1
Losone Select Inline Mount Ventilation
Model: L2000L
IN-LINE CABINET
VENTILATORS
READ AND SAVE THESE INSTRUCTIONS
WARNING
CAUTION
PLAN INSTALLATION
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY
TO PERSONS, OBSERVE THE FOLLOWING:
1. Use this unit only in the manner intended by the manufacturer.
If you have questions, contact the manufacturer at the address
or telephone number listed in the warranty.
2. Before servicing or cleaning unit, switch power off at service
panel and lock the service disconnecting means to prevent
power from being switched on accidentally. When the service
disconnecting means cannot be locked, securely fasten a
prominent warning device, such as a tag, to the service panel.
3. Installation work and electrical wiring must be done by a
qualified person(s) in accordance with all applicable codes
and standards, including fire-rated construction codes and
standards.
4. Sufficient air is needed for proper combustion and exhausting
of gases through the flue (chimney) of fuel burning equipment
to prevent backdrafting. Follow the heating equipment
manufacturer’s guideline and safety standards such as those
published by the National Fire Protection Association (NFPA),
and the American Society for Heating, Refrigeration and
Air Conditioning Engineers (ASHRAE), and the local code
authorities.
5. When cutting or drilling into wall or ceiling, do not damage
electrical wiring and other hidden utilities.
6. Ducted fans must always be vented to the outdoors.
7. This unit must be grounded.
1. For general ventilating use only. Do not use to exhaust
hazardous or explosive materials and vapors.
2. To avoid motor bearing damage and noisy and/or
unbalanced impellers, keep drywall spray, construction dust,
etc. off power unit.
3. Please read specification label on product for further
information and requirements.
Installer: Leave this manual
with the homeowner.
Homeowner: Use and Care
information on page 3.
EXHAUST
ACCESS
3/8” MIN.
THREADED ROD
(By Others)
PANEL
DUCT
FLANGES
ADJUSTABLE
BRACKET
INTAKE
INTAKE
ACCESS
PANEL
INTAKE DUCT
FLANGES
EXHAUST
DUCT FLANGE
EXHAUST
DUCT FLANGE
MOUNTING (In-line Configuration)
CONVERTING FROM
RIGHT-ANGLE TO INLINE
Converted for in-line applications.
Remove and reverse duct flanges and
access panel positions on housing.
For correct intake and exhaust duct size, see table below
Model
Intake Duct Size
Exhust Duct Size
L2000L
12-3/8”x 35-3/4”