1
CHPPR3
3 Channel Prog
User Instructions
rammer
The latest ESP product manuals
can be found on-line:
Features:
1
Operation Guide:
2
CHPPR3 is a three channel programmer, offering three completely
independent time controlled channels. Ideal for control of 2
individual heating zones and separate hot water control.
24 hour, 5/2 day and 7 day selectable
2 or 3 ON/OFF periods selectable
1,2 or 3 hour boost
Advance to next programmed event
Automatic Summer/Winter time change
Factory set time & date
Program options-ON, OFF, All day or Auto
Large and clear to read illuminated display
With/without service interval functionality
Suitable for pumped heating systems
Standard wall plate - simple plug in and replace
2.1
Open the front cover to show the hidden panel (as Fig. 1), and
complete all the settings as per below operation guide.
2.2 Configuration:
When setting time, date or changing programme times the first
screen displayed indicates the configuration as set up by the
installer.
The 24 hour, or 5 day/2day, or 7 day programming option as set up
by the installer can also be verified at this stage by how the Monday
to Sunday indicators are displayed.
2.6 Setting the Time:
Configuration
Display
2 ON / OFF Pumped System
2 PU
3 ON / OFF Pumped System
Times for Central Heating and Hot Water
can be independently set.
3 PU
A M
ON
ALL DAY
A M
Fig.2
Fig.3
Fig.4
If the unit is installed as a 24 hour programmer, the built in
programme will be the same for each day (i.e. Sat-Sun be same as
Mon-Fri above).
2.4 Factory Programme Settings:
2.3 Built in Programme:
For convenience, the programmer has a built in programme which
will be satisfactory for many people, but which can be changed
very easily (see section CHANGING PROGRAMME TIMES). Once
the unit is powered up this built in programme will run.If the user
changes from the built in programme and wishes to return to it,
then pressing the reset button with a non metallic pointed tool will
return the unit to the built in / default programme.
2.5 Selecting Operating Mode:
NOTE: Every time the reset is pressed, the time and date
must be set again. See the sections ‘Setting The Time &
Setting The Date’.
1.
Press the SET button once. The configu-
ration setting will appear on the screen
(
see Fig.2
)
.
2.
Press the SET button again. The clock
icon [1] on the screen will flash(See Fig.3).
3.
Press the +/- buttons to adjust the time.
Time will change quicker if pressed
continually.
4.
Press SET once to move on to setting
the DATE or press multiple times to return
to RUN mode(Fig.4).
140mm
88
.6
m
m
A M
P M
ON OFF
2 3
1
DATE
ADV
ON OFF
AUTO
ALL DAY
ADV
ON OFF
AUTO
ALL DAY
1
2
ADV
ON OFF
AUTO
ALL DAY
+ 1 H R
+ 2 H R
+ 3 H R
+ 1 H R
+ 2 H R
+ 3 H R
+ 1 H R
+ 2 H R
+ 3 H R
<6>
+HR
ADV
+HR
ADV
+HR
ADV
1
2
1
2
COPY
DAY
SET
-
NEXT
+
RESET
ON
OFF
AUTO
ALL DAY
CHPPR3
CURRENT SETTINGS
Press
SET
in turn to show product Configuration
(Set by your installer) Time Date
Program times for each channel Normal display
( Press
+/-
to adjust,
NEXT
to scroll date or program
times,
DAY
to scroll program days &
COPY
to copy
programs into next day )
MODE SETTING
Press
Mode
button to select operating mode for a
channel
AUTO - Operate to the set programs
ON - Continuously ON
OFF - Continuously OFF
ALL DAY - On once between first ON and last OFF
ADVANCE ( AUTO / ALL DAY MODES)
Press
ADV
to switch a channel ON or OFF temporarily
until the next programme time
USING +HR ( NOT IN ON MODE)
Press
+HR
to select1,2 or 3 Hours.
When OFF - will boost for the time
When ON - will extend current program by time
E lite Security Products
Unit 7
,
T arget Park,
Shawbank Rd, Lakeside,
R edditch, B98 8YN
T elephone: 01527 51 51 50
Fax: 01527 51 51 43
E mail: [email protected]
W eb: www.espuk.com
<4>
<3>
<2>
<1>
<5>
Fig.1
Programming Option
7 DAY
Mon to Sun lndicators flash
5 / 2 DAY
24 HOUR
Mon to sun individually shown
Mon to Fri together then Sat
& Sun together
Mon to sun together shown
1st ON
2 PU
3 PU
Mon - Fri
Sat - Sun
1st OFF
-
-
2nd ON
2nd OFF
1st ON
1st OFF
2nd ON
2nd OFF
3rd ON
3rd OFF
6:00am
8:30am
12:00 noon
12:00 noon
4:30 pm
10:30 pm
7:00am
9:00am
12:00 noon
12:00 noon
4:30 pm
11:30 pm
ON
AUTO
Central Heating and Hot Water is ON
continuously
ALL
DAY
OFF
Central Heating and Hot Water will be switched
Central Heating and Hot Water will be switched
ON only once each day between the first ON
time and last OFF time
Central Heating and Hot Water is OFF continuously
ON or OFF as programmed
1
2
ON
OFF
AUTO
ALL DAY
You can review or edit the date you have set
just by pressing NEXT button again and
repeating the sequence above. To confirm
the date and move on to PROGRAM
mode,press SET button once or press SET
button multiple times to return to RUN mode.
2.7 Setting the Date:
The built in programme can easily be changed to better suit your
lifestyle.
1.
Press SET button until radiator icon [3] flashes in the display and
1 ON [4] appears.This indicates the time shown on the display is
the first ON time(see Fig.8).
2.
By pressing the +/- buttons you can alter the ON time to the time you
want.
3.
Press NEXT button, display will now show 1 OFF [4].
4.
By pressing the +/- buttons you can alter the OFF time to the
time you want(see Fig.9).
5.
Press NEXT button to access remaining ON/OFF periods and
alter in same manner as above.
6.
To return to RUN mode, press the SET button until the display
return to run mode(Fig.4)
2.8 Change Central Heating Times:
DATE
DATE
DATE
Fig.6
Fig.5
Fig.7
A M
ON
1
A M
OFF
1
Fig.8
Fig.9
Press SET button until tap icon [3] flashes in the display and 1 ON
[4] appears. This indicates the time shown on the display is the first
ON time of hot water(see Fig.10) and proceed in same manner as
‘To change the Central Heating Times’ above.
2.9 Change Hot Water Times:
If the unit is installed as a 7 day programmer, the initial programme
displayed will be for Monday.You can go to any date of the week by
pressing the DAY button repeatedly.
The ON/OFF times can be changed for each day as described
above in the section “CHANGING PROGRAMME TIMES”.
If you press the COPY button, the current programme will be
copied onto the next day.
7 Day Programmer Option:
Press the reset button with a non-metallic pointed tool to restore
the built in programme.As well as restoring the built in programme,
it also resets the time to 12:00pm and the date to 01/01/2020.
Initially the display shows all segments lit for a few seconds, but
then will show the current configuration. See ‘Setting The Time’
section to continue.
As a safety feature, after reset the unit will be in OFF operating
mode. Reselect your required operating mode.
The ADVANCE function allows the user to move to the next ON or
OFF programme for a “one off” event, without having to change the
programme or change the operating mode.
Press the Hot Water channel ADV button. This will turn the Hot
Water ON if it is in an OFF period and OFF if it is in an ON period.
It will stay in this state until either ADV button is pressed again, or
until a programmed ON/OFF period commences. The word ADV
[5] will appear in the tleft of the LCD.
Warning:The ADVANCE function is only available when
programme is in AUTO or ALL DAY operating modes.
NOTE
:
Programming is in 10 minute segments.
NOTE: it is not possible to copy Sunday to Monday.
1.
Press the SET button until the Y:XX icon
(
year
)
appears and the D
(
DATE
)
icon [2]
flashes
(
see Fig.5
)
.
2.
Press the +/- button to set the year.
3.
Press NEXT button. M:XX appears
(
month
)(
see Fig.6
)
.
4.
Press +/- button to set month.
5.
Press NEXT button. D:XX appears
(
Day)
(
see Fig.6
)
.
6.
Press +/- button to set day.
2.11 Reset:
2.12 Using Advance:
To Advance Central Heating:
Press the appropriate Central Heating channel ADV button. This
will turn the Central heating ON if it is in an OFF period and OFF if
it is in an ON period. It will stay in this state until either ADV button
is pressed again, or until a programmed ON/OFF period
commences. The word ADV [5] will appear in the left hand of the
LCD.
To Advance Central Heating 1 or 2:
If the unit is installed as a 24 hour programmer, the built in
programme will be the same for each day.
The COPY & DAY buttons have no affect if installed as a 24 hour
programmer.
The unit will automatically return to normal running mode if a period
of 30 seconds passes without any buttons being pressed.
Programming past midnight is NOT allowed. To overcome this the
program needs to be split in two parts from midnight as per
example-
Desired program period - on 10:00pm off 7:00am
make Prog 1 - on 12:00am off 7:00am
make Prog 2 - on 10:00pm off 12:00am
2.10 Programming Notes:
If the unit is installed as a 5 day/2 day programmer, the initial
programme displayed will be for Monday to Friday.
Pressing the DAY button will take you to the programme for Satur-
day and Sunday.
The ON/OFF times can be changed for each day group as
described above in the section “CHANGING PROGRAMME
TIMES”.
If you press COPY button, the current programme will be copied
onto the next day group.
5/2 Day Programmer Option:
24 Hour Programmer Option:
P M
ON
1
Fig.10