KBox A-203-sXAL4 – User Guide Preliminary Rev. 0.2
// 46
10/
Standard Interfaces – Pin Assignments
10.1.
External interfaces
Low-active signals are indicated by a minus sign.
10.1.1.
(X101) Power Input Connector
Table 7: (X101) Power Input Connector
If any of the supply voltages drops below the allowed operating level longer than the
specified hold-up time, all the supply voltages should be shut down and left OFF for a time
long enough to allow the internal board voltages to discharge sufficiently.
If the OFF time is not observed, parts of the board or attached peripherals may work
incorrectly or even suffer a reduction of MTBF.
The minimum OFF time depends on the implemented PSU model and other electrical factors
and needs to be measured individually for each case.
10.1.2.
(X106 as ETH 1 and X107 as ETH 2) Ethernet Connectors
Table 8: (X106, X107) Ethernet Connectors
Speed (Mbps)
LINK/ACT
LINK
ACTIVE
10
off
on
orange on (blinking)
100
green
on
orange on (blinking)
1000
orange
on
orange on (blinking)
Pin
Signal Name
2-pin POWER SUBCON (male)
1
+24 VDC (input)
2
0V (input )
Pin
Signal Name
ETH1, ETH2 (RJ45)
1
MDI0+
2
MDI0-
3
MDI1+
4
MDI2+
5
MDI2-
6
MDI1-
7
MDI3+
8
MDI3-
X106
X107