2
Health & Safety
Regulations.
proceeding.
may be subject to change without prior notice.
Health & Safety
This unit must be installed by a suitably qualified person in accordance with the latest IEE Wiring
Regulations.
Isolate mains supply before commencing installation. Please read all installation instructions before
proceeding.
Example circuit diagrams for typical installations are shown. These diagrams are schematic and should
be used as a guide only. Please ensure that all installations comply with the current IEE regulations. For
reasons of space and clarity not every system has been included and the diagrams have been simplified,
for instance some Earth connections have been omitted. Other control components shown in the
diagrams i.e. Valves, Room Stats etc. are general representations only. However, the wiring detail can
be applied to the corresponding models of most manufacturers.
Your product is not user serviceable. Do not dismantle this product.
Due to our policy of continuous product improvement and development, the specifications in this guide
may be subject to change without prior notice.
Elite Security Products
Unit 7, Target Park, Shawbank Road,
Lakeside, Redditch, B98 8YN
Tel: 01527 515150
Fax: 01527 515143
Email: [email protected]
Web: www.espuk.com
If the Central heating operating mode is OFF, then it will switch on
for the extra hours selected. If the Central heating mode is AUTO
or ALL DAY, then during an OFF period,it will switch on for the
extra hours selected. If during an ON period, then it will temporarily
extend that programme by the number of hours selected.
Warning: The +HOUR function is only available when
programme is in AUTO,ALL DAY or OFF operating
modes.
Warning: The +HOUR function is only available when
programme is in AUTO,ALL DAY or OFF operating modes.
Press the Central Heating cHR button to make the desired
selection with one,two or three hours extra heating [6] and cancel
options offered.
2.13 Using +HR Boost:
For +Hr Central Heating:
Press the Hot Water cHR button to make the desired selec-
tion with one, two or three hours extra heating [6] and cancel options
offered.
For +Hr Hot Water:
A visual warning message 15, rUn, SEr, dUE indicates the
installer has set the programmer for a Partial Shutdown and your
heating/hot water will operate for a random15 minute portion of
each programmed hour only Therefore, to ensure your comfort
level is maintained, it is important to respond to any requests for a
gas safety check/boiler service appointment and to keep to the
appointment. Contact details for the installer/landlord may be
shown on a Service Contact label affixed to the product. The
installer will cancel or reset the Service Interval Timer as part of the
safety check/ boiler service.
2.16 Service Interval Function Setting:
If you are a tenant, under The Gas Safety (Installation & Use)
Regulations 1998, your private landlord, local authority or hous-
ing association must carry out a 12 monthly gas safety check to
make sure gas fittings and appliances are safe to use.
2.15 Power Interruption :
In the event of a mains supply failure, the screen will go blank, but
the programmer continues to keep the time and retain your stored
programme.
When power is restored, if there has been no change to the rear
DIP switch, the programmer returns to its expected operating
condition.
If the configuration setting on the rear DIP switch has been altered
during the power interruption, the screen will initially show the new
configuration. And the appropriate factory default programme (see
BUILT IN PROGRAMME section) will be installed.
Press SET button to return to RUN mode.
The display backlight will also flash on and off from 7 days prior to
the boiler service due date. During this warning period, the
programmer will continue to operate normally and you have full
access to all its features.
If the boiler is not serviced within the 28 days then the programmer
will operate only according to one of two settings (selected by the
installer on installation). All buttons will be disabled. The display
backlight will continue to flash.
A visual warning message OFF, SEr, dUE indicates the installer
has set the programmer for a Total Shutdown and your heating/hot
water will no longer operate.
If set by the installer, 28 days prior to the boiler service due date, a
rotating visual warning message SEr, dUE, dXX will remind you
that a service is due (XX shows the number of days remaining in
the warning period).
Warning: The Holiday function is only available in AUTO,
ALL DAY or ON operating modes.
The number of days will decrease at midnight each day.
The +HR boost override can be used during a holiday period.
1.
Press & Hold DAY button for 4 seconds to enter the holiday
function , d:01 flashes(see Fig. 12).
2.
Press +/- button to set the holiday days.
3.
Press DAY button to activate.
4.
Press & Hold DAY button for 4 seconds to cancel a holiday
period.
2.14 Holiday Mode:
The Holiday function allows the user to turn all channels to the OFF
operating mode, for a settable amount of days from 01-99 days.
During this function, a suitcase icon will be displayed(see Fig 11).
If the Hot Water operating mode is OFF, then it will switch on for
the extra hours selected.
If the Hot Water mode is AUTO or ALL DAY, then during an OFF
period, it will switch on for the extra hours selected. If during an ON
period, then it will temporarily extend that programme by the
number of hours selected.
NOTE: If the programmer is in the OFF mode and then +HR
button is pressed (+1 HR, +2 HR, or + 3 HR) and the
resulting time of the boost overlaps a START / ON time in
the AUTO mode programme memory,then the boost will
disengage. If this happens simply press +HR button again
and then it will temporarily extend that programme by the
number of hours selected.
Fig.12
P M
OFF
Fig.11
Date Issued
J20
A30-CHPPR2-01-2
Rev.1
Issue No
Description