background image

OVERLOAD

 

  PROTECTOR

 

 

10. Troubleshooting: 

Item 

Trouble 

Cause 

Step for Solution 

1. Air supply was closed. 

Open the air supply. 

2. Exchange valve 

37

 

caught by fur. Disassemble the pump for 

cleaning then smear the grease. 

3. Spring 

13

 

broke. 

Change the spring   

4. Spool 

11

 

caught. 

Check if any damage happens 

from the oil seal 

26

 

and spool 

11

.   

Ⅰ  Pump not work 

5. Air pressure is too low or not 

enough. 

Adjust the air pressure to over 3 

kgf/cm

2

 

1. Exchange valve 

37

 

caught by fur.  Disassemble the pump for 

cleaning then smear the grease. 

Ⅱ  Air leak from the 

pump 

2. The O-ring 

10

 

of the exchange 

valve was damaged.   

Change the O-ring. 

1. Oil seal 

26

 

damaged. 

Change the oil seal. 

The 
pump 

2. Inlet

 

valve

  ○

20

damaged or caught.  Check if any damage happens 

from the inlet base  ○

24

  and inlet 

valve  ○

20

3. Without enough oil in the oil tank. 

Refill hydraulic oil,and let the air 

drain. 

4. Pilot valve 

29

  caught. 

Check if any damage happens 

from the pilot valve

.

 

Ⅲ  Pump   

nonstop 
(highest 
speed) 

The 

overload 

valve 

5. Air drain bolt 

40

 

loosen. 

Fasten the air drain bolt. 

Piping 

1. Oil leak out from outer piping. 

Find out the leakage position then 

fasten it.   

2. Inlet valve

  ○

20

 

damaged. 

Check if any damage happens 

from the inlet base  ○

24

  and inlet 

valve  ○

20

The pump 

3. The pressure valve automatically 

adjusts pressure due to the air 

pressure is too high now.   

Adjust the air pressure to lower 

than 5 kgf/cm

2

4. O-Ring 

36

 

damaged. 

Change the O-ring. 

5. Pressure control valve 

27

   

damaged. 

Change the pressure control 

valve. 

Ⅳ 

Pump   

nonstop 

(lower 

speed) 

The 

overload 

valve 

6. Air drain bolt  ○

40

  not lock. 

Fasten the air drain bolt. 

 

2006.12.04

                                                                                     

SANDSUN

                                         

Summary of Contents for VA08H Series

Page 1: ...L VA08H Air Pressure Type SANDSUN PRECISION MACHINERY CO LTD T e l 8 8 6 4 8 5 3 6 6 8 8 F a x 8 8 6 4 8 5 3 6 6 9 9 http www sandsun com tw E mail sandsun ms26 hinet net 57 7 NO 7 LANE 57 SEC 3 CHUNG...

Page 2: ...1 4 BASIS OF SELECTION 2 5 ATTENTION POINTS FOR PIPING 2 6 CAUTION IN USE 3 7 METHOD OF AIR DRAIN 3 8 WORKING PRINCIPLE 4 9 SETTING METHOD OF LIMIT SWITCH 5 10 TROUBLESHOOTING 6 11 PUMP ASSEMBLY DIAGR...

Page 3: ...ch can prevent effects of excessive rising of hydraulic pressure caused by raised temperature when press is operating 2 Selection of Model V A 0 8 H 1 2 3 Suitable for press 200 tons down Setting rang...

Page 4: ...according to releasing flow rate of cylinder inside slide Q Releasing flow rate of overload protector which you choose has to be more than of cylinder inside slide when overload occurs Please consider...

Page 5: ...king 7 1 3 Wait for around 20 seconds in order to exhaust air completely 7 1 4 Turn the air drain bolt clockwise to fasten it and then pump stops working hydraulic pressure is raising 7 1 5 If the pum...

Page 6: ...ly and the air solenoid valve which is used by overload protector will be OFF cut off the power supply 8 3 After overload protector was released or hydraulic pressure isn t enough After overload occur...

Page 7: ...thickness gauge of 0 8 1 0 mm each between adjustable screw and head of limit switch to adjust limit switch After adjustable screw please fasten the nut and then insert the thickness gauge to re confi...

Page 8: ...ught Check if any damage happens from the inlet base 24 and inlet valve 20 3 Without enough oil in the oil tank Refill hydraulic oil and let the air drain 4 Pilot valve 29 caught Check if any damage h...

Page 9: ...Filter Exchange valve Check ring Silencer plate Buffer pad SANDSUN 1 1 1 1 1 1 1 1 Spring 39 41 42 40 Bolt Cover Silencer 37 38 35 36 M6x90 61 2800 61 2400 61 2500 R 45 61 2600 61 2700 61 5700 Inlet v...

Page 10: ...1 1 61 7100 AS 46 AS 24 61 1400 TM14x30 AT11 1 I NO Specification M5x12 M6 M4x25 M4x4 1 2 1 1 1 1 1 1 1 Qt y 1 2 1 61 0510 61 0401 61 0309 61 0307 BP 12 5 61 0200 TP 12 5 61 1501 61 0100 Specification...

Page 11: ...ing P 16 19 O Ring P 16 Cylinder Port 27 3 11 52 O Ring P 24 60 70 Limit Switch 82 277 PT1 2 Overload Cylinder Port 74 Air Drain Bolt 13 70 33 PT1 4 Air Supply Port D C A B D C E 16 d 2005 07 08 SANDS...

Reviews: