Sanden Heat Pump – Installation Manual 

Page 11 of 32 

Electrical connections 

  Electrical installation should be done only by a licensed electrician who carries out 

the work according to the relevant regulations for electrical safety and wiring. 

  Follow the wiring rules for the breaker rating and the thickness of the electrical 

wiring. 

  Verify that the tank unit is full of water and the water stop cocks are open before 

turning on the power. 

System operation if connected to continuous power  

  The system runs its water heating cycle once a day to fill up the storage tank unit with 

heated water. 

  If the block out time function is selected (setting is covered on page 16) the unit will not 

operate during the block out times – this function is typically used on installations that 
have time of use electricity tariffs  

  The water heating cycle operation starts automatically when the residual hot water in 

the tank unit decreases.

 

  The system will not run if the electrical power supply is cut off. However, the system 

will automatically start operation, once the electricity becomes available. 

System operation if connected to off-peak electricity 

  There are no special settings for the off-peak connection. The system will run once the 

power becomes available and the temperature in the tank drops below the set point of 
the tank thermistor. If connecting the unit to off peak ensure that the off-peak tariff 
provides a minimum of 5 hours continuous power, as it can take at least four hours to 
fill the tank unit with hot water at installation. If the ambient temperature is lower than 
10

o

C this can be longer. 

  If the unit is connected to off peak power and hot water consumption has been is 

exceptionally high, hot water may not be available until the next power supply cycle.  

 

Daily frequency and amount of hot water consumption may also affect the duration of 
the heating cycle operation.

 

Select the electrical supply mode that best suits the customer’s hot water 
consumption. The type of off-peak connection may need to be changed if hot water 
supply is not maintained as required. 
 
Figure 9: Outline of electrical system connections 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Summary of Contents for GAUS-160FQS

Page 1: ...AU A45HPC This appliance is not to be used by persons sincluding children with reduced physical sensory or mental capabilities or lack of experience and knowledge unless they have been given supervisi...

Page 2: ...y Quality 21 Change of water supply 21 Technical data 22 Warranty Policy 26 Warranty Period 27 Post installation inspection checklist 27 Check sheet 28 MEMO 29 PATENTS This water heater may be protect...

Page 3: ...urrently available It s even more efficient when connected to off peak power1 and the noise level is so low it will operate unobtrusively throughout the night How it works The Sanden Eco Hot water Hea...

Page 4: ...plies with all the relevant standards Only a licensed person will have insurance protecting their workmanship for six years The unit has been specifically designed for domestic hot water heating and i...

Page 5: ...unit in an area which allows sufficient ventilation Poor ventilation may cause the unit to short cycle and this could increase the power consumption by more than 10 Do not install the heat pump unit i...

Page 6: ...ess there is a likelihood of high wind or local vibration If the heat pump unit and tank unit are fixed appropriate fixing devices should be used A pressure and temperature relief PTR valve is include...

Page 7: ...not be connected to a solar water heater The piping must be insulated using insulation having a thermal conductivity no greater than 0 04 W m K and minimum thickness of 25 mm If the piping needs brazi...

Page 8: ...n to the tank unit fitting marked Hot return Connect the mains water supply to the lower fitting on the tank unit marked Cold Water Inlet Connect the hot water supply pipe to the top of the tank unit...

Page 9: ...will automatically go back to the clock display mode than 5 minutes Open the hot water taps in the home to remove air Close the hot water taps in the home after no air is confirmed in the water Figur...

Page 10: ...Wrap the freeze protection heater up to the water connectors of the main unit Ensure the freeze protection heaters are connected to 24 hours continuous power supply It is important to fully explain ho...

Page 11: ...al power supply is cut off However the system will automatically start operation once the electricity becomes available System operation if connected to off peak electricity There are no special setti...

Page 12: ...the piping cover and screw clamp fitting Connect the power supply line to the terminal block Hold the power supply line below the terminal block with the screw clamp fitting Connect the thermistor ca...

Page 13: ...the grey cable inside the black conduit Expose the 2 thermistor wires black white Note that wires from thermistor in tank are black black Strip the 2 wires ready for the terminal block remove the fin...

Page 14: ...tting Mode Time Display starts flashing once the mode is switched 2 Setting the Clock The time setting can be adjusted by pressing Up and Down keys Fast forward and rewind are available by pressing an...

Page 15: ...stallation Manual Page 15 of 32 Figure 12 How to operate the controller How to remove the operation panel 1 Remove Top Panel 4 screws 2 Remove the screw 3 Pull up Operation Panel Pull up Operation Pan...

Page 16: ...ps flashing The end time display starts flashing at the same time Adjust block out end time Set to the desired end time by using Up and Down keys Setting can be performed only in hour increments not i...

Page 17: ...ving mode How to switch to Maintenance Mode Press and hold down Up and Down keys together in the clock display mode to go to the maintenance mode After the mode is switched press the Enter key to sele...

Page 18: ...trol PCB in the heat pump unit for any disconnect fall off wire breakage or short circuit Measure resistance of the thermistor indicated by the error code HC HP water outlet temperature thermistor err...

Page 19: ...e resistance of the discharged thermistor Measure resistance of coil of expansion vale to check open or short circuit Replace the main PCB or heat pump P4 Module temperature thermistor error Replace t...

Page 20: ...e discharged thermistor Replace the main PCB or heat pump Notes 1 After a component is replaced or the inspection is completed turn the unit on off several times to confirm the error does not re occur...

Page 21: ...e to the dissolution of atmospheric contaminants Water with a pH less than 6 5 may be treated to raise the pH It is recommended that an analysis of the water from a rainwater tank be conducted before...

Page 22: ...nit mm Specification Refrigerant type R744 CO2 Mass volume 740 g Setting Outlet water temp 63 Product weight 49 kg MAX HEAT OUTPUT 6 0 kW MAX RATED POWER INPUT 2 3 kW Circuit Breaker Size 20A Design P...

Page 23: ...Sanden Heat Pump Installation Manual Page 23 of 32 Hot water storage tank unit REFER Drawing provided with tank...

Page 24: ...Sanden Heat Pump Installation Manual Page 24 of 32 315L 300L 250L 160L...

Page 25: ...Sanden Heat Pump Installation Manual Page 25 of 32 Wiring Diagram...

Page 26: ...rdance with the guidelines in the Sanden Heat Pump Water Heater System literature Warranty Exclusions 1 Repair and replacement work will be carried out as set out in the Sanden Heat Pump Water Heater...

Page 27: ...sions stated above your Sanden Heat Pump Water Heater System is warranted in a Residential application as follows Heat pump unit Sanden warrants all parts labour on the SANDEN water heater system for...

Page 28: ...h the installation manual Around the piping Action Completed A dedicated water supply stop cock is mounted The metal piping for the hot water supply has been properly insulated There is no water leaki...

Page 29: ...MEMO...

Page 30: ......

Page 31: ......

Page 32: ...SANDEN Heat Pump 40980 44913 Installation Manual AU...

Reviews: