22 

6.

 

MAINTENANCE 

 

Before manipulating the device, make sure that it is disconnected it from the mains and that no one can turn it on 

during the activity. 
The unit must be regularly inspected. These inspections should be carried out in order to avoid dirt or dust 

accumulating on the impeller, motor or back-draught shutter. This could be dangerous and may shorten the working 

life of the unit.  
While cleaning, great care should be taken not to unbalance the impeller or motor.  
In all maintenance and repair work, the safety regulations in force in each country must be observed. 
 

7.

 

WARRANTY 

S&P Limited Warranty 
24 (TWENTY-FOUR) MONTH PRODUCT WARRANTY 
S&P UK Ventilation Systems Limited warrants that the DUOVENT heat-recovery unit will be free from defective 

materials and workmanship for the period of 24 (twenty-four) months from the date of original purchase.  In the 

event that we find any part is defective the product will be repaired or at the company’s discretion, replaced without 

charge provided that the product has been installed in accordance with the enclosed instructions and all applicable 

standards and national and local building standards. 
IF CLAIMING UNDER WARRANTY 
Please return the completed product, carriage paid, to your local authorized distributor.  All returns must be 

accompanied by a valid Invoice of Sale.  All returns must be clearly marked “Warranty Claim”, with an accompanying 

description stating the nature of the fault. 
THE FOLLOWING WARRANTIES DO NOT APPLY 

 

Damages resulting from improper wiring or installation. 

 

Damages resulting when using the fan/control with fans/motors/controls/sensors other than those supplied 

and manufactured by the S&P Group of Companies. 

 

Removal or alteration of the S&P data plate label. 

WARRANTY VALIDATION 

 

The end user must keep a copy of the Invoice of Sale to verify a purchase date. 

 

8.

 

RECYCLING 

Dismantling and recycling must be carried out by qualified personnel and in compliance with local and international 

regulations. 
Disconnect the electrical equipment from the power supply making sure that no one can start it during the operation. 
Disassemble and eliminate the parts to be replaced according to current national and international standards. 

EEC legislation and our consideration of future generations mean that we should always recycle 

materials where possible; please do not forget to deposit all packaging in the appropriate recycling 

bins. If your device is also labelled with this symbol, please take it to the nearest Waste Management 

Plant at the end of its serviceable life. 

Summary of Contents for Duovent Series

Page 1: ...1 UK WIRING GUIDE TO BE USED IN CONJUNCTION WITH THE MAIN INSTRUCTION MANUAL...

Page 2: ...2...

Page 3: ...REE CONTACT 7 4 3 S P AIRSENS BOOST 8 4 4 0 10V CONTROL BMS 9 4 5 S P AIRSENS RH 0 10V 10 4 6 AIRSENS CO2 VOC 0 10V 11 4 7 SCHT AD 0 10V CO2 12 4 8 SCHT AD 0 10V RH 13 4 9 SCO2 A 0 10V CO2 14 4 10 SHT...

Page 4: ...ss the instruction book on to the end user Please check that the equipment is in perfect condition when you unpack it since any factory defect is covered under the S P guarantee Please also check that...

Page 5: ...5 3 POWER WIRING 3 1 230V POWER WIRING 3 2 400V POWER WIRING...

Page 6: ...6 4 CONTROL WIRING 4 1 REMOTE ENABLE VOLT FREE CONTACT...

Page 7: ...7 4 2 BOOST VOLT FREE CONTACT...

Page 8: ...ree variations relative humidity RH carbon dioxide CO2 and volatile organic compounds VOC Below lists the product descriptions and codes to be ordered Please read this instruction booklet in conjuncti...

Page 9: ...0 10V CONTROL BMS Fan speed The speed is defined by a 0 10V input when the control signal is received it will proportionally increase or decrease the speed of the fans depending on the input control v...

Page 10: ...n the humidity in the air NOTE The AIRSENS is a S P accessory which can be purchased there are three variations relative humidity RH carbon dioxide CO2 and volatile organic compounds VOC Below lists t...

Page 11: ...ants in the air NOTE The AIRSENS is a S P accessory which can be purchased there are three variations relative humidity RH carbon dioxide CO2 and volatile organic compounds VOC Below lists the product...

Page 12: ...r which will proportionally increase and decrease its control voltage depending on the pollutants in the air NOTE The SCHT is a S P accessory which can be purchased using the product code 5416731100 P...

Page 13: ...or which will proportionally increase and decrease its control voltage depending on the humidity in the air NOTE The SCHT is a S P accessory which can be purchased using the product code 5416731100 Pl...

Page 14: ...which will proportionally increase and decrease its control voltage depending on the pollutants in the air NOTE The SCO2 A is a S P accessory which can be purchased using the product code 5401221000...

Page 15: ...which will proportionally increase and decrease its control voltage depending on the pollutants in the air NOTE The SHT A is a S P accessory which can be purchased using the product code 5416803900 P...

Page 16: ...16 4 11 FIRE SHUTDOWN...

Page 17: ...s Fault Number Description 1 Electrical heater over heating 2 Antifreeze protection of water heating 3 Supply fan error 4 Exhaust fan error 5 Regenerator freezing 6 Temperature sensor error Supply SUP...

Page 18: ...18 5 1 RUN RELAY Run Relay Run relay will activate when fan is in normal running conditions below is the operation Fan Running Closed circuit Fan Stopped Open circuit...

Page 19: ...19 5 2 FAULT RELAY Fault Relay Fault relay will activate when either fan is in fault condition below is the operation Fan Running Stopped Open circuit Fault with Fan Closed circuit...

Page 20: ...20 5 3 FILTER RELAY Filter Relay Filter relay will activate when the filters are in a poor condition below is the operation Clean Filters Open circuit Dirty Filters Closed circuit...

Page 21: ...21 5 4 SENSOR RELAY Sensor Relay Sensor relay will activate in the event of a fault sensor below is the operation No Fault Open circuit Fault Closed circuit...

Page 22: ...RANTY Please return the completed product carriage paid to your local authorized distributor All returns must be accompanied by a valid Invoice of Sale All returns must be clearly marked Warranty Clai...

Page 23: ...23...

Page 24: ...24 S P UK VENTILATION SYSTEMS LTD S P HOUSE WENTWORTH ROAD RANSOMES EUROPARK IPSWICH SUFFOLK TEL 01473 276890 WWW SOLERPALAU CO UK REF REV 1...

Reviews: