Maintenance and Prevention
Kontron systems only require minimal maintenance and care to maintain correct operation.
Wipe the product with a soft dry cloth if required
Remove persistent dirt using a soft, slightly damp cloth (only use a mild detergent).
Clean the air filter pad regularly (as often as necessary, depending on the environment)
10.1.
Cleaning the Filter Pad
The filter pad inserts into the filter pad holder at the front side of the fan assembly. The filter pad is soiled by
pollution within the operating environment. If heavily soiled the filter pad can cause excessive heating of the product
Kontron recommends cleaning the filter pad as often as necessary. It is possible to change the filter pad during the
operation of the product.
Figure 33: Front side with filter pad holder
1.
Front side of the KISS 2U Short V3
2.
Filter pad
3.
Filter pad holder with knurled screw
4.
Front access panel
5.
Fan assembly
Operation is permitted only with a functional fan assembly!
Replace a defective fan assemble only with an original fan assembly.
To replace the filter pad, proceed as follows:
1.
Open the front access panel, (Figure 33 pos. 4).
2.
Loosen the knurled screw (Figure 33, pos. 3) that secures the filter pad holder to the fan assembly in the
direction shown.
3.
Release the filter pad holder’s positioning latches from the positioning holes on the fan assembly (Figure 34,
pos. 3) by moving upwards and lifting out the filter pad holder.
4.
Remove the dirty filter pad (Figure 37), from the filter pad holder.
5.
Clean the filter pad as follows:
a.
Rinse the filter pad in water (up to approx. 40°C/104°F; with a mild commercial detergent).
b.
It is also possible to beat the filter pad, suction clean the filter pad, or blast the filter pad with
warm compressed air.
c.
If the filter pad is soiled with grease and dust, rinse the filter pad in warm water with a degreaser.
d.
Do not clean the filter pad with a piercing jet of water.