Environmental Specification 

Table 7: Environmental Specification 

Environmental 

5-port 

8-port 

Operating Temperature 

-40°C to +75°C (cold startup at -40°C) 

Storage Temperature 

-40°C to +85°C 

Humidity  

5% to 95% RH (non-condensing) 

 

7.3.

 

Certifications 

Table 8: Certification Compliance 

Certification 

5-port 

8-port 

EMC 

EN 61000-6-3 Class B, EN 61000-6-4, EN 61000-6-2 and EN 55035 

Safety 

UL/IEC/EN 62368-1 

FCC 

According to requirements of 47 CFR FCC Part 15, Subpart B, Class A rules and 
regulations and ANSI C63.4: 2014 rules to limit the potential of harmful 
interference 

RoHS/WEEE/REACH 

RoHS (Pb free) / Compliant/ Compliant 

MTBF 

>200,000 hours 

 

7.4.

 

Mechanical Specification 

Table 9: Mechanical Specification 

Mechanical 

5-port 

8-port 

Dimensions  (H x W x D) 

90 mm x 25 mm x 70.2 mm 

90 mm x 40 mm x 80.9 mm 

Weight 

250 g 

265 g 

Protection 

IP30 

Installation 

DIN-Rail, Wall Mount  

 

Summary of Contents for Kontron KSwitch D2

Page 1: ...USER GUIDE www kontron com KSwitch D2 UF Unmanaged Fast Ethernet Switch Doc Preliminary User Guide Rev 0 9 Doc ID 1068 1426...

Page 2: ...KSwitch D2 UF Unmanaged Fast Ethernet Switch Preliminary User Guide Rev 0 9 www kontron com 2 This page has been intentionally left blank...

Page 3: ...warranty that such application will be suitable for the specified use without further testing or modification Kontron expressly informs the user that this user guide only contains a general descripti...

Page 4: ...Applications is entirely at your risk To minimize the risks associated with your products and applications you should provide adequate design and operating safeguards You are solely responsible for co...

Page 5: ...acts by visiting https www kontron com support and services kontron europe and asia support contact support Customer Service As a trusted technology innovator and global solutions provider Kontron ext...

Page 6: ...indicated and or prescribed by the law may endanger your life health and or result in damage to your material ESD Sensitive Device This symbol and title informs that the electronic boards and their c...

Page 7: ...n of piggybacks Serious electrical shock hazards can exist during all installation repair and maintenance operations on this product Therefore always unplug the power cable and any other cables which...

Page 8: ...circuits and damage the batteries or conductive circuits on the product Lithium Battery Precautions If your product is equipped with a lithium battery take the following precautions when replacing the...

Page 9: ...ponents used are capable of being recycled Final disposal of this product after its service life must be accomplished in accordance with applicable country state or local laws or regulations WEEE Comp...

Page 10: ...s 14 3 Shipment and Packaging 15 3 1 Packaging 15 3 2 Unpacking 15 3 3 Scope of Delivery 15 3 4 Accessories 15 3 5 Product Identification Type Label 17 4 Features 18 4 1 Faceplate Features 19 4 1 1 RJ...

Page 11: ...on Compliance 28 Table 9 Mechanical Specification 28 Table 10 Electrical Specification 30 Table 11 List of Acronyms 34 List of Figures Figure 1 Type Label 17 Figure 2 KSwitch D2 UF Unmanaged Fast Ethe...

Page 12: ...on of this user guide visit Kontron s KSwitch Industrial Ethernet Switches at https www kontron com products systems ethernet solutions This user guide provides an overview of the switch s features an...

Page 13: ...Power Source LPS and Power Source PS2 of UL IEC 62368 1 Only products or parts that meet the requirements for Power Source PS1 of UL IEC 62368 1 may be connected to the product s available interfaces...

Page 14: ...devices or micro circuitry Proper packaging and grounding techniques are necessary precautions to prevent ESD damage Always take the following precautions 1 Transport ESD sensitive parts in ESD safe c...

Page 15: ...important information for handling the switch 5 Check the contents for visible shipping damage If you notice any shipping damage or inconsistencies between the contents and the original order contact...

Page 16: ...inary User Guide Rev 0 9 www kontron com 16 Product Name Description RK4U 19 Rack Mount Kit 4U Enables DIN Rail switches to be installed in a 4U rack WK25 Wall Mount Kit 2x wall mount plates and screw...

Page 17: ...kontron com 17 3 5 Product Identification Type Label Figure 1 Type Label 1 Model full name 2 Series name 3 Part Number PN with bar code 4 Revision 5 Serial Number SN with barcode 6 Production date 7 E...

Page 18: ...witch D2 UF is an unmanaged industrial Ethernet switches with up to eight fast Ethernet ports providing easy to use plug n play connectivity Figure 2 KSwitch D2 UF Unmanaged Fast Ethernet Switch Key f...

Page 19: ...nd when connecting to an Ethernet device use UTP Unshielded Twisted Pair or STP Shielded Twisted Pair Ethernet cables Depending on the switch variant the switch supports five or eight 10 100 Mbps RJ45...

Page 20: ...for faultfinding The Ethernet indicator LEDs are contained within the RJ45 connectors The power indictor LEDs are located on the switch s top side Figure 4 Indicator LED Ethernet 5 port and 8 port Tab...

Page 21: ...ch supports fault alarm notification for power To check for correct operation refer to the power indicator LEDs Figure 5 Power Contacts 5 port and 8 port 1 P1 contact 2 P2 contact When connecting the...

Page 22: ...ire to the switch ensure that the wire size range is 18 to 14 AWG and resistance is less than 5 ohms Ground properly using a ground that meets the ground requirements specified in your local national...

Page 23: ...ed or does not have supply power 4 3 Rear Side Features The mounting holes for the DIN Rail clip enable the orientation of the DIN Rail clip to be changed by 180 Sets of mounting holes at the top and...

Page 24: ...Mounting To mount the switch on a DIN Rail perform the following 1 Fasten the DIN Rail clip to the switch in the upper position for the required mount orientation Figure 9 using the two screws provide...

Page 25: ...op of the wall mount plate is 27 mm To install the wall mount plates supplied in the Wall Mount Kit perform the following 1 Make sure the mounting surface is clean and smooth and meets the thickness r...

Page 26: ...n sites ground meets the grounding requirements specified in your local national and international region If access to power is restricted guarantee disconnection using a separate cut off device To co...

Page 27: ...r RJ45 Ports Up to 5x 10 100Mbsp Up to 8x 10 100Mbsp RJ45 Copper Ports Speed 10 100Mbps MDI MDIX Auto crossover Support straight or cross wired cables Auto negotiation Duplex 10 100 Mbps speed auto ne...

Page 28: ...tification 5 port 8 port EMC EN 61000 6 3 Class B EN 61000 6 4 EN 61000 6 2 and EN 55035 Safety UL IEC EN 62368 1 FCC According to requirements of 47 CFR FCC Part 15 Subpart B Class A rules and regula...

Page 29: ...KSwitch D2 UF Unmanaged Fast Ethernet Switch Preliminary User Guide Rev 0 9 www kontron com 29 Figure 12 Mechanical Dimensions 5 port Figure 13 Mechanical Dimensions 8 port...

Page 30: ...ng requirements specified in your local national international region The DC power supply must be connected to a well fused power source If access to power is restricted guarantee disconnection using...

Page 31: ...er serviceable parts Maintenance or repair on the switch may only be carried out by qualified personnel authorized by Kontron Return the switch to Kontron for maintenance and repair see Chapter 9 1 Re...

Page 32: ...ed warranty period Follow these steps before returning any product to Kontron 1 Visit the RMA Information website http www kontron com support and services support rma information Download the RMA Req...

Page 33: ...tatutory accident liability obligations in the event of damage caused to the product due to failure to observe the following General safety instructions for IT equipment within this user guide Warning...

Page 34: ...e LPS Limited Power Source MAC Media Access Control MDI Medium Dependent Interface MDIX Medium Dependent Interface cross over MIB Management Information Base MLD Multicast Listener Discovery MSTI Mult...

Page 35: ...Industry 4 0 applications With its standard products and tailor made solutions based on highly reliable state of the art embedded technologies Kontron provides secure and innovative applications for a...

Reviews: