background image

 
 

360 Herndon Parkway 

 Suite 

1400 

 

Herndon, VA 20170 

 http://www.rheintech.com 

 

SanDisk Corporation 

 

 

 

 

 

 

 

 

           Page 16 of 17 

DoC Report 
2006137 
02/02/07 

EMISSIONS EQUIPMENT LIST 

 
The following is a list of equipment Rhein Tech uses to perform testing. 
 

Part Type 

Manufacturer 

Model 

Serial 

Number 

Barcode 

Cal Due 

Date 

Conducted Emissions (SR2, SA3) 

Spectrum Analyzer (100Hz-.15GHz) 

Hewlett Packard 

8567A 

2727A00535 

900897 

3/3/2007 

Spectrum Analyzer Display Section 

Hewlett Packard 

85662A 

2816A16471 

900896 

3/3/2007 

Quasi-Peak Adapter 

Hewlett Packard 

52022-910E 

119044-189 

900099 

3/7/2007 

Filter Solar 

8130 

947306 

900729 

N/A 

16A LISN 

AFJ International 

LS16/110VAC 

16010020082  901084 

1/23/2007 

16A LISN 

AFJ International 

LS16/110VAC 

16010020080  901083 

3/29/2007 

Current Probe (Telecom conducted) Fischer 

Custom 

Communications 

F-33-1 3003 

900894 

3/22/2007 

Emissions testing software 

Rhein Tech Laboratories, Inc.  Automated Emission 

Tester 

Rev. 14.0.2 

N/A 

N/A 

Radiated Emissions 

RF Preselector for HP 8566B or 8568B (20Hz-
2GHz) 

Hewlett Packard 

85685A 

3146A01309 

900889 

4/12/2007 

Spectrum Analyzer (100Hz-.15GHz) 

Hewlett Packard 

8567A 

2727A00535 

900897 

3/3/2007 

Spectrum Analyzer Display Section 

Hewlett Packard 

85662A 

2816A16471 

900896 

3/3/2007 

Quasi-Peak Adapter 

Hewlett Packard 

52022-910E 

119044-189 

900099 

3/7/2007 

Amplifier RTL 

PR-1040 

1003 

900811 

3/15/2007 

Bi-Log Antenna (20MHz-2GHz) 

Schaffner Chase 

CBL6112B 

2648 

901053 

11/1/2007 

Spectrum Analyzer (100Hz-22GHz) 

Hewlett Packard 

8566B 

3138A07771 

900931 

9/13/2007 

Spectrum Analyzer Display Section 

Hewlett Packard 

85662A 

3144A20839 

900930 

9/13/2007 

Horn Antenna (2.0 – 4.0 GHz) 

EMCO 

3161-02 

9804-1044 

900772 

5/20/2007 

Horn Antenna (4.0 - 8.2 GHz) 

EMCO 

3161-03 

9508-1020 

900321 

5/20/2007 

Horn Antenna (8.2 - 12.4 GHz) 

EMCO 

3161-07 

9605-1054 

900323 

5/20/2007 

Horn Antenna (12.4 - 18 GHz) 

EMCO 

3160-08 

9607-1044 

900356 

5/20/2007 

1 – 26.5 GHz Pre-Amplifier 

Hewlett Packard 

8449B OPT H02 

31764-48 

900932 

5/13/2007 

Emissions testing software 

Rhein Tech Laboratories, Inc.  Automated Emission 

Tester 

Rev. 14.0.2 

N/A 

N/A 

Summary of Contents for SSD UATA 5000

Page 1: ...orporation 7 Atir Yeda Street Kfar Saba Israel Phone 972 9 7644908 Device Under Test SanDisk SSD UATA 5000 1 8 Document Number 2006137 Reference Number QRTL06 334 This report may not be reproduced except in full without the written approval of Rhein Tech Laboratories Inc ...

Page 2: ...g FCC Class B Compliance Standard s to which device was tested STANDARDS SPECIFIC TESTS APPLICABILITY Tested Not Tested CFR47 Parts 15 109 and 15 107 Radiated and Conducted Emissions Test Engineer Jon Wilson Signature Report Written By Jon Wilson Signature Report Approved By Desmond Fraser Signature Report Number 2006137 Report Date February 2 2007 Accredited by the National Voluntary Accreditatio...

Page 3: ...FIGURATION OF TESTED SYSTEM 7 3 PRODUCT LABELLING INFORMATION TO THE USER 8 3 1 DOC LABEL ON DEVICE 8 3 2 DOC STATEMENT IN USER S MANUAL 8 3 3 LOCATION OF LABEL ON EUT 8 4 CONDUCTED EMISSIONS 9 4 1 SITE AND TEST DESCRIPTION 9 4 2 CONDUCTED EMISSIONS TEST DATA 10 4 3 CONDUCTED TEST PHOTOGRAPHS 11 5 RADIATED EMISSIONS 12 5 1 SITE AND TEST DESCRIPTION 12 5 2 FIELD STRENGTH CALCULATION 13 5 3 RADIATED...

Page 4: ...ite 1400 Herndon Va 20170 Complete description and site attenuation measurement data has been placed on file with the Federal Communications Commission The power line conducted emission measurements were performed in a shielded enclosure also located at the Herndon Virginia facility Rhein Tech Laboratories is accepted by the FCC as a facility available to do measurement work for others on a contra...

Page 5: ...n RDT per Weibull method o Operating shock 1 500G 0 5msec half sine o Operating vibration 2 17G 7 800 Hz o Operating temperature 0 C to 70 C o Non operating temperature and storage 55 C to 95 C 2 2 MODIFICATIONS None 2 3 EUT EXERCISE DESCRIPTION The SanDisk SSD UATA 5000 1 8 was installed in a Class B laptop personal computer which was running Windows XP The computer was programmed to transfer fil...

Page 6: ...7 Auxiliary Equipment Part Manufacturer Model Serial Number FCC ID Cable Description RTL Bar Code Equipment Arrival Date Laptop PC Dell Latitude D420PP09S CND3520M69 DoC Unshielded Power 017739 01 08 2007 Laptop AC Adapter Dell LA65NS0 00 CN 0DF263 71615682 2ED4 N A Unshielded 017737 01 08 2007 DVD Player Dell PD01S CN OUC793 42940 68P 0053 DoC Shielded 017738 01 08 2007 Speaker harman kardon Mult...

Page 7: ...e 1400 Herndon VA 20170 http www rheintech com SanDisk Corporation Page 7 of 17 DoC Report 2006137 02 02 07 2 5 CONFIGURATION OF TESTED SYSTEM USB Termination DVD Player Speaker Microphone Laptop PC with SanDisk SSD UATA 5000 ...

Page 8: ...15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a part...

Page 9: ...ane and electrically connected to the peripheral LISN powers the EUT host peripherals The spectrum analyzer was connected to the A C line through an isolation transformer The 50 ohm output of the EUT LISN was connected to the spectrum analyzer input through a Solar 7 kHz high pass filter The filter is used to prevent overload of the spectrum analyzer from noise below 7 kHz Conducted emission level...

Page 10: ...0 7 34 0 56 0 22 0 46 0 12 0 Pass 3 950 Pk 34 2 1 1 35 3 56 0 20 7 46 0 10 7 Pass 17 670 Pk 25 1 2 5 27 6 60 0 32 4 50 0 22 4 Pass Phase Conductor Temperature 74 F Humidity 40 Emission Frequency MHz T e s t Detector Analyzer Reading dBuV S i t e Correction Factor dB Emission Level dBuV CISPR B QP Limit dBuV CISPR B QP Margin dBuV CISPR B AV Limit dBuV CISPR B AV Margin dBuV Pass Fail 0 157 Pk 46 9...

Page 11: ...360 Herndon Parkway Suite 1400 Herndon VA 20170 http www rheintech com SanDisk Corporation Page 11 of 17 DoC Report 2006137 02 02 07 4 3 CONDUCTED TEST PHOTOGRAPHS ...

Page 12: ...uency the EUT was rotated 360 and the antenna was raised and lowered from 1 to 4 meters in order to determine the emission s maximum level Measurements were taken using both horizontal and vertical antenna polarizations For frequencies between 30 and 1000 MHz the spectrum analyzer s 6 dB bandwidth was set to 120 kHz and the analyzer was operated in the CISPR quasi peak detection mode For emissions...

Page 13: ...Correction Factor SCF used in the above equation is determined empirically and is expressed in the following equation SCF dB m PG dB AF dB m CL dB SCF Site Correction Factor PG Pre amplifier Gain AF Antenna Factor CL Cable Loss The field intensity in microvolts per meter can then be determined according to the following equation FI uV m 10 FI dBuV m 20 For example assume a signal at a frequency of...

Page 14: ... Qp V 220 1 0 36 8 16 0 20 8 30 0 9 2 Pass 167 988 Qp V 300 1 4 39 1 16 1 23 0 30 0 7 0 Pass 191 990 Qp V 145 1 0 42 1 16 4 25 7 30 0 4 3 Pass 211 994 Qp V 330 1 0 32 6 16 1 16 5 30 0 13 5 Pass 249 994 Qp V 160 1 0 40 9 12 2 28 7 37 0 8 3 Pass 335 985 Qp V 190 1 0 37 3 9 4 27 9 37 0 9 1 Pass 365 785 Qp V 280 1 0 35 3 8 3 27 0 37 0 10 0 Pass 479 989 Qp H 269 2 2 36 4 4 6 31 8 37 0 5 2 Pass Note The...

Page 15: ...360 Herndon Parkway Suite 1400 Herndon VA 20170 http www rheintech com SanDisk Corporation Page 15 of 17 DoC Report 2006137 02 02 07 5 4 RADIATED TEST PHOTOGRAPHS ...

Page 16: ...ster Rev 14 0 2 N A N A Radiated Emissions RF Preselector for HP 8566B or 8568B 20Hz 2GHz Hewlett Packard 85685A 3146A01309 900889 4 12 2007 Spectrum Analyzer 100Hz 15GHz Hewlett Packard 8567A 2727A00535 900897 3 3 2007 Spectrum Analyzer Display Section Hewlett Packard 85662A 2816A16471 900896 3 3 2007 Quasi Peak Adapter Hewlett Packard 52022 910E 119044 189 900099 3 7 2007 Amplifier RTL PR 1040 1...

Page 17: ...ng the measurement procedure and test equipment that was used contained in the test report iv A description of the equipment under test EUT and support equipment connected to or installed within the EUT v The identification of the EUT and support equipment by trade name and model number and if appropriate by FCC identifier and serial number vi The types and lengths of connecting cables used and ho...

Reviews: