520.012.000 8/05
Models HDF3-A & HDF4-A Page 1 Rev B
IMPORTANT
Read these instructions completely,
before installation and start-up. It is the
responsibility of the purchaser to retain
this manual for reference. Failure to
comply with the recommendations
stated in this manual will damage the
pump, and void factory warranty.
WARNING
Take action to prevent static sparking.
Fire or explosion can result, especially
when handling flammable liquids. The
pump, piping, valves, containers or
other miscellaneous equipment must
be grounded. (See page 5)
BEFORE OPERATION
Before pump operation, inspect all
gasketed fasteners for looseness
caused by gasket creep. Retorque loose
fasteners to prevent leakage. Follow
recommended torques stated in the card
attached to the new pump.
DANGER
Before doing any maintenance on the
pump, be certain all pressure is
completely vented from the pump,
suction, discharge, piping, and all other
openings and connections. Be certain
the air supply is locked out or made
non-operational, so that it cannot be
started while work is being done on
the pump. Be certain that approved
eye protection and protective clothing
are worn all times in the vicinity of the
pump. Failure to follow these
recommendations may result in
serious injury or death.
CAUTION
In the event of diaphragm rupture,
pumped material may enter the air end
of the pump, and be discharged into the
atmosphere. If pumping a product which
is hazardous or toxic, the air exhaust
must be piped to an appropriate area for
safe disposition.
CAUTION
Before maintenance or repair, shut off
the compressed air line, bleed the
pressure, and disconnect the air line
from the pump. The discharge line may
be pressurized and must be bled of its
pressure. When used for toxic or
aggressive fluids, the pump should
always be flushed clean prior to
disassembly.
PLEASE NOTE!
The photos shown in this manual are for general instruction only. Your specific
model may not be shown. Always refer to the parts list and exploded view drawing
for your specific model when installing, disassembling or servicing your pump.
PRINCIPLE OF PUMP OPERATION
This flap swing check valve pump is powered by compressed air and is a 1:1
pressure ratio design. It alternately pressurizes the inner side of one diaphragm
chamber, while simultaneously exhausting the other inner chamber. This causes
the diaphragms, which are connected by a common rod, to move endwise. Air
pressure is applied over the entire surface of the diaphragm, while liquid is
discharged from the opposite side. The diaphragm operates under a balanced
condition during the discharge stroke, which allows the unit to be operated at
discharge heads over 200 feet (61 meters) of water head.
Since the diaphragms are connected by a common rod, secured by plates to the
center of the diaphragms, one diaphragm performs the discharge stroke, while the
other is pulled to perform the suction stroke in the opposite chamber.
For maximum diaphragm life, keep the pump as close to the liquid being pumped
as possible. Positive suction head in excess of 10 feet of liquid (3.048 meters) may
require a back pressure regulating device. This will maximize diaphragm life.
Alternate pressuring and exhausting of the diaphragm chamber is performed by
means of an externally mounted, pilot operated, four-way spool type air distribution
valve. When the spool shifts to one end of the valve body, inlet air pressure is
applied to one diaphragm chamber and the other diaphragm chamber exhausts.
When the spool shifts to the opposite end of the valve body, the porting of chambers
is reversed. The air distribution valve spool is moved by an internal pilot valve which
alternately pressurizes one side of the air distribution valve spool, while exhausting
the other side. The pilot valve is shifted at each end of the diaphragm stroke by the
diaphragm plate coming in contact with the end of the pilot valve spool. This pushes
it into position for shifting of the air distribution valve.
The chambers are manifolded together with a suction and discharge check valve
for each chamber, maintaining flow in one direction through the pump.
INSTALLATION & START-UP
Locate the pump as close to the product being pumped as possible, keeping
suction line length and number of fittings to a minimum. Do not reduce line size.
For installations of rigid piping, short flexible sections of hose should be installed
between pump and piping. This reduces vibration and strain to the piping system. A
Warren Rupp Tranquilizer
®
Surge Suppressor is recommended to further reduce
pulsation in flow.
This pump was tested at the factory prior to shipment and is ready for operation.
It is completely self-priming from a dry start for suction lifts of 20 feet (6.096 meters)
or less. For suction lifts exceeding 20 feet of liquid, fill the chambers with liquid prior
to priming.
AIR SUPPLY
Air supply pressures cannot exceed 125 psi (8.61 bar). Connect the pump air
inlet to an air supply of sufficient capacity and pressure required for desired
performance. When the air line is solid piping, use a short length of flexible hose
(not less than 3/4" (19mm) in diameter) between pump and piping to eliminate
strain to pipes.
AIR INLET & PRIMING
For start-up, open an air valve approximately 1/2" to 3/4" turn. After the unit
primes, an air valve can be opened to increase flow as desired. If opening the valve
WARREN RUPP, INC. A Unit of IDEX Corporation • P.O. Box 1568 • Mansfield, Ohio 44901-1568 USA • (419) 524-8388 • Fax (419) 522-7867
SERVICE AND OPERATING MANUAL
Models HDF3-
Models HDF3-
Models HDF3-
Models HDF3-
Models HDF3-A
A
A
A
A
T
TT
TType 7
ype 7
ype 7
ype 7
ype 7
HDF4-
HDF4-
HDF4-
HDF4-
HDF4-A
A
A
A
A
TTTTType 3
ype 3
ype 3
ype 3
ype 3
II 2GD b T5
CE