Table 2: Environmental Conditions
Operating
0°C to +60°C (32°F~140°F) operating temperature (forced cooling).
It is the customer’s responsibility to provide sufficient airflow around each of the
components to keep them within allowed temperature range. Please refer to the thermal
simulation report for information about airflow.
10% to 90% relative humidity (non-condensing)
Storage
-20°C~70°C (-4°F~176°F); lower limit of storage temperature is defined by specification
restriction of on-board CR2032 battery.
Board with battery has been verified for storage temperature down to -40
C by Kontron.
Up to 95
% relative humidity (temperature 25°C to 30°C)
Radiated Emissions
(EMI)
All Peripheral interfaces intended for connection to external equipment are EMI protected.
EN 61000-6-4:2007 (EMC) Generic emission standard Part 6-4: Emission standard for
industrial environments
Safety
EN 60950-1:2006 +A11:2009 +A1:2010 +A12:2011:
Safety for information technology equipment including electrical business equipment
Shock
IAW IEC 60068-2-27, Half-sine wave, Acceleration: 2g, Pulse duration: 11ms, number of
shocks: 600 shocks (100 shocks for each face)
Vibration
AW IEC 60068-2-64, test Fh, Random Vibration, 90 min per axis, 3 axes at 1.9 grms, with
PSD: 10-20Hz: 0.05 g²/Hz and 20-500Hz:- 3dB/octave.
Restriction of
Hazardous
Substances (RoHS)
All boards in the mITX-SKL family are RoHS compliant
MTBF
15 years
Altitude
2000 m max., optionally 3000m
Table 3: Certification and Compliance Information
UL
E147705-A96-UL: Equipment Including Electrical Business Equipment
CE
EMC Directive 2014/30/EU
EN55032/EN55024
Low Voltage
Directive
2014/35/EU
FCC
FCC 47 CFR Part 15 Subpart B
ANSI C63.4:2014
ISED ICES-003 (Issue 6)
CE EMC
EN 55032:2012/AC:2013, Class B
CISPR 32:2012
EN 61000-3-2:2014
EN 61000-3-3:2013
EN 55024:2010 + A1:2015
FCC DoC
FCC 47 CFR Part 15 Subpart B
ICES-003 Issue 6-2016
ANSI C63.4-2014