Ventilation units with heat recuperation
DUOVENT
®
MODULAR DV/RV
14
DUOVENT
®
MODULAR RV:
Nominal
flow
voltage
heater
efficiency*
Inlet/exhaust fan
cooler
power*
unit max.
air flow**
control
system
weight*** weight**
(without
MX)
* (with
MX)
Type
power*
current
max. input
current
Digireg
®
power
[W]
[m
3
/h]
[A]
[kW]
[A]
[m
3
/h]
[V/Hz]
[kW]
[%]
[kg]
[kg]
8500
–
–
–
8500 DCA
61.1
–
–
832
to
917
860
to
951
8500 DCB
43.1
–
–
M3-Vx
3×400V
50Hz
7800
3653/2521
5.3/3.6
75.7
9000
8500 DCA DCC
61.1
–
62.2
8500 DCA DX
61.1
–
66.2
8500 DI
30.0
43.3
–
M3-E36
10100
10100 DCA
10100 DCB
10100 DCA DCC
10100 DCA DX
10100 DI
–
–
–
965
to
1072
996
to
1109
3×400V
50Hz
M3-Vx
9300
4228/3152
6.1/4.6
76.2
11500
45.0
65.0
–
M3-E72
–
12000
–
–
12000 DCA
92.2
–
–
1176
to
1302
1224
to
1357
12000 DCB
63.3
–
–
3×400V
50Hz
M3-Vx
11500
5183/3780
7.5/5.5
75.9
13500
12000 DCA DCC
92.2
–
95.2
12000 DCA DX
92.2
–
96.9
12000 DI
45.0
65.0
–
M3-E72
14500
14500 DCA
14500 DCB
14500 DCA DCC
14500 DCA DX
14500 DI
–
111.0
76.4
111.0
111.0
60.0
–
–
–
–
–
86.6
–
–
–
115.0
115.0
–
1389
to
1544
1441
to
1604
3×400V
50Hz
M3-Vx
13600
6129/4531
8.9/6.6
75.1
16500
M3-E72
* at nominal air flow, t
e
= -12 °C/90 % r.h., t
i
= 22 °C/50 % r.h., t
e
= 35 °C/35 % r.h. (SUMMER), temperature rotor
** for arrangement - inlet: filter F7 + RV + DCB, outlet: filter M5 + RV
*** in relation to the unit accessory (without I&C)
Water cooler power DCC for t
e
= 35 °C/35 % r.h., t
w
= 6/12 °C. Water heater power DCA for t
e
= 10 °C, t
w
= 80/60 °C.
Water heater power DCB for t
e
= 10 °C, t
w
= 45/35 °C. Direct evaporating unit power DX for R410A coolant, t
e
= 35 °C/35 % r.h., t
vyp
= 6 °C.
3.5 OPERATION CONDITIONS
The unit can be used in rooms normal according to IEC 60364-5-51, resp.
ČSN 332000-5-51 ed. 3, ČSN 332000-1 ed.2. The ambient
temperature must be between -20 and +40 °C.
The unit can transport air without solid, fibrous, sticky, aggressive chemical and explosive additives. The maximum permissible supply air
temperature must not 40 °C. The maximum humidity of the air flowing through the unit is 17 g / kg s.v. (84 % r.h. at 25 °C).
If, due to the immediate climatic conditions, the humidity of the outdoor intake air reaches 100 % r.h. (wet steam), it is at the operator's discretion
whether to keep the unit running with the risk of temporary separation of moisture on the internal parts
of the unit (eg filters, flaps,…). This
humidity cannot be the subject of a complaint.
CAUTION!
!
Units with direct evaporator (marked DX and DXr in the unit code) must be equipped with a mixing flap (MX in the unit code)
ensuring as needed the min. temperature at the condenser/evaporator inlet temperature of +10 °C.
CAUTION!
For units with a direct evaporator (marked DX and DXr in the unit code), the
design air flow through the unit must be
observed
when operating the direct evaporator/condenser. It is acceptable to reduce the flow in cooling and heating mode by a
!
maximum of 20 % of the design air flow. For proper operation of the direct evaporator, it is necessary to observe the necessary
heat or cold consumption from the heat exchange surface of the evaporator/condenser. If the design amount of energy is not
consumed, the condensing unit / heat pump may report a fault in the pressure protections (LP, HP) of the cooling circuit and the
condensing unit / heat pump may cycle in ON/OFF mode.
75.7
–
–
53.1
–
–
75.7
–
77.3
75.7
–
80.9