WARRANTY

INSTALL GRILLE

SERVICE PARTS

A

Install ceiling material to complete the ceiling construction and cut around the fan housing.

To attach the grille assembly to the fan housing, pinch the grille springs on the sides of the grille

assembly and position the grille into the housing with the grille springs in the appropriate slots. Push

the grille assembly towards the ceiling to secure.

1

2

4

5

6

c

a

b

8

7

9

11

12

10

d

d

Grille Assembly (includes part 2)

* Blower Assembly includes part 3, 4, 5, 6, 7, a, b

Replacement installation: Remove the screw (part a), then take out the blower assembly 

from the housing (part 8). Replace the broken parts.

* Replacement parts are shown for illustration purposes only and are not sold seperately

WARNING:

 Ensure that the fan is switched off from the supply power before replacing.

PART

PART NAME

Qty.

1
2
3
4
5
6
7
8
9

10

Housing

Blower Wheel

Blower

Power box

Wire Panel / Harness Assembly

Motor

1
2

1

1

1
1
1
1
1

Wiring Plate

4

11
12

Damper/Duct Connector

1
1

Motor Plate

Grille Spring

Hanger Bars

a

3

Screw

b

3

Screw

c

5

Screw

d

2

Screw

S&P USA Ventilation Systems,LLC.

6393 Powers Avenue Jacksonville, FL 32217 

P. 904-731-4711

F. 800-961-7379

www.solerpalau-usa.com

S&P Canada Ventilation Products, Inc.

6710 Maritz Drive Unit #7 Mississauga, ON L5W 0A1 - Canada

T. 416-744-1217     

F. 416-744-0887

www.solerpalaucanada.com

3

c

S&P USA Ventilation Systems, LLC. & S&P Canada Ventilation Products, Inc. warrants to the original end user of its products that our 

exhaust fans will be free from defects in materials and workmanship for a period of 

Six

 (

6

)

 years from the date of original purchase. 

THERE ARE NO OTHER WARRANTIES, EXPRESSED OR IMPLIED, INCLUDING BUT NOT LIMITED TO IMPLIED WARRANTIES 

OF SUITABILITY FOR A PARTICULAR PURPOSE. During this five year period, S&P will, at its option, repair returned products or 

parts, or provide replacement products or parts, without charge, for any product or part which is found to be defective under normal use.

This warranty does not cover normal maintenance and service or any parts that have been subject to misuse, negligence, accident, 

improper maintenance or repair, faulty installation or installation contrary to recommended installation instructions. S&P’s obligation to 

repair or replace, at S&P’s option, shall be the purchaser’s sole and exclusive remedy under this warranty. No labor or materials are 

covered by this warranty. S&P shall not be liable for incidental damages arising out of or in connection with product use or performance.

This warranty gives you specific legal rights. You may also have other rights which vary from state to state.

To qualify for warranty service, you must notify S&P at the address or telephone number stated below, provide the model number and 

part identification, and describe the nature of any defect in product or part. You may be required to ship a defective part to S&P. There 

will be no charge for shipping repaired or replacement parts from S&P to you if your address is in the United States or Canada. At the 

time of requesting warranty service, you must present evidence of the original purchase date.

Summary of Contents for PCD80XHP

Page 1: ...age and noisy and or unbalanced impellers keep drywall spray construction dust etc off power unit 4 Please read specification label on product for further information and requirements MODEL PCD80XHP See Connect Wiring Diagram for details Time delay knob Humidity sensor knob T H OFF 30 45 60 80 60min 20min 40min OFF 5min The control box located inside the fan housing has two settings 1 The time del...

Page 2: ...ected outwards from the cooking equipment element closest to the fan See instruction sheet for clarification 2 Two ways to connect ductwork to a factory shipped unit SENSITIVITY ADJUSTMENT The H limit has been factory set for most shower applications However if the fan is in a tub area or is being used for moisture control the H may need to be increased toward 80 If the fan is responding too often...

Page 3: ...UNIT BLACK BLK SWITCH BOX POWER SUPPLY 120V AC GROUND GRD WHITE WHT FAN RECEPTACLE WIRE PANEL SWITCH BROWN BRN FAN BRN BLK BLK LINE IN WHT WHT GRD UNIT SWITCH BOX GRD SWITCH 3 Enlarge ceiling opening to 9 1 2 by 9 1 2 leave ductwork and wiring in place 4 Connect wiring according to the wiring diagram Re install wire panel 5 Fan Mounting Mount with additional mounting holes The interior of the fan ...

Page 4: ... of its products that our exhaust fans will be free from defects in materials and workmanship for a period of Six 6 years from the date of original purchase THERE ARE NO OTHER WARRANTIES EXPRESSED OR IMPLIED INCLUDING BUT NOT LIMITED TO IMPLIED WARRANTIES OF SUITABILITY FOR A PARTICULAR PURPOSE During this five year period S P will at its option repair returned products or parts or provide replace...

Reviews: