(6) 12-Gallon Indy Automotive Extractor with Heat
12-Gallon Indy Automotive Extractor with Heat (11)
8.0 Machine Parts List Continued
Drawing No.
Part No.
Item Description
Quantity
50
10-0852
1/4" 90 Degree Brass Elbow
1
51
10-1500-B
Heater Element 600 Watt
2
52
10-0814
Sensor for Extractor Heater
2
53
10-0814-B
Manual Sensor for Heater
2
54
10-0921
Aluminum Box Breakdown
55
10-0921
Aluminum Box for Dual Rod Heater
1
56
10-0204
Motor Mount Back-Up Washer
18
57
10-0379
8-32 x 3/8 Screw
8
58
10-0920
Dual Rod SS Heat Exchanger Tube
1
59
10-0379
8-32 x 3/8 Screw
8
60
10-0921
Part of Aluminum Box for Heater
61
10-0852
1/4" 90 Degree Brass Elbow
1
62
10-0802
Strain Relief for Heater
1
63
10-0901
175psi Relief Valve for Heater
1
64
80-0010
1/4" Brass Tee
1
65
10-0801-I
90 FPT for Sniper Heater
1
66
80-0101-M
1/4" Male Check Valve
1
67
10-0843
3/8" Black Hose for Extractor
6
68
10-0812
100psi Extractor Pump
1
69
80-0026
3/8 Barb x 1/4 MPT 90 Degree
1
70
10-0835-B
Pump Bolt 100psi Extractor
4
71
10-0843
3/8" Black Hose for Extractor
6
72
10-0868
1/4" Female QD for Extractor
2
73
10-0846
1/4" MPT Hex Nipple for Extractor
1
74
10-0801-J
90 MPT for Extractor Heater
1
75
80-0017
Bulk Head fitting for Extractor
1
76
80-0017
Bulk Head fitting for Extractor
1
78
10-0400-D
Keeper for Extractor Latch
1
79
10-0832
S/R Strap Bolts
4
80
10-0831
S/R Bracket for Extractor
2
81
10-0818
S/R Top of Tank Bolt on Extractor 1/4-20 x 1-1/8
Socket Head Cap Screw Stainless Steel
2
2.0 Grounding Instructions
DANGER: IMPROPER GROUNDING METHOD CAN RESULT IN A RISK OF
ELECTRIC SHOCK.
Electrical equipment must be grounded. If the machine should malfunction or breakdown,
grounding provides a path of least resistance for electrical current to reduce the risk of
electric shock. The Carpet Extractor is equipped with a cord containing a grounding
conductor and grounding plug. The plug must be inserted into an appropriate outlet that is
properly installed and grounded in accordance with all local codes and ordinances.
If repair or replacement of the cord or plug is necessary, DO NOT connect the grounded
wire to a flat bed terminal. The grounding wire is the wire with insulation and an outer
green surface, with or without yellow stripes.
Grounding Method
The equipment is for use on a normal 120 Volt circuit. It includes a grounded plug (plug
shown in Figure A). A temporary adapter (Figure B and C) may be used to connect this
plug into a 2-pole receptacle (Figure B) if a properly grounded outlet is not available.
The temporary adapter should be used only until a properly grounded outlet
(Figure A) can be installed by a qualified electrician. The green colored rigid ear lug or
the like extending from the adapter must be connected to a permanent ground, such as a
properly grounded outlet box cover. Whenever an adapter is used, it must be held in place
by a metal screw.
WARNING:
Improper connection of the equipment grounding conductor can result in a risk of
electric shock. Check with a qualified electrician or service person if you are in doubt
as to whether the outlet is properly grounded. DO NOT modify the plug provided with
the equipment. If the plug will not fit into the outlet, have a proper outlet installed by a
qualified electrician.
NOTE: In Canada, the use of a temporary adapter is not permitted by the Canadian
Electrical Code.