S&P SILENT-300 DESIGN Instruction Leaflet Download Page 7

the fan with timer utilising the same switch as 
for the lighting circuit. 
 
To set the timer, turn the potentiometer on the 
printed circuit board as (fig. 7). 
- To reduce the "run on" time, turn 
anticlockwise (min. 1minutes) 
- To increase the "run on" time , turn 
clockwise (max: 30 minutes). 
 

SILENT-300 CHZ 

Models provided with an electronic 
humidistat which can be adjusted from 60% 
to 90 % RH (relative humidity) and with a 
timer, adjustable between 2 and 20 minutes. 
 
Operation 

Case 1

:Automatic operation (fig.9) 

In automatic operation, the humidistat 
causes the extractor to operate automatically 
when the humidity level in the room is higher 
than the set level. The extractor will stop 
automatically when the humidity drops below 
the selected level and after the selected 
period set on the timer. 

Case 2

: Automatic operation as in case 1 

with the facility to override the hygrostat by 
means of the light switch (fig.8), when the 
humidity level in the room is lower than the 
selected level. In this case, the extractor 
continues to operate for the selected period 
set on the timer after the switch light has 
been switched off. 
 

ATENTION: When the himidity rate is 
above the selected value, the automatic 
option takes precedence over themanual 
and the unit cannot then be switched off 
using a switch. 

 
The desired humidity level is selected by 
means of a potentiometer 

“% Hr

 ” positioned 

on the printed circuit board (fig.10) and 
accessible once the grille (1) has been 
removed. 
- To increase the humidity setting turn 
anticlockwise (min.60 %) 
- To reduce the humidity setting turn 
clockwise (max. 90 %) 
To set the timer, turn the potentiometer “ 

t min

” on the printed circuit board (fig.10): 

- To reduce the "run on" time, turn 
anticlockwise (min. 2minutes) 
- To increase the "run on" time , turn 
clockwise (max: 20 minutes). 
 

Maintenance 

 
The extractor fan only requires periodical 
cleaning using a cloth lightly impregnated 
with a soft detergent. 
 

After Sales Service 

We recommend you not to try to dismantle or 
remove any other parts than those 
mentioned as any tampering would 
automatically cancel the S&P guarantee. If 
you detect any fault, contact your S&P 
dealer. 
 
S&P reserves the right to alter specifications 
without 
notice 

Summary of Contents for SILENT-300 DESIGN

Page 1: ...struction leaflet Notice de montage Montageanweisungen Montage en gebruiksaanwijzing Instrucções para a montagem Istruzioni per l installazione Användar instruktion Brugervejledning Instrukcja obslugi Návod Käyttöohjeet Инструкции по сборке ...

Page 2: ...Fig 1 1 4 2 3 ...

Page 3: ...Fig 4 Fig 3 Fig 2 L L N N Ls L L N N Ls ...

Page 4: ...Fig 7 Fig 6 Fig 5 L L N N Ls L L N N Ls T min SILENT 300 CRZ ...

Page 5: ...Fig 10 Fig 9 Fig 8 T min HR L L N N Ls L L N N Ls ...

Page 6: ... to the airflow and that the impeller turns freely Fix the extractor to the wall in such a way that it is not distorted in order to avoid noise generation or problems with the rotation of the impeller Make sure that the backdraught shutter opens freely and has not being damaged in transit Precautions must be taken to avoid the back flow of gases into the room from the open flue of gas or other fue...

Page 7: ...the extractor continues to operate for the selected period set on the timer after the switch light has been switched off ATENTION When the himidity rate is above the selected value the automatic option takes precedence over themanual and the unit cannot then be switched off using a switch The desired humidity level is selected by means of a potentiometer Hr positioned on the printed circuit board ...

Page 8: ...Soler Palau Polígono Industrial Llevant c Llevant 4 08150 Parets del Vallès Barcelona Spain Tel 34 93 571 93 00 Fax 34 93 571 93 11 http www solerpalau com Ref 0288259013 ...