 Features:

1

 Operation Guide:

2

CHPPR3 is a three channel programmer, offering three completely

independent time controlled channels. Ideal for control of 2 

individual heating zones and separate hot water control.

24 hour, 5/2 day and 7 day selectable
2 or 3 ON/OFF periods selectable
1,2 or 3 hour boost
Advance to next programmed event
Automatic Summer/Winter time change
Factory set time & date
Program options-ON, OFF, All day or Auto
Large and clear to read illuminated display
With/without service interval functionality
Suitable for pumped heating systems
Standard wall plate - simple plug in and replace

2.1 

Open the front cover to show the hidden panel (as Fig. 1), and 

complete all the settings as per below operation guide.

2.2 Configuration:

When setting time, date or changing programme times the first 

screen displayed indicates the configuration as set up by the 

installer. 

The 24 hour, or 5 day/2day, or 7 day programming option as set up 

by the installer can also be verified at this stage by how the Monday 

to Sunday indicators are displayed.

2.6 Setting the Time:

Configuration

Display

2 ON / OFF Pumped System

2 PU

3 ON / OFF Pumped System

Times for Central Heating and Hot Water

can be independently set.

3 PU

A M

ON

ALL DAY

A M

Fig.2

Fig.3

Fig.4

If the unit is installed as a 24 hour programmer, the built in 

programme will be the same for each day (i.e. Sat-Sun be same as 

Mon-Fri above).

2.4 Factory Programme Settings:

2.3 Built in Programme:

For convenience, the programmer has a built in programme which 

will be satisfactory for many people, but which can be changed 

very easily (see section CHANGING PROGRAMME TIMES). Once 

the unit is powered up this built in programme will run.If the user 

changes from the built in programme and wishes to return to it, 

then pressing the reset button with a non metallic pointed tool will 

return the unit to the built in / default programme.

2.5 Selecting Operating Mode:

NOTE: Every time the reset is pressed, the time and date

must be set again. See the sections ‘Setting The Time & 

Setting The Date’.

1.

Press the SET button once. The configu-

ration setting will appear on the screen

see Fig.2

.

2. 

Press the SET button again. The clock 

icon [1] on the screen will flash(See Fig.3).

3. 

Press the +/- buttons to adjust the time. 

Time will change quicker if pressed 

continually.

4. 

Press SET once to move on to setting 

the DATE or press multiple times to return 

to RUN mode(Fig.4).

140mm

88

.6

m

m

A M

P M

ON OFF

2 3

1

DATE

ADV

ON   OFF

AUTO

ALL DAY

ADV

ON   OFF

AUTO

ALL DAY

1

2

ADV

ON   OFF

AUTO

ALL DAY

+ 1 H R
+ 2 H R
+ 3 H R

+ 1 H R
+ 2 H R
+ 3 H R

+ 1 H R
+ 2 H R
+ 3 H R

 <6>

+HR

ADV

+HR

ADV

+HR

ADV

1

2

1

2

COPY

DAY

SET

-

NEXT

+

RESET

ON
OFF
AUTO

ALL DAY

CHPPR3

CURRENT SETTINGS

Press 

SET

 in turn to show product Configuration

(Set by your installer) Time Date

Program times for each channel Normal display

( Press

 +/-

 to adjust,

NEXT 

to scroll date or program

times,

DAY

 to scroll program days & 

COPY 

to copy

programs into next day )

MODE SETTING

Press 

Mode

 button to select operating mode for a

channel

AUTO - Operate to the set programs

ON - Continuously ON

OFF - Continuously OFF

ALL DAY - On once between first ON and last OFF

ADVANCE ( AUTO / ALL DAY MODES)

Press 

ADV

 to switch a channel ON or OFF temporarily

until the next programme time

USING +HR ( NOT IN ON MODE)

Press 

+HR

 to select1,2 or 3 Hours.

When OFF - will boost for the time

When ON - will extend current program by time

E lite Security Products

Unit 7

T arget Park,

Shawbank Rd, Lakeside,

    R edditch, B98 8YN

T elephone:  01527 51 51 50

Fax:    01527 51 51 43

E mail:   [email protected]

W eb:   www.espuk.com

 <4>

 <3>

 <2>

 <1>

 <5>

Fig.1

Programming Option 

7 DAY

Mon to Sun lndicators flash

5 / 2 DAY

24 HOUR

Mon to sun individually shown

Mon to Fri together then Sat

& Sun together

Mon to sun together shown

1st ON

2 PU

3 PU

Mon - Fri

Sat - Sun

1st OFF

-
-

2nd ON

2nd OFF

1st ON

1st OFF

2nd ON

2nd OFF

3rd ON

3rd OFF

6:00am
8:30am

12:00 noon
12:00 noon

4:30 pm

10:30 pm

7:00am
9:00am

12:00 noon
12:00 noon

4:30 pm

11:30 pm

ON

AUTO

Central Heating and Hot Water is ON

continuously

ALL

DAY

OFF

Central Heating and Hot Water will be switched

Central Heating and Hot Water will be switched

ON only once each day between the first ON

time and last OFF time

Central Heating and Hot Water is OFF continuously

ON or OFF as programmed

1

2

ON
OFF

AUTO
ALL DAY

You can review or edit the date you have set 

just by pressing NEXT button again and 

repeating the sequence above. To confirm 

the date and move on to PROGRAM 

mode,press SET button once or press SET 

button multiple times to return to RUN mode.

2.7 Setting the Date:

The built in programme can easily be changed to better suit your 

lifestyle.

1.

Press SET button until radiator icon [3] flashes in the display and 

1 ON [4] appears.This indicates the time shown on the display is 

the first ON time(see Fig.8).

2. 

By pressing the +/- buttons you can alter the ON time to the time you 

want.

3. 

Press NEXT button, display will now show 1 OFF [4]. 

4. 

By pressing the +/- buttons you can alter the OFF time to the 

time you want(see Fig.9).

5. 

Press NEXT button to access remaining ON/OFF periods and 

alter in same manner as above.

6. 

To return to RUN mode, press the SET button until the display 

return to run mode(Fig.4)

2.8 Change Central Heating Times:

DATE

DATE

DATE

Fig.6

Fig.5

Fig.7

A M

ON

1

A M

OFF

1

Fig.8

Fig.9

Press SET button until tap icon [3] flashes in the display and 1 ON 

[4] appears. This indicates the time shown on the display is the first 

ON time of hot water(see Fig.10) and proceed in same manner as 

‘To change the Central Heating Times’ above.

2.9 Change Hot Water Times:

If the unit is installed as a 7 day programmer, the initial programme 

displayed will be for Monday.You can go to any date of the week by 

pressing the DAY button repeatedly.

The ON/OFF times can be changed for each day as described 

above in the section “CHANGING PROGRAMME TIMES”.

If you press the COPY button, the current programme will be 

copied onto the next day.

7 Day Programmer Option:

Press the reset button with a non-metallic pointed tool to restore 

the built in programme.As well as restoring the built in programme, 

it also resets the time to 12:00pm and the date to 01/01/2020.

Initially the display shows all segments lit for a few seconds, but 

then will show the current configuration. See ‘Setting The Time’ 

section to continue.

As a safety feature, after reset the unit will be in OFF operating 

mode. Reselect your required operating mode.

The ADVANCE function allows the user to move to the next ON or 

OFF programme for a “one off” event, without having to change the 

programme or change the operating mode.

Press the Hot Water channel ADV button. This will turn the Hot 

Water ON if it is in an OFF period and OFF if it is in an ON period. 

It will stay in this state until either ADV button is pressed again, or 

until a programmed ON/OFF period commences. The word ADV 

[5] will appear in the tleft of the LCD.

Warning:The ADVANCE function is only available when 

programme is in AUTO or ALL DAY operating modes.

NOTE

Programming is in 10 minute segments.

NOTE: it is not possible to copy Sunday to Monday.

1.

Press the SET button until the Y:XX icon

year

appears and the D

DATE

icon [2] 

flashes

see Fig.5

.

2.

Press the +/- button to set the year.

3.

Press NEXT button. M:XX appears

month

)(

see Fig.6

.

4.

Press +/- button to set month.

5.

Press NEXT button. D:XX appears

Day)

see Fig.6

.

6.

Press +/- button to set day.

2.11 Reset:

 2.12 Using Advance:

 To Advance Central Heating:

Press the appropriate Central Heating channel ADV button. This 

will turn the Central heating ON if it is in an OFF period and OFF if 

it is in an ON period. It will stay in this state until either ADV button 

is pressed again, or until a programmed ON/OFF period 

commences. The word ADV [5] will appear in the left hand of the 

LCD.

To Advance Central Heating 1 or 2:

If the unit is installed as a 24 hour programmer, the built in 

programme will be the same for each day.

The COPY & DAY buttons have no affect if installed as a 24 hour 

programmer.

The unit will automatically return to normal running mode if a period 

of 30 seconds passes without any buttons being pressed.

Programming past midnight is NOT allowed. To overcome this the 

program needs to be split in two parts from midnight as per 

example-
Desired program period - on 10:00pm off 7:00am

make Prog 1 - on 12:00am off 7:00am

make Prog 2 - on 10:00pm off 12:00am

2.10 Programming Notes:

If the unit is installed as a 5 day/2 day programmer, the initial 

programme displayed will be for Monday to Friday. 

Pressing the DAY button will take you to the programme for Satur-

day and Sunday.

The ON/OFF times can be changed for each day group as 

described above in the section “CHANGING PROGRAMME 

TIMES”.

If you press COPY button, the current programme will be copied 

onto the next day group.