background image

KSwitch D2 UG Unmanaged Gigabit Ethernet Switch - Preliminary User Guide, Rev. 0.9 

 

www.kontron.com 

 

// 9 

 

Quality and Environmental Management 

Kontron aims to deliver reliable high-end products designed and built for quality, and aims to complying with 
environmental laws, regulations, and other environmentally oriented requirements. For more information regarding 
Kontron’s quality and environmental responsibilities, visit http://www.kontron.com/about-kontron/corporate-
responsibility/quality-management. 

Disposal and Recycling 

Kontron’s products are manufactured to satisfy environmental protection requirements where possible. Many of the 
components used are capable of being recycled. Final disposal of this product after its service life must be 
accomplished in accordance with applicable country, state, or local laws or regulations. 

 

WEEE Compliance 

The Waste Electrical and Electronic Equipment (WEEE) Directive aims to: 

 

Reduce waste arising from electrical and electronic equipment (EEE) 

 

Make producers of EEE responsible for the environmental impact of their products, especially when the product 
become waste 

 

Encourage separate collection and subsequent treatment, reuse, recovery, recycling and sound environmental 
disposal of EEE  

 

Improve the environmental performance of all those involved during the lifecycle of EEE 

 

 

 

Environmental protection is a high priority with Kontron.  
Kontron follows the WEEE directive 
You are encouraged to return our products for proper disposal.

 

Summary of Contents for kontron KSwitch D2 UG

Page 1: ...USER GUIDE www kontron com KSwitch D2 UG Unmanaged Gigabit Ethernet Switch Doc Preliminary User Guide Rev 0 9 Doc ID 1068 1427...

Page 2: ...KSwitch D2 UG Unmanaged Gigabit Ethernet Switch Preliminary User Guide Rev 0 9 www kontron com 2 This page has been intentionally left blank...

Page 3: ...or warranty that such application will be suitable for the specified use without further testing or modification Kontron expressly informs the user that this user guide only contains a general descri...

Page 4: ...k Applications is entirely at your risk To minimize the risks associated with your products and applications you should provide adequate design and operating safeguards You are solely responsible for...

Page 5: ...contacts by visiting https www kontron com support and services kontron europe and asia support contact support Customer Service As a trusted technology innovator and global solutions provider Kontron...

Page 6: ...ns indicated and or prescribed by the law may endanger your life health and or result in damage to your material ESD Sensitive Device This symbol and title informs that the electronic boards and their...

Page 7: ...on of piggybacks Serious electrical shock hazards can exist during all installation repair and maintenance operations on this product Therefore always unplug the power cable and any other cables which...

Page 8: ...use short circuits and damage the batteries or conductive circuits on the product Lithium Battery Precautions If your product is equipped with a lithium battery take the following precautions when rep...

Page 9: ...omponents used are capable of being recycled Final disposal of this product after its service life must be accomplished in accordance with applicable country state or local laws or regulations WEEE Co...

Page 10: ...14 2 3 Grounding Methods 14 3 Shipment and Packaging 15 3 1 Packaging 15 3 2 Unpacking 15 3 3 Scope of Delivery 15 3 4 Accessories 15 3 5 Product Identification Type Label 17 4 Features 18 4 1 Facepl...

Page 11: ...ironmental Specification 29 Table 7 Certification Compliance 29 Table 8 Mechanical Specification 29 Table 9 Electrical Specification 31 Table 10 List of Acronyms 35 List of Figures Figure 1 Type Label...

Page 12: ...ion of this user guide visit Kontron s KSwitch Industrial Ethernet Switches at https www kontron com products systems ethernet solutions This user guide provides an overview of the switch s features a...

Page 13: ...Power Source LPS and Power Source PS2 of UL IEC 62368 1 Only products or parts that meet the requirements for Power Source PS1 of UL IEC 62368 1 may be connected to the product s available interfaces...

Page 14: ...ing a connector attached to a broken fiber or an energized fiber 2 2 Electrostatic Discharge ESD A sudden discharge of electrostatic electricity can destroy static sensitive devices or micro circuitry...

Page 15: ...rtant information for handling the switch 5 Check the contents for visible shipping damage If you notice any shipping damage or inconsistencies between the contents and the original order contact Kont...

Page 16: ...85 EN SFP G ZX70 T 1 Gigabit SFP Modules 1000Base ZX single mode transceiver 80km 1550nm wide operating Temp 40 85 EN SFP G TX00 T 1 Gigabit SFP Modules 1000Base TX transceiver RJ45 connector 100m 40...

Page 17: ...w kontron com 17 3 5 Product Identification Type Label Figure 1 Type Label 1 Model full name 2 Series name 3 Part Number PN with bar code 4 Revision 5 Serial Number SN with barcode 6 Production date 7...

Page 18: ...UG series offers cost effective unmanaged industrial Ethernet switches with up to 10 Gigabit copper or fiber optics Ethernet ports providing easy to use plug n play connectivity Figure 2 KSwitch D2 UG...

Page 19: ...ernet cables Depending on the switch variant the switch supports six or eight 10 100 1000 Mbps RJ45 copper Ethernet ports and two Ethernet ports that are either 10 100 1000 Mbps RJ45 copper Ethernet p...

Page 20: ...ly have a LC style connector and are available with multimode single mode long haul for connections up to 80 km or special application transceivers For each fiber port there is a transmit TX and recei...

Page 21: ...re 5 Indicator LEDs Table 4 Indicator LED Overview LED Name Indicator Color Condition P1 P2 On Green P1 P2 power line has power Off P1 P2 power line disconnected or does not have supply power RJ45 Cop...

Page 22: ...switch supports fault alarm notification for power To check for correct operation refer to the power indicator LEDs Figure 6 Power Contacts 8 port 10 port 1 P1 contact 2 P2 contact When connecting th...

Page 23: ...com 23 4 2 2 Ground Connector The switch must be grounded properly using the ground connector for optimum system performance Figure 7 Ground Connector 8 port 10 port Ground properly using a ground th...

Page 24: ...he DIN Rail clip enable the orientation of the DIN Rail clip to be changed by 180 Sets of mounting holes at the top and bottom of the rear side enable installation of two wall mount plates For mountin...

Page 25: ...Mounting To mount the switch on a DIN Rail perform the following 1 Fasten the DIN Rail clip on the switch in the upper position for the required mount orientation Figure 9 using the two screws provid...

Page 26: ...top of the wall mount plate is 27 mm To install the wall mount plates supplied in the Wall Mount Kits perform the following 1 Make sure the mounting surface is clean and smooth and meets the thicknes...

Page 27: ...nect the ground cable to the ground connector and ensure that the installation sites ground meets the grounding requirements specified in your local national and international region If access to powe...

Page 28: ...0Mbps Up to 2x 100 1000Mbps RJ45 Copper Ports Speed Up to 10x 10 100 1000 Mbps MDI MDIX Auto crossover Support straight or cross wired cables Auto negotiation Duplex 10 100 1000 Mbps speed auto negoti...

Page 29: ...pliance Certification 8 port 10 port EMC EN 61000 6 3 Class B EN 61000 6 4 EN 61000 6 2 and EN 55035 Safety UL IEC EN 62368 1 FCC According to requirements of 47 CFR FCC Part 15 Subpart B Class A rule...

Page 30: ...KSwitch D2 UG Unmanaged Gigabit Ethernet Switch Preliminary User Guide Rev 0 9 www kontron com 30 Figure 12 Mechanical Dimensions 8 port 10 port...

Page 31: ...allation sites ground meets the grounding requirements specified in your local national and international region The DC power supply must be connected to a well fused power source To protect the switc...

Page 32: ...ser serviceable parts Maintenance or repair on the switch may only be carried out by qualified personnel authorized by Kontron Return the switch to Kontron for maintenance and repair see Chapter 9 1 R...

Page 33: ...ated warranty period Follow these steps before returning any product to Kontron 1 Visit the RMA Information website http www kontron com support and services support rma information Download the RMA R...

Page 34: ...statutory accident liability obligations in the event of damage caused to the product due to failure to observe the following General safety instructions for IT equipment within this user guide Warnin...

Page 35: ...ode LPS Limited Power Source MAC Media Access Control MDI Medium Dependent Interface MDIX Medium Dependent Interface cross over MIB Management Information Base MLD Multicast Listener Discovery MSTI Mu...

Page 36: ...Industry 4 0 applications With its standard products and tailor made solutions based on highly reliable state of the art embedded technologies Kontron provides secure and innovative applications for...