Sanden Heat Pump – Owner’s Manual
Page 15 of 20
Technical data
Heat pump Unit Dimension
Unit: mm
Specification
Refrigerant type
R744
(
CO
2
)
Mass volume
740 g
Setting Outlet water temp
63
℃
Product weight
49 kg
MAX HEAT OUTPUT
6.0 kW
MAX RATED POWER INPUT
2.3 kW
Circuit Breaker Size
20A
Design Pressure
(
High/Low
)
14/9 MPa
Protection Raining Class
IPX4
MAX Operating water Pressure
700 kPa