S&P SILENT-200 DESIGN Instruction Leaflet Download Page 7

Model provided with a 4 positions adjustable
electronic timer:Fig.5 shows how to connect
the fan with timer utilising the same switch as
for the lighting circuit.

To set the timer, turn the potentiometer on the
printed circuit board as (fig. 7).
- To reduce the "run on" time, turn
anticlockwise (min. 1 minutes)
- To increase the "run on" time , turn

clockwise (max: 30 minutes).

Models provided with an electronic
humidistat which can be adjusted from 60%
to 90 % RH (relative humidity) and with a
timer, adjustable between 2 and 20 minutes.

1: Automatic operation (fig.9)

In automatic operation, the humidistat causes
the extractor to operate automatically when the
humidity level in the room is higher than the set
level. The extractor will stop automatically when
the humidity drops below the selected level and
after the selected period set on the timer.

2: Automatic operation as in case 1 with

the facility to override the hygrostat by means
of the light switch (fig.8), when the humidity
level in the room is lower than the selected
level. In this case, the extractor continues to
operate for the selected period set on the timer
after the switch light has been switched off.

The desired humidity level is selected by
means of a potentiometer “

” positioned

on the printed circuit board (fig.10) and
accessible once the grille (1) has been
removed.
- To increase the humidity setting turn

anticlockwise (min.60 %)

- To reduce the humidity setting turn

clockwise (max. 90 %)

To set the timer, turn the potentiometer “

” on the printed circuit board (fig.10):

- To reduce the "run on" time,

turn

anticlockwise (min. 2 minutes)

- To increase the "run on" time , turn

clockwise (max: 20 minutes).

The extractor fan only requires periodical
cleaning using a cloth lightly impregnated
with a soft detergent.

We recommend you not to try to dismantle or
remove any other parts than those
mentioned as any tampering would
automatically cancel the S&P guarantee. If
you detect any fault, contact your S&P
dealer.

SILENT-200 CHZ

Operation

Maintenance

After Sales Service

Case

Case

ATENTION: When the humidity rate is
above the selected value, the automatic
option takes precedence over the manual
and the unit cannot then be switched off
using a switch.

% Hr

t

min.

S&P reserves the right to alter specifications without
notice

Summary of Contents for SILENT-200 DESIGN

Page 1: ...struction leaflet Notice de montage Montageanweisungen Montage en gebruiksaanwijzing Instrucções para a montagem Istruzioni per l installazione Användar instruktion Brugervejledning Instrukcja obslugi Návod Käyttöohjeet Инструкции по сборке ...

Page 2: ...Fig 1 1 4 2 3 ...

Page 3: ...Fig 4 Fig 3 Fig 2 L L N N Ls L L N N Ls ...

Page 4: ...Fig 7 Fig 6 Fig 5 L L N N Ls L L N N Ls T min SILENT 200 CRZ ...

Page 5: ...Fig 10 Fig 9 Fig 8 T min HR L L N N Ls L L N N Ls ...

Page 6: ...h the rotation of the impeller Make sure that the backdraught shutter opens freely and has not being damaged in transit Introduce the mains cable through the cable entry 4 and fix it to the wall Connect the electrical wiring as set out below and then mount the protection grille 1 The SILENT 200 is an extractor designed for a single phase supply with voltage and frequency as indicated on the rating...

Page 7: ...this case the extractor continues to operate for the selected period set on the timer aftertheswitchlighthasbeenswitchedoff The desired humidity level is selected by means of a potentiometer positioned on the printed circuit board fig 10 and accessible once the grille 1 has been removed To increase the humidity setting turn anticlockwise min 60 To reduce the humidity setting turn clockwise max 90 ...

Page 8: ...Soler Palau Polígono Industrial Llevant c Llevant 4 08150 Parets del Vallès Barcelona Spain Tel 34 93 571 93 00 Fax 34 93 571 93 11 http www solerpalau com Ref 0288274004 ...

Reviews: