background image

- Before assembling the device, check that the
turbine rotates freely.

For your extractor to work more efficiently:

Surface Assembly (fig. 2A):

- Do not use conduits whose diameter is less than
80 mm.
- If a flexible conduit is used, stretch it out fully
- Do not place elbows right at the extractor
discharge.
- Elbows should have as large a radius as
possible.

1. Make a 105-mm diameter hole in the wall or
ceiling, making sure that the device fits in the area
you have planned for it.
2. Remove the front cover (1) of the fan body (2)
pressing the clips (3) carefully with a small
screwdriver (fig.1B).
3. The fan body (2) is secured to the base frame
(4) by means of 4 screws and 4 clips.
To dismantle it, ove the 4 screws from the
corners and open the 4 clips (7).

Built-in assembly (fig. 2B):

4. Using 4 screws and plugs that are appropriate
for the kind of wall, fix the base frame (4) on to the
surface, ensuring that the circular profile of the
frame coincides with the opening made, so that
the discharge nozzle can be introduced easily
subsequently.
5. Open the connections cover (5) of the fan
body and pass the cable through the hole
provided for this purpose on the bottom of the
terminal box.
6. Reassemble the fan body (2) on to the base
frame (4) by introducing it into the flanges and
securing it with the 4 screws.
7. Connect to the terminals passing the cable
through as indicated in figure. 3.
8. Follow the electrical diagram applying to the
EBB version that is being installed (fig. 5 to 8).
9. Close the connections cover (5) with the
screw.
10.Assemble the front cover (1) again, pressing
the upper and lower clips and pressing each
corner down to ensure that it fits properly in place.
11.Turn the extractor on to check that it works
properly.

1. Use the template to mark and cut the panel
into which the device will be installed. Read the
instructions given on the template carefully.
2. Follow steps 1, 2 and 3 of the Surface
Assembly Instructions.
3. Open the connections cover (5) and pass the
cable through the hole provided for this purpose
on the bottom of the terminal box.

ENGLISH

EBB CENTRIFUGAL EXTRACTOR

SAFETY RECOMMENDATIONS

INSTALLATION
IMPORTANT: Before proceeding with the
installation and connection of the device,
make sure to disconnect the electricity
supply.

Figure 1A:

EBB series extractors have been manufactured
according to strict production and quality control
standards such as ISO 9001. All the components
have been verified and all the devices have been
tested following assembly.
We recommend you to check the following points
when you receive this extractor:
1- Make sure you have received the right model
2- Make sure that the data on the nameplate are
appropriate to your needs: voltage, frequency,
speed, etc.

The installation must be carried out in
accordance with current regulations in each
country.
- The installation must be carried out by a
qualified professional.
- The electrical installation must incorporate an
omnipolar switch with an opening between
contacts of at least 3 mm, appropriate for the load
and complying with current standards.
- In bathrooms, the device must be installed
outside the reach of any person taking a shower
or a bath and the switch must be installed outside
the bathroom.
- Do not use these fans in explosive or corrosive
atmospheres. If the EBB is working in a kitchen
where there is a boiler or any other kind of
combustion device that needs air to work, check
that the air inlets to the kitchen are sufficient.
- The extractor discharge cannot be connected to
a conduit for the evacuation of smoke from
devices worked by gas or any other fuel.
- In the event of considerable humidity, you are
advised to install the discharge conduit
horizontally, with a slight outwards slant.

1- Front cover
2- Fan body
3- Front cover clip
4- Base frame
5- Connections cover
6- Slots
7- Retainers
8- Discharge flange

80 mm

9- Discharge flange

100 mm

EBB series fans must be installed in an area that

is sheltered from meteorological conditions; they
can be assembled either in vertical or horizontal
position.

The extractor is designed to be connected to a

80 or 100-mm diameter duct.

-

-

4. Connect the duot to the discharge flange (8-9).

5. Secure the fan body (2) using 4 screws and
plugs that are appropriate for the kind of surface.
6. Connect to the terminals, passing the cable
through as indicated in figure 3.

Summary of Contents for EBB series

Page 1: ...EBB 100 N...

Page 2: ...Fig 1B Fig 2A Fig 2B 8 4 7 6 3 3 6 7 2 5 1 9 Fig 1A...

Page 3: ...N L N LB LA N LB LA Fig 5B Fig 6A REB N L N LB LA Fig 6B Fig 3 N LA LB L N N LB LA Fig 5A EBB S...

Page 4: ...80 90 70 60 HR T min EBB T EBB HT N L LS MODELOS T Fig 9A N L LS MODELOS HT Fig 9B Fig 7B N L Fig 8B N L Fig 7A N L N LS L N LS L N LS L N LS L Fig 8A N L 15 A 2 T min...

Page 5: ...abym nachyleniu na zewn trz In atow w w powietrzu o cechach wybuchowych lub korozyjnych WA NA UWAGA Przed przyst pieniem do instalacji i pod czenia urz dzenia pami taj o od czeniu pr du INSTALACJA 6...

Page 6: ...przy 2 pr dko ciach z prze cznikiem napi cia typu REB Rys 5A Rys 6A Rys 6B Funkcjonowanie z regulatorem Rys 7B Funkcjonowanie z prze cznikiem zw ocznym tak aby uruchamia si jednocze nie z w czeniem o...

Page 7: ...nie automatyczne z w czaniem wy czaniem si razem z prze cznikiem o wietlenia rys 8B Funkcjonowanie automatyczne podobne do przypadku 1 leczy urz dzenie w cza si nawet wtedy gdy poziom wilgotno ci w po...

Page 8: ...EBB CENTRIFUGALEXTRACTOR SAFETYRECOMMENDATIONS INSTALLATION IMPORTANT Before proceeding with the installation and connection of the device make sure to disconnect the electricity supply Figure 1A EBB...

Page 9: ...e EBB works at slow speed In order to modify the factory settings the potentiometers situated beside the connections cover fig 9B will have to be operated These potentiometers are fragile and must be...

Page 10: ...omaly in the operation of the device contact an official authorised service or the seller of the product If the device is handled by persons who are not authorised by S P the guarantee will be cancell...

Reviews: