background image

   

SANDENVENDO AMERICA INC

 

1189085b ECN 52161 

 

 

 
 

Converting Temperature from °F to °C (or °C to °F) 

1.  Controller must be off. 
2.  While holding down the TIME button, press the On/Off button.  Software revision will be 
displayed.  
3.  Press and release the TIME button. 
4.  Wait 5 seconds. 
5.  Press any timer key once to change from °F to °C (or °C to °F). 
6.  Press the On/Off button to turn the unit on. 
7.  Verify the display indicates the desired temperature units (°F or °C). 
 

  

Heater Temperature Adjustment   

With controller power off, hold down the Time button, then press & release the Power button. 
The left timer button for a shelf decreases the temperature setpoint. 

 

The right timer button for a shelf increases the temperature setpoint.  
To exit heater temperature adjustment mode, press the power button. 
 
Buttons labeled as timers allow a temperature to be set, but have no effect on Mini HFD 

temperatures.  

 

  

Error Codes  

E30 

Inside ambient thermistor error (open circuit)  

E67 

Lower left shelf thermistor error (open circuit)  

E60 

Upper shelf thermistor error (open circuit)  

E63 

Middle shelf thermistor error (open circuit)  

E66 

Lower right shelf thermistor error (open circuit)  

E90 

Unable to read SD card 

 
Clear error codes by pressing any key (except for E90 error). 
Clearing an error code turns that shelf's heater off. 
Clear the E90 error by pressing the power button, then press again to turn HFD on again. 
 

  

Loading the

 

SD Card Program in the HFD controller 

With the HFD on: 

1.  Insert the SD card in the controller’s SD card slot until it clicks in place 
2.  The HFD display with show dashes while the program is loading 
3.  Loading will take up to 30 seconds 
4.  Once loaded, the display will revert to internal ambient temperature 
5.  Press (don’t pull) the card to remove it from the slot 

 

  

SD Card Programming 

The SD card must be formatted in FAT32, preferably by Windows XP instead of Vista.  It must 

contain a single file, and the file name does not matter. 512MB or 1GB cards only. The 
contents must be ASCII text as follows, in exactly the format shown: 

Summary of Contents for Vendo HFDM00001

Page 1: ...ENDO AMERICA INC 1189085b ECN 52161 1 MINI HOT FOOD DISPLAY Technical Service Manual MODEL HFDM00001 Table of Contents Commitment to Safety 2 Safety Warnings 3 Parts 4 Operation 5 Troubleshooting 8 Schematic 9 ...

Page 2: ...ndo predict all of the possible hazardous results The safety precautions outlined in this manual provide the basis for an effective safety program Use these precautions along with the service manual when installing or servicing the HFD We strongly recommend a similar commitment to safety by every servicing organization Only properly trained personnel should have access to the interior of the machi...

Page 3: ...electric shock or fire do not use volatile or flammable products in or near the HFD When moving the HFD turn the HFD off unplug and allow the unit to cool To prevent glass breakage and injury do not push on the glass Also use proper equipment and lifting techniques Insure the product doesn t tip while it is being moved If a lamp or any glass cracks or breaks turn off the power and discard all food...

Page 4: ...Front Door 1154538 Caution Hot Label 1182055 Middle Upper Shelf Rack Black 1158685 Side Gasket 1178052 Horizontal Rear Gasket 1166955 Side Glass no decal 1153213 Controller Membrane Pad 1165366 Right Decal 1153225 31 Controller 1178854 Lamp Guard 1178877 Lamp 1159513 Lamp Socket 1180812 Fan not shown 1182066 Bottom Rack Black 1178798 Shelf Guard 1165355 Left Decal 1180393 Shelf Assembly Other item...

Page 5: ...tton press cycles the timer back to one hour again Once the timer is activated the LED next to the shelf timer button becomes green The display then reverts to HFD internal ambient temperature display While a timer is on pressing a timer button once displays the remaining time for 4 seconds then shelf temperature for 4 seconds and then the display reverts to the internal ambient temperature displa...

Page 6: ...bient thermistor error open circuit E67 Lower left shelf thermistor error open circuit E60 Upper shelf thermistor error open circuit E63 Middle shelf thermistor error open circuit E66 Lower right shelf thermistor error open circuit E90 Unable to read SD card Clear error codes by pressing any key except for E90 error Clearing an error code turns that shelf s heater off Clear the E90 error by pressi...

Page 7: ...led by entering the following in the programming file example UL x Controller Connectors Modular three prong receptacle 115 VAC power Left and right below are viewed from the front or controller side of the Mini HFD J1 connector Heater and light power J2 connector Sensor signals J1 1 Lower Right Shelf Heater J2 1 Jumpered to J2 2 J1 2 Lower Right Shelf Heater J2 2 Jumpered to J2 1 J1 3 Middle Righ...

Page 8: ... securely installed Replace blown bulb s HFD internal ambient does not reach 150 F One or more heater plates not reaching temperature HFD needs approx 40 minutes to reach temperature at default setting Check plate temperature at controller see controller operation One or more Xenon lamp not functioning Check at terminal for resistance of 44 ohms 2 Check to ensure bulb is securely installed Replace...

Page 9: ...SANDENVENDO AMERICA INC 1189085b ECN 52161 9 SCHEMATIC Left Right as viewed from the front side or controller side of the Mini HFD 1181245 ...

Reviews: