Sandpiper F15C Service & Operating Manual Download Page 14

f15mdl1sm-rev0219

sandpiperpump

.

com

14

 • Model F15C Metallic 

Composite Repair Parts List

Air Valve Assembly

Item #

Qty.

Description

Part Number

1

-

Valve Body Assembly (includes items 2-8)

P31-200-NP

2

1

Valve Body

P31-201NP

3

2

End Cap

P50-300NP

4

2

End Cap Gasket

P50-110

5

1

Valve Body Gasket

P31-202

6

1

Valve Spool

P50-104

7

3

Glyde Ring Assembly

P50-104C

8

12

Mounting Screws (8 included on item 1)

S1001

Center Section Assembly

Item #

Qty.

Description

Part Number

9

1

Center Block Assembly (includes items 14 & 15)

P31-400NP ASY

10

2

Air Chamber

P31-1013ANP

11

2

Air Chamber Gasket

P31-109

12

4

Air Chamber Bolt

SP31-404

13

2

Air Chamber Bolt (Long)

P31-404B

14

4

Bearing Sleeve

P31-403

15

2

Main Shaft O-Ring

P24-403

16

1

Pilot Shaft

P50-112

17

5

Pilot Spacer

P24-106P

18

6

Pilot O-Ring

P24-107

19

2

Pilot Ring

P50-119

20

2

Pilot Retainer

P50-109

21

2

Screw

S1001

22

2

Stop Nut

P24-108

23

1

Muffler

530 .036 .000

Diaphragm Assembly / Elastomers

Item #

Qty.

Description

Part Number

FDA Santoprene

FDA Hytrel

Two Piece

Fusion

24

1

Main Shaft

P31-103

P31-103

P31-102

P31-103

25

2

Main Shaft Stud

V221F

V221F

V221F

N/A

26

2

Diaphragm

V163TPEXLFG

V163TPEFG

V163TF

V163F

44

2

Back-Up Diaphragm

V163TFB

27

2

Inner Diaphragm Plate

V161CNP

V161CNP

V161CNP

N/A

28

2

Outer Diaphragm Plate

 SVB161-3A

SVB1613-A

SV161TOFG

N/A

29

4

Valve Ball 

V171TPEXLFG

V171TPEFG

V171TF

V171TF

30

4

Manifold Tee Seal

V273E

V273TF

31

4

Manifold Elbow Seal

V274E

V274TF

Wet End Assembly

Item #

Qty.

Description

Part Number

32

2

Water Chamber

P29-165

33

4

Manifold Elbow

P29-167

34

4

Ball Cage

670 .V004 .110

35

2

Manifold Tee

P29-168

36

1

Stand Attachment

SP31-651

37

1

Pump Stand

P29-650CP

38

1

Locking Pin

P29-652

39

4

Large Clamp

SP31-110A

40

4

Large Clamp Bolt

SP31-110B

41

4

Large Clamp Wing Nut

FG39C

42

4

Small Tri-Clamp

V273A

43

4

Large Tri-Clamp

V274A

3: EXP

 VIEW

Summary of Contents for F15C

Page 1: ...nit of IDEX Corporation 800 N Main St Mansfield Ohio 44902 USA Telephone 419 524 8388 Fax 419 522 7867 SANDPIPERPUMP COM Copyright 2017 Warren Rupp Inc All rights reserved Certified Quality ISO 9001 C...

Page 2: ...n appropriate area for safe containment This pump is pressurized internally with air pressure during operation Make certain that all fasteners and piping connections are in good condition and are rein...

Page 3: ...C to 108 C T4 T135 C 20 C to 160 C T3 T200 C 20 C to 177 C 225 C T2 Table 1 Category 2 ATEX Rated Pumps Ambient Temperature Range C Process Temperature Range C 20 C to 60 C 20 C to 150 C Table 2 Categ...

Page 4: ...OPERATION 9 Principle of Pump Operation Recommended Installation Guide Troubleshooting Guide SECTION 3 EXPLODED VIEW 12 Composite Repair Parts Drawing Service Repair Kits Composite Repair Parts List...

Page 5: ...nless Steel Diaphragm Check Valve Materials D FDA Santoprene FDA Santoprene H FDA Hytrel PTFE K PTFE with FDA Hytrel Backer PTFE Z PTFE One Piece Fusion Diaphragm PTFE Your Serial fill in from pump na...

Page 6: ...ters Feet 0 0 40 80 120 160 200 240 280 320 10 20 30 40 50 60 80 90 70 0 1 2 3 4 5 6 7 8 9 10 BAR 50 100 150 200 1 1 2 Sanitary Pump ELASTOMERIC AND TPE FITTED Flow Rate Adjustable to 0 86 gpm 325 5 l...

Page 7: ...n EPDM Shows very good water and chemical resistance Has poor resistance to oils and solvents but is fair in ketones and alcohols 280 F 138 C 40 F 40 C Hytrel Good on acids bases amines and glycols at...

Page 8: ...brackets The dimensions on this drawing are for reference only A certified drawing can be requested if physical dimensions are needed 9 78 25 72 1 1 2 SUCTION SANITARY CLAMP FLANGE 29 82 31 56 1 1 2...

Page 9: ...e check valve and into the outer fluid chamber Suction side stroking also initiates the reciprocating shifting stroking or cycling action of the pump The suction diaphragm s movement is mechanically p...

Page 10: ...operating Water in the air supply can be reduced by using a point of use air dryer Air Inlet And Priming To start the pump slightly open the air shut off valve After the pump primes the air valve can...

Page 11: ...oint of use air drier Clogged manifolds Clean manifolds to allow proper air flow Deadhead system pressure meets or exceeds air supply pressure Increase the inlet air pressure to the pump Pump is desig...

Page 12: ...t the suction line from the pump Connect the steam line to the pump inlet Maintain the flow of steam through the pump for at least five minutes after the temperature at the outlet has reached 200 F 94...

Page 13: ...32 25 28 31 31 15 E PILOT Y DETAIL FUSION DIAPHRAGM ASY Torque Setting 350 in lbs 39 N m Torque Setting 200 in lbs 22 N m 17 18 19 22 16 19 22 PILOT ASY DETAIL 24 26 39 41 40 34 29 43 33 30 30 33 43 3...

Page 14: ...0 2 Pilot Retainer P50 109 21 2 Screw S1001 22 2 Stop Nut P24 108 23 1 Muffler 530 036 000 Diaphragm Assembly Elastomers Item Qty Description Part Number FDA Santoprene FDA Hytrel Two Piece Fusion 24...

Page 15: ...N809 2012 Pumps and Pump Units for Liquids Common Safety Requirements to verify conformance 5 YEAR Limited Product Warranty Warren Rupp Inc Warren Rupp warrants to the original end use purchaser that...

Page 16: ...0B1SKSNTF600 F30B1SZSNTF600 Food Processing Pump Models Tranquilizer Surge Suppressors T15B1SSTSTS600 T20B1SASWTS600 T20B1SDSWTS600 T20B1SASSTS600 T20B1SDSSTS600 T20B1SASWTS600 T20B1SDSWTS600 T20B1SAS...

Page 17: ...Series F Series T Series EH Series SH Series GH Series Conductive plastic pump models with integral muffler S Series PB Series Tranquilizer surge suppressors Hazardous Location Applied I M1 Ex h I Ma...

Reviews: