SANDIA aerospace STX 165 User Manual Download Page 4

The VFR Pushbutton is use to select the VFR Squawk code.  Pressing it a second time will 
recall the previous code.  

The VFR pushbutton has an additional function.  Pressing and holding it for three seconds 
will enlarge the squawk code display.  When in this mode the functions on the bottom portion 
of the display screen will no longer be displayed.  Pressing and holding the VFR Pushbutton 
for three seconds again will exit this mode.  This function is useful in high sunlight condi-
tions, particularly with bubble canopies.

When power is first applied to the STX 165, the 

SANDIA aerospace

 logo will be displayed along with the unit 

version number (the last two digits of the part number), the Display software version (D) and the Main software 
version (M).  The current software versions can be seen on the 

SANDIA aerospace

 web site at 

www.sandia.aero

IDT Pushbutton

The IDT is the Ident pushbutton and is depressed when requested by ATC to Ident.  The 
STX 165 remains in the Ident mode for 22.5 seconds.  When transmitting Ident, ID will be 
displayed in the left portion of the display.

2

Summary of Contents for STX 165

Page 1: ...STX 165 User Manual 3700 Osuna Road NE Suite 711 Albuquerque NM 87109 www sandia aero 306105 Rev A DRN434...

Page 2: ...ny means without the prior written consent of SANDIA aerospace Due to SANDIA aerospace s continued product and quality improvement programs information contained in this document is subject to change...

Page 3: ...ormal display page The power pushbutton is also used to start the counters This is explained in the counter section SBY The STX 165 is in standby mode and will not respond to radar interrogations ON T...

Page 4: ...unction is useful in high sunlight condi tions particularly with bubble canopies When power is first applied to the STX 165 the SANDIA aerospace logo will be displayed along with the unit version numb...

Page 5: ...ob and pushbutton Press the Enter Pushbutton the first digit in the squawk code will blink Rotate the smaller Data knob until the value of the codes first digit is displayed Rotate the larger Select k...

Page 6: ...et Up selection Icing Alert If an optional SANDIA aerospace STP 78 OAT probe is installed with the STX 165 it will display an Icing Alert in the upper right hand corner of the display when the tempera...

Page 7: ...NT UP at 0 00 Counter Up Counter Down The counter down CNT DOWN allows the pilot to enter a specific time and then be alerted when that time has expired This timer is especially useful for timed appro...

Page 8: ...ton Note that if the Enter Pushbutton is not pressed within ten seconds the STX 165 will exit the set up mode Note The STX 165 must be in SBY mode to enter the User Set Up Function The first page disp...

Page 9: ...ended If OFF is selected the pilot will be required to select the ON or ALT Mode The STX 165 starts with the EFT displayed in the lower right hand corner of the display The user can set the EFT to beg...

Page 10: ...instances a dif ferent code is desirable for the VFR squawk To change the VFR squawk code 1 Rotate the Data knob to select the DEFAULT VFR page 2 Press the Enter knob The brackets will extinguish and...