numbered 1-5 into the 

corresponding terminal in the mounting base. Carefully present the front panel to the mounting 

box and secure with fixing screws. Ensure no wiring becomes trapped or damaged in the process.

Switch on the mains supply and put the rocker switch in the TIMED position.

Winter

 (GMT)

Summer 

(GMT+1)

ON

OFF

ON

OFF

ON

OFF

ON

OFF

ON

OFF

ON

OFF

Economy 7

0

12:30am 

6:30am

1:30am

7:30am

1

11:30pm

7:30am

12:30am

8:30am

2

10:00pm

8:30am

11:00pm

9:30am

3

10:30pm 12:30am

2:30am

7:30am

11:30pm

1:30am

3:30am

8:30am

Eco 20:20

4

9:00pm

7:00am

10:00pm

8:00am

Economy 10

5

12:00am

7:00am

2:00pm

5:00pm

7:00pm

10:00pm

12:00am

7:00am

2:00pm

5:00pm

7:00pm

10:00pm

6

2:00am

7:00am

2:00pm

4:00pm

7:00pm

10:00pm

2:00am

7:00am

2:00pm

4:00pm

7:00pm

10:00pm

7

12:00am

5:00am

1:00pm

4:00pm

8:00pm

10:00pm

12:00am

5:00am

1:00pm

4:00pm

8:00pm

10:00pm

8

4:30am

7:30am

1:30pm

4:30pm

8:30pm

12:30am

4:30am

7:30am

1:30pm

4:30pm

8:30pm

12:30am

This preset MUST be adjusted or the unit will remain permanently ON

9

12:00am

8:00am

8:00am

4:00pm

4:00pm

12:00am

12:00am

8:00am

8:00am

4:00pm

4:00pm

12:00am