background image

5

if they have been given supervision or instruction concerning use of the appliance 

in a safe way and understand the hazards involved. Children shall not play with the 

appliance. Cleaning and user maintenance shall not be made by children without 

supervision.

•  Children should be supervised so they do not play with the main cable.

•  The unit must have 30 cm minimum clearance around combustible surfaces.

•  If the mains cable is damaged, do not use the appliance. Ensure the appliance 

unplugged from the mains socket. Contact your qualified service agent to replace the 

mains cable.

WARNING

IT IS HAZARDOUS FOR ANYONE OTHER THAN AUTHORISED SERVICE PERSONNEL 

TO CARRY OUT SERVICING OF REPAIRS WHICH INVOLVE THE REMOVAL OF 

COVERS.

TO AVOID THE RISK OF AN ELECTRICAL SHOCK DO NOT ATTEMPT REPAIRS 

YOURSELF.

•  The appliance shall be installed in accordance with national wiring regulations.

•  For correct installation of the appliance, the minimum permissible distances to adjacent 

structures is 30 cm.

•  Type and rating of fuses:

•  PCB fuse:   T; 3.15 A; 250 VAC

•  The appliance shall be installed, operated and stored in a room with a floor area larger 

than 4 m

2

.

•  Maximum refrigerant charge amount: 0.075 kg

S20DH19E_IB_5L_Final190829V1.indb   5

30/08/2019   18:27

Summary of Contents for S20DH19E

Page 1: ...20L DEHUMIDIFIER Instruction Manual S20DH19E S20DH19E_IB_5L_Final190829V1 indb 1 30 08 2019 18 27...

Page 2: ...S20DH19E_IB_5L_Final190829V1 indb 2 30 08 2019 18 27...

Page 3: ...uitable Environments 11 Operation 11 Setting the Humidity Level 12 Setting the Auto On Off Time 12 Water Tank Full 12 Auto Defrost 12 Continuous Drainage 13 Cleaning Maintenance 14 Hints Tips 15 Speci...

Page 4: ...lydisconnectfromthepowersupply Donotblockorrestricttheairflowaroundtheappliance Positiontheunitsothattheair inletandexhaustgrillesarenotblockedorrestrictedinanyway Allow300mmofclearancearoundtheunit D...

Page 5: ...ket Contactyourqualifiedserviceagenttoreplacethe mainscable WARNING ITISHAZARDOUSFORANYONEOTHERTHANAUTHORISEDSERVICEPERSONNEL TOCARRYOUTSERVICINGOFREPAIRSWHICHINVOLVETHEREMOVALOF COVERS TOAVOIDTHERISK...

Page 6: ...6 GR F 300mm S20DH19E_IB_5L_Final190829V1 indb 6 30 08 2019 18 27...

Page 7: ...7 8 30cm 30cm PCB T 3 15A 250VAC 4m2 0 075 S20DH19E_IB_5L_Final190829V1 indb 7 30 08 2019 18 27...

Page 8: ...se refer to your individual product for details Instruction Manual Instruction Manual Drain Hose Thank youfor purchasing your new product We recommend that you spend some time reading this instruction...

Page 9: ...duct Overview Front View Rear View Drain Outlet Removable Water Tank Water Level Window Castor Mains Cable Air Filter Handle Control Panel Air Outlet Flap S20DH19E_IB_5L_Final190829V1 indb 9 30 08 201...

Page 10: ...POWER Indicator Illuminate when the unit is on 1 2 3 4 5 6 7 8 9 10 11 12 13 9 TIMER Button Press to enter timer settings 10 FAN Button Press to select the between Low Med and High fan speed in Dehumi...

Page 11: ...enefits Protects clothes and leather products from becoming mouldy Dehumidifies flooring and carpets Prevents ceiling and windows from condensation To obtain the best results avoid opening windows and...

Page 12: ...et the Auto On time between 0 5 to 24 hours 3 Press TIMER to confirm To cancel the Auto On Off settings switch off on the unit or set the TIMER to 0 0 Water Tank Full When the water tank is full the F...

Page 13: ...the water hose into the drain outlet as shown Place or connect the other end of the hose to a suitable drainage facility When the hose is not being used remove the hose from the drain outlet The hose...

Page 14: ...lean the air filter more often Remove the air filter Clean the air filter with a vacuum cleaner lf the air filter is very dirty you can wash it in warm water never use hot or soapy water Make sure tha...

Page 15: ...xcessive noise Ensure the unit is on a stable flat surface Clean the air filter No air coming out from the air outlet Clean the air filter Specifications Model S20DH19E Power Supply 220 240V 50Hz Dehu...

Page 16: ...16 GR Instruction Manual S20DH19E_IB_5L_Final190829V1 indb 16 30 08 2019 18 27...

Page 17: ...17 GR S20DH19E_IB_5L_Final190829V1 indb 17 30 08 2019 18 27...

Page 18: ...18 GR 1 2 F 3 4 5 6 7 SMD 8 1 2 3 4 5 6 7 8 9 10 11 12 13 9 10 SMD 11 12 SMD 13 S20DH19E_IB_5L_Final190829V1 indb 18 30 08 2019 18 27...

Page 19: ...19 GR 1 2 5 C 30 32 C 30 1 2 3 4 3 S20DH19E_IB_5L_Final190829V1 indb 19 30 08 2019 18 27...

Page 20: ...20 GR 35 85 1 0 0 2 0 5 24 3 1 0 0 2 0 5 24 3 0 0 S20DH19E_IB_5L_Final190829V1 indb 20 30 08 2019 18 27...

Page 21: ...21 GR S20DH19E_IB_5L_Final190829V1 indb 21 30 08 2019 18 27...

Page 22: ...22 GR 2 S20DH19E_IB_5L_Final190829V1 indb 22 30 08 2019 18 27...

Page 23: ...23 GR S20DH19E 220 240V 50Hz 20 L 30 C 80 RH 440 W 3 L R290 0 075 15 510 350 245 mm S20DH19E_IB_5L_Final190829V1 indb 23 30 08 2019 18 27...

Page 24: ...erve natural resources and ensure that it is recycled in a manner that protects human health and the environment For more information about where you can drop off your waste for recycling please conta...

Reviews: