4. INSTALL ROUND DUCTWORK
Connect the round ductwork (not included) to the damper/duct connector,
and run the ductwork to a roof or wall cap (not included). Using tape (not
included), secure all the ductwork connections so that they are air tight.
Run 120 V AC house wiring to the location of the fan. Use only UL-approved connectors (not included) to attach the house wiring to the
wiring plate. Refer to the wiring diagram, and connect the wires as shown.
ASSEMBLY INSTRUCTIONS
CONNECT ELECTRICAL WIRING
INSTALL GRILLE
3
UNIT
BLACK (BLK)
SWITCH BOX
FAN
POWER SUPPLY
120V AC
GROUND (GRD)
WHITE (WHT)
WIRING
PLATE
FAN
RECEPTACLE
FAN
Install ceiling material to complete the ceiling construction. Then, cut around
the fan housing.
To attach the grille assembly to the fan housing, pinch the grille springs on
the sides of the grille assembly, and position the grille into the housing with
the grille springs in the appropriate slots. Push the grille assembly towards
the ceiling to secure.
Fig.3
(Fig.3)
The ducting from this fan to the outside of building has a strong effect on the air
flow, noise and energy use of the fan. Use the shortest, straightest duct routing
possible for best performance, and avoid installing the fan with smaller ducts
than recommended. Insulation around the ducts can reduce energy loss and
inhibit mold growth. Fans installed with existing ducts may not achieve their