21
21
ENGLISH
6.2. PUSH CONTROL UNIT
6.2.1. User interface
1 Fan speed
display
Shows the manually
selected fan speed, or
the speed automatically
selected by the humidity
sensor.
2 Arrow Up/ON
Increases the fan speed
and/or turns the system on.
3 Automatic mode Activates/deactivates
automatic mode.
4 Arrow down/
OFF
Decreases the fan speed
and/or turns the system off.
5 Eco-Mode
Activates heat recovery
mode.
6 Full-blast mode
Activates full-blast mode.
7 Sleep mode
Activates sleep mode.
8 Filter change
display
Tells the user to change
the
fi
lter.
6.2.2. Operating modes and functions
Eco-Mode
Operating in pairs, the units change air
fl
ow
direction every 50-70 seconds dependent on
the selected fan speed, ensuring heat reco-
very.
Full-blast mode
The system runs in just one direction,
allowing a room to be thoroughly ventilated.
Heat recovery is not available in this mode.
Automatic mode
When running in automatic mode, the inte-
grated humidity sensor automatically deter-
mines fan speed.
Sleep mode
The system stops working for one hour, gi-
ving a room‘s occupants suf
fi
cient time to
get to sleep. Once the selected duration is
over, the system will continue in the pre-
viously activated mode.
Filter change display
An integrated meter is used to determine
when a
fi
lter change is needed. This is cal-
culated on the basis of the air
fl
ow volumes.
When the
fi
lter needs changing, the
fi
lter
change LED starts blinking. Once it has been
changed, just press the button to reset the
meter.
The optimal time for changing a
fi
l-
ter is dependent on local conditions
and can thus vary.
7. CLEANING AND MAINTENANCE
To ensure the ef
fi
cient functioning of your PULSE
160, all components must be regularly checked
and maintained.
7.1. MAINTENANCE INTERVAL
Component
Interval
What is to be done
Inside grille
Once every
three
months
• Wipe the surface
with a damp cloth.
Dust
fi
lter
Once every
three
months
• Use a vacuum
cleaner to free the
fi
lter of dust.
• Then wash it warm
water.
• Replace any clogged
up/defective
fi
lter.
Fan unit
Once a
year
• Clean the fan unit
using a brush
fi
rst,
then a vacuum
cleaner.
Heat
exchanger
unit
Once a
year
• Use a vacuum
cleaner to clean the
heat exchanger.
• Hold it under the
tap and wash it with
warm water.
Controls
Once a
month
• Wipe the surface
with a micro
fi
ber
cloth.
Summary of Contents for PULSE Series
Page 1: ...PULSE 160 ES EN DA CZ...