On  receipt  of  the  product  we 

recommend  that  you  to  check  the 

following: 

1- That it is the correct model. 

2- That the details on the rating label 

are  those  you  require:  voltage, 

frequency, amps... 

The installation must be carried out in 

accordance  with  the  electrical 

standards in force in your country. 

 

This appliance is not intended for use 

by  young  children  or  infirm  persons 

unless  they  have  been  adequately 

supervised by a responsible person to 

ensure  that  they  can  use  the 

appliance  safely.  Young  c hildren 

should  be  supervised  to  ensure  that 

they do not play with the appliance 

 

Installation

 

IMPORTANT

:  Before  installing  and 

wiring  the  unit,  ensure  that  the  main 

supply is disconnected. 

 

RMT Series  

Description 

The  RMT  series  consists  of  5  three-

phase 

auto-transformer 

speed 

controllers, 400V-50/60Hz. 

The  manual  switch  C  (fig.1)  permits 

five speed positions and “OFF”. 

 

Wiring 

Put  the  switch  C  to  position  0.  For 

Access to the connection block, open 

the  front  cover  “T”.  Carry  out  the 

wiring as indicated in fig.3. 

 

Should  the  fan  rotate  in  the  wrong 

direction,  reverse  the  connection  of 

any two wires on the terminals going 

to the motor.  

 

 

Maximum permissible currents: 

Type controller 

Max. current (A) 

RMT-1,5 

1,5 

RMT-2,5 

2,5 

RMT-5 

RMT-8 

RMT-12 

12 

 

 

RMB Series 

Description 

The RMB series consists of 4 single-

phase 

auto-transformer 

speed 

controllers, 230V-50/60Hz. 

The  manual  switch  C  (fig.1)  permits 

five speed positions and “OFF”. 

 

Wiring 

Put  the  switch  C  to  position  0.  For 

Access to the connection block, open 

the  front  cover  “T”.  Carry  out  the 

wiring as indicated in fig.4. 

 

Maximum permissible currents: 

Type controller 

Max. current (A) 

RMB-1,5 

1,5 

RMB-3,5 

3,5 

RMB-8 

RMB-10 

10 

 

 

After Sales Service

  

We  recommend  you  not  to  try  to 

dismantle  or  remove  any  other  parts 

than  those  mentioned  as  any 

tampering would automatically cancel 

the S&P guarantee. If you detect any 

fault, contact your S&P dealer. 

 

 

 

 

 

 

S&P reserves the right to alter specifications without notice 

 

ESPAÑOL 

Recomendamos  verificar  los  siguientes 

puntos a la recepción de este aparato: 

1- Que el modelo es el correcto 

2- Que los detalles que figuran en la placa 

de  características  sean  los  que  usted 

precisa: voltaje, intensidad... 

La  instalación  debe  hacer  acorde  con  los 

reglamentos vigentes en cada país. 

Este aparato no está destinado al uso por 

niños  o  personas  enfermas  salvo  que 

estén  adecuadamente  supervisadas  por 

una  persona  responsable  para  asegurar 

que  utilizan  el  aparato  de  forma  segura. 

Los  niños  pequeños  deben  ser 

supervisados para asegurar que no juegan 

con el aparato 

 

Instalación 

IMPORTANTE: 

Antes  de  proceder  a  la 

instalación  i  conexión  del  aparato, 

asegurarse de desconectar el suministro 

eléctrico. 

 

Serie RMT  

La  serie  RMT  está  compuesta  por  5 

reguladores electromagnéticos trifásicos 

por autotransformador, 400V-50/60Hz. 

Por 

accionamiento 

manual 

del 

conmutador C (fig.1) se pueden obtener 

5 velocidades de giro escalonadas. 

 

Conexión eléctrica 

Colocar 

el 

conmutador 

de 

accionamiento  C  en  la posición 0.  Para 

tener  acceso  a  la  regleta  de  conexión, 

abrir  la  tapa  delantera  T.  Efectuar  la 

conexión según se indica en la fig.3. 

Caso de que una vez puesto en marcha 

el ventilador gire en sentido contrario al 

deseado,  invertirla  conexión  de  dos 

cables  en  los  bornes  de salida  hacia el 

motor.  

 

 

 

 

Intensidades máximas admisibles 

Regulador tipo 

Intensidad máx. (A) 

RMT-1,5 

1,5 

RMT-2,5 

2,5 

RMT-5 

RMT-8 

RMT-12 

12 

 

Serie RMB 

La  serie  RMT  está  compuesta  por  4 

reguladores 

electromagnéticos 

monofásicos  por  autotransformador 

230V-50/60Hz. 

Por 

accionamiento 

manual 

del 

conmutador C (fig.1) se pueden obtener 

5 velocidades de giro escalonadas. 

 

Conexión eléctrica 

Colocar 

el 

conmutador 

de 

accionamiento  C  en  la posición 0.  Para 

tener  acceso  a  la  regleta  de  conexión, 

abrir  la  tapa  delantera  T.  Efectuar  la 

conexión según se indica en la fig.4. 

 

Intensidades máximas admisibles 

Regulador tipo 

Intensidad máx. (A) 

RMB-1,5 

1,5 

RMB-3,5 

3,5 

RMB-8 

RMB-10 

10 

 

Asistencia técnica

 

La extensa red de Servicios Oficiales S&P 

garantiza una adecuada asistencia técnica 

en cualquier punto de España. En caso de 

observar  alguna  anomalía  en  el 

funcionamiento  del  aparato  rogamos 

presentarlo para su revisión en cualquiera 

de los Servicios mencionados donde será 

debidamente  atendido. 

Cualquier  manipulación  efectuada  en  el 

aparato  por  personas  ajenas  a  los 

Servicios Oficiales de S&P nos obligaría a 

cancelar su garantía. 

 

S&P se reserva el derecho de modificaciones sin previo aviso. 

- Working temperature: 0-40ºC.
- Minimum working voltage: 90 Vac.

ENGLISH 

On  receipt  of  the  product  we 

recommend  that  you  to  check  the 

following: 

1- That it is the correct model. 

2- That the details on the rating label 

are  those  you  require:  voltage, 

frequency, amps... 

The installation must be carried out in 

accordance  with  the  electrical 

standards in force in your country. 

 

This appliance is not intended for use 

by  young  children  or  infirm  persons 

unless  they  have  been  adequately 

supervised by a responsible person to 

ensure  that  they  can  use  the 

appliance  safely.  Young  c hildren 

should  be  supervised  to  ensure  that 

they do not play with the appliance 

 

Installation

 

IMPORTANT

:  Before  installing  and 

wiring  the  unit,  ensure  that  the  main 

supply is disconnected. 

 

RMT Series  

Description 

The  RMT  series  consists  of  5  three-

phase 

auto-transformer 

speed 

controllers, 400V-50/60Hz. 

The  manual  switch  C  (fig.1)  permits 

five speed positions and “OFF”. 

 

Wiring 

Put  the  switch  C  to  position  0.  For 

Access to the connection block, open 

the  front  cover  “T”.  Carry  out  the 

wiring as indicated in fig.3. 

 

Should  the  fan  rotate  in  the  wrong 

direction,  reverse  the  connection  of 

any two wires on the terminals going 

to the motor.  

 

 

Maximum permissible currents: 

Type controller 

Max. current (A) 

RMT-1,5 

1,5 

RMT-2,5 

2,5 

RMT-5 

RMT-8 

RMT-12 

12 

 

 

RMB Series 

Description 

The RMB series consists of 4 single-

phase 

auto-transformer 

speed 

controllers, 230V-50/60Hz. 

The  manual  switch  C  (fig.1)  permits 

five speed positions and “OFF”. 

 

Wiring 

Put  the  switch  C  to  position  0.  For 

Access to the connection block, open 

the  front  cover  “T”.  Carry  out  the 

wiring as indicated in fig.4. 

 

Maximum permissible currents: 

Type controller 

Max. current (A) 

RMB-1,5 

1,5 

RMB-3,5 

3,5 

RMB-8 

RMB-10 

10 

 

 

After Sales Service

  

We  recommend  you  not  to  try  to 

dismantle  or  remove  any  other  parts 

than  those  mentioned  as  any 

tampering would automatically cancel 

the S&P guarantee. If you detect any 

fault, contact your S&P dealer. 

 

 

 

 

 

 

S&P reserves the right to alter specifications without notice 

 

Summary of Contents for RMB Series

Page 1: ...RMB RMT...

Page 2: ......

Page 3: ......

Page 4: ...arant a S P se reserva el derecho de modificaciones sin previo aviso Temperatura de trabajo 0 40 C Voltaje m nimo de trabajo 90Vac ESPA OL Recomendamos verificar los siguientes puntos a la recepci n d...

Page 5: ...P dealer S P reserves the right to alter specifications without notice Working temperature 0 40 C Minimum working voltage 90 Vac ENGLISH On receipt of the product we recommend that you to check the fo...

Page 6: ...e indiqu fig 3 Intensit s maximales admissibles Type variateur Intensit max A RMB 1 5 1 5 RMB 3 5 3 5 RMB 8 8 RMB 10 10 Entretien Cet appareil ne n cessite aucun entretien particulier Nous vous consei...

Page 7: ...ung oder an den jeweiligen nationalen Importeur von Produkten von Soler Palau Einsatztemperatur 0 40 C Min Spannung 90 Vac DEUTSCH Bitte pr fen Sie das Ger t nach Erhalt auf einwandfreien Zustand und...

Page 8: ...garant a S P reserva se ao direito de modifica es sem aviso pr vio Temperatura de trabalho 0 40 C Voltagem m nima de trabalho 90 Vac Portugu s Recomendamos verificar os seguintes pontos na recep o de...

Page 9: ...ia S P si riserva il diritto ad effettuare modifiche senza preavviso Temperatura di lavoro 0 40 C Tensione minima di lavoro 90 Vac ITALIANO Al ricevimento dell apparato si raccomanda di verificare i s...

Page 10: ...RMT RMT Fig 1 3 400 50 RMT 1 5 1 5 RMT 2 5 2 5 RMT 5 5 RMT 8 8 RMT 12 12 0 Fig 3 0 40 C 90 RMT RMT Fig 1 3 400 50 RMT 1 5 1 5 RMT 2 5 2 5 RMT 5 5 RMT 8 8 RMT 12 12 0 Fig 3...

Page 11: ...RMB RMB Fig 2 1 230 50 RMB 1 5 1 5 RMB 3 5 3 5 RMB 8 8 RMB 10 10 0 Fig 4 Soler Palau Soler Palau...

Page 12: ...Ref 9023018400 M 01...

Reviews: