Airflow / Air Velocity Reference Table

Airflow 

(CFM)

Duct Size (in)

4

5

6

8

Air Velocity (FPM)

30

344

220

153

86

40

458

293

204

115

50

573

367

255

143

60

688

440

306

172

70

802

513

357

201

80

917

587

407

229

90

1031

660

458

258

100

1146

733

509

286

110

1261

807

560

315

120

1375

880

611

344

130

1490

953

662

372

140

1604

1027

713

401

150

1719

1100

764

430

160

1833

1173

815

458

170

1948

1247

866

487

180

2063

1320

917

516

190

2177

1393

968

544

200

2292

1467

1019

573

Note, if the Actual Measured CFM is not enough, the installer may need to increase the duct size or add a booster fan if necessary. Ensure there is no blockage 
in the ductwork first.

 

MAINTENANCE

CAUTION: BEFORE CARRYING OUT ANY MAINTENANCE OR SERVICING, ENSURE THE UNIT IS 
DISCONNECTED FROM THE MAIN ELECTRICAL SUPPLY.

S&P recommends inspection of the Motorized Damper and ES24V at least once every twelve (12) months. To inspect 
the unit disconnect from electrical supply. Remove the motorized damper from the fresh air ductwork and inspect the 
damper blade for damage and proper function. If any debris is evident on the damper blade clean with a damp (not 
wet) cloth. DO NOT USE any detergents or abrasive materials for cleaning. Reinstall motorized damper to the fresh 
air ductwork and reseal joints. 

WARRANT Y

S&P USA - S&P Canada warrant that the MDX-ES24VK will be free from defective materials and workmanship for 
the period of (5) years from the date of original purchase. In the event that we find any part is defective the product 
will be repaired or, in the Company’s discretion, replaced without charge provided that the product has been installed 
in accordance with the enclosed instructions and all applicable EPA Standards and state and local building codes.
an such as: Improper Maintenance; Misuse; Negligence; Alteration; Abuse; Abnormal Use; or Accident or Incorrect 
Electrical Voltage and Current. 

Please visit SolerPalau-USA.com/sp-form/claims.html for additional details about warranty procedures.

 

Summary of Contents for MDX-ES24VK

Page 1: ...purpose of this manual is to aid in the proper installation and operation of fans manufactured by S P These instructions are intended to supplement good general practices and are not intended to cover detailed instruction procedures because of the wide variety and types of fans manufactured by S P Installation Operation and Maintenance Manual ...

Page 2: ......

Page 3: ...igorous standards of production All the components have been checked and tested at the end of the manufacturing process We recommend that you check the following after receiving this product 1 The correct size has been received 2 The correct model has been received 3 The details on the rating label correspond to the electrical supply voltage frequency etc Remove the unit from packaging and inspect...

Page 4: ...2 Make sure the temperature and humidity sensors are installed into the insulated fresh air duct between the wall cap and motorized damper if necessary ...

Page 5: ...te an air tight path from the building exterior to the ventilated space WIRING CAUTION Ensure that power is turned off and locked out before making any wiring connections The MDX ES24VK operates from a standard 24V 60Hz AC electrical supply There are multiple wiring scenarios available depending on the installer preferences The diagrams below show 3 common scenarios where the ES24V is connected ei...

Page 6: ...red continuous CFM based on the ventilation code ASHRAE 62 2 2010 Required Continuous CFM 0 01 Floor Area in ft 7 5 of bedrooms 1 Example 2 000 sqaure foot dwelling 3 bedrooms 50 CFM continuous ASHRAE 62 2 2013 2016 Required Continuous CFM 0 03 Floor Area in ft 7 5 of bedrooms 1 Example 2 000 sqaure foot dwelling 3 bedrooms 90 CFM continuous Now that the required continuous CFM is known calculate ...

Page 7: ... To inspect the unit disconnect from electrical supply Remove the motorized damper from the fresh air ductwork and inspect the damper blade for damage and proper function If any debris is evident on the damper blade clean with a damp not wet cloth DO NOT USE any detergents or abrasive materials for cleaning Reinstall motorized damper to the fresh air ductwork and reseal joints WARRANTY S P USA S P...

Page 8: ...Install the sensors at a location so that they will be exposed to the fresh air intake ex the fresh air ductwork Drill 2 3 4 diameter holes spaced appropriately and install the sensors with the provided hardware NOTE the sensor wires can be extended up to 300 feet without deviation Use appropriate duct tape to seal joints openings as necessary DIMENSIONS in SCREEN DIAGRAM OPERATING MODES OFF Mode ...

Page 9: ...C to 55 C High Limit Temperature settings range 65 105 F 18 C to 40 C Low Limit Temperature settings range 20 60 F 6 C to 16 C Heater Temperature settings range 32 F 62 F 0 C 16 C Temperature resolution 1 F or 0 5 C Temperature Accuracy 1 F or 0 5 C Humidity measurement range 10 95 High Limit Humidity settings range 55 90 Low Limit Humidity settings range 10 50 Humidity resolution 1 Humidity Accur...

Page 10: ...owers Avenue Jacksonville Florida 32217 T 904 731 471 1 F 904 737 8322 www solerpalau usa com S P Canada Ventilation Products Inc 6710 Maritz Drive Unit 7 Mississauga ON L5W 0A1 Canada T 416 744 1217 F 416 744 0887 www solerpalaucanada com ...

Reviews: