![Sandpiper SB1-A Service And Operating Manual Download Page 8](http://html1.mh-extra.com/html/sandpiper/sb1-a/sb1-a_service-and-operating-manual_807526008.webp)
sb1dl4sm-REV0108
Models SB1-A & SB25A Page 6
This pump is pressurized
internally with air pressure
during operation. Always
make certain that all bolting
is in good condition and
that all of the correct
bolting is reinstalled during assembly.
WARNING
Before pump operation,
i n s p e c t a l l g a s k e t e d
fasteners for looseness
caused by gasket creep. Re-
torque loose fasteners to
prevent leakage. Follow recommended torques
stated in this manual.
CAUTION
When used for toxic or
aggressive fluids, the pump
should always be flushed
clean prior to disassembly.
WARNING
Before maintenance or
repair, shut off the com-
pressed air line, bleed the
pressure, and disconnect
the air line from the pump.
The discharge line may be
pressurized and must be bled of its pressure.
WARNING
Before doing any main-
tenance on the pump, be
certain all pressure is
completely vented from the
pump, suction, discharge,
piping, and all other openings and connections.
Be certain the air supply is locked out or made
non-operational, so that it cannot be started
while work is being done on the pump. Be certain
that approved eye protection and protective
clothing are worn all times in the vicinity of the
pump. Failure to follow these recommendations
may result in serious injury or death.
WARNING
WARNING
Airborne particles and
loud noise hazards.
Wear ear and eye
protection.
WARNING
In the event of diaphragm
rupture, pumped material
may enter the air end of the
pump, and be discharged
into the atmosphere. If
pumping a product which is hazardous or toxic,
the air exhaust must be piped to an appropriate
area for safe disposition.
IMPORTANT SAFETY
INFORMATION
Take action to prevent static
sparking. Fire or explosion
can result, especially when
handling flammable liquids.
The pump, piping, valves,
containers or other miscellaneous equipment
must be grounded. (See page 32)
WARNING
IMPORTANT
Read these safety warnings
and instructions in this
manual completely, before
installation and start-up
of the pump. It is the responsibility of the
purchaser to retain this manual for reference.
Failure to comply with the recommendations
stated in this manual will damage the pump,
and void factory warranty.
Read these safety warnings
and instructions in this
manual completely, before
installation and start-up
of the pump. It is the responsibility of the
purchaser to retain this manual for reference.
Failure to comply with the recommendations
stated in this manual will damage the pump,
and void factory warranty.
RECYCLING
Many components of SANDPIPER
®
AODD pumps are made
of recyclable materials (see chart on page 9 for material
specifications). We encourage pump users to recycle worn out parts
and pumps whenever possible, after any hazardous pumped fluids
are thoroughly flushed.
II 2GD T5
CE
Pump complies with EN809 Pumping Directive, Directive 98/37/
EC Safety of Machinery, and Directive 94/9/EC, EN13463-1
Equipment for use in Potentially Explosive Environments. For
reference to the directive certificates visit: www.warrenrupp.com.
The Technical File No. AX1 is stored at KEMA, Notified Body 0344,
under Document #203040000.