background image

 

Erwin Sander Elektroapparatebau GmbH           

Aquarientechnik 

Am Osterberg 22 

DE - 31311 Uetze-Eltze 

Tel : +49 5173 / 971-0 

Fax : +49 5173 / 971-197 

Internet: 

http://www.aqua-sander.de

 

E-mail: 

[email protected]

 

 

instruction manual 

 
 
 
 

Revision status 23.05.2016

 

 

Instructions 

 
 

 

 

Ozonizer 

XT 2000  

 
 
   

 

 

Summary of Contents for XT2000

Page 1: ...GmbH Aquarientechnik Am Osterberg 22 DE 31311 Uetze Eltze Tel 49 5173 971 0 Fax 49 5173 971 197 Internet http www aqua sander de E mail info aqua sander de instruction manual Revision status 23 05 201...

Page 2: ...ing and connecting the Ozonizer 7 Connecting the Ozonizer with Skimmer Ozone Reactor Operation with air stones 7 Alternative Connecting the Ozonizer with Skimmer with Injector 7 Start up procedure 8 O...

Page 3: ...e ozonizer has a power rating of 2000 mg ozone hour measured in dry air While used in damp surrounding air 40 80 air moisture the ozone performance may be diminished by 50 The ozonizer generates ozone...

Page 4: ...l data Ozone output 2000 mg h Voltage supply 100 to 240 VAC 50 60 Hz Power consumption 1 5 A Operating voltage ozone generator 24 VDC Scope of supply As soon as you have removed the device from its pa...

Page 5: ...alue is undershot the ozonizer is at risk of overheating Children from the age of 8 years as well as disabled or handicapped persons or persons with no or small technical experience may use the ozoniz...

Page 6: ...te the following are not covered by warranty Any damage resulting from misuse by misuse differing to the description in these instructions Any damage resulting from unauthorized repair disassembly imp...

Page 7: ...ack into the ozonizer Connecting the Ozonizer with Skimmer Ozone Reactor Operation with air stones The ozonizer has two tube connections The right connection 5 is connected to an air tube 6 x 1 leadin...

Page 8: ...e redox potential with a Sander redox measuring and regulating device which switches the ozonizer on and off automatically depending on the set target value Sander ORP Measurement and Controller devic...

Page 9: ...bar graph you can see the set ozone value in The ozone output can be reduced using the key The ozone output can be increased using the key When connecting a Redox measurement device When the redox set...

Page 10: ...ply unit Remove the power plug 3 from the ozonizer Remove the tubes from the tube connections Unscrew locking screws 2 of the connection plate 7 using a commercial hexagon socket wrench Remove cover f...

Page 11: ...rough the device during a maximum performance setting The ozonizer stops It will start up automatically after cooling down Fault High Voltage The ozone output can be reduced or interrupted through the...

Page 12: ...istration In interest of general environmental protection do not dispose of the device in domestic garbage but provide for an appropriate way of disposal You can be informed about garbage collecting p...