S&C Scada-Mate SD Installation And Operation Manual Download Page 2

2

    S&C Instruction Sheet 775-510

Introduction

Qualified Persons

 WARNING

Only qualified persons who are knowledgeable in the installation, operation, and 
maintenance of overhead and underground electric distribution equipment, along 
with all associated hazards, may install, operate, and maintain the equipment 
covered by this publication . A qualified person is someone who is trained and com-
petent in:
•  The skills and techniques necessary to distinguish exposed live parts from nonlive 

parts of electrical equipment

•  The skills and techniques necessary to determine the proper approach distances 

corresponding to the voltages to which the qualified person will be exposed

•  The proper use of special precautionary techniques, personal protective  

equipment, insulated and shielding materials, and insulated tools for working on 
or near exposed energized parts of electrical equipment

These instructions are intended ONLY for such qualified persons . They are 
not intended to be a substitute for adequate training and experience in safety  
procedures for this type of equipment .

Read this  

Instruction Sheet

NOTICE

Thoroughly and carefully read this instruction sheet and all materials included in 
the product’s S&C Instruction Handbook before installing or operating an S&C  
Scada-Mate SD Switching System . Familiarize yourself with the Safety Information 
and Safety Precautions on pages 3 through 5 . The latest version of this publication 
is available online in PDF format at 

sandc.com/en/support/product-literature/ .

Retain this  

Instruction Sheet

This instruction sheet is a permanent part of your S&C Scada-Mate SD Switching System. 
Designate a location where you can easily retrieve and refer to this publication.

Proper Application

 WARNING

The equipment in this publication is only intended for a specific application . 
The application must be within the ratings furnished for the equipment . Ratings 
for the S&C Scada-Mate SD Switching System are listed in the ratings table in  
Specification Bulletin 775-31 . The ratings are also on the nameplate affixed to the 
product .

Warranty

The warranty and/or obligations described in S&C’s Price Sheet 150, “Standard Conditions 
of Sale – Immediate Purchasers in the United States” (or Price Sheet 153, “Standard 
Conditions of Sale – Immediate Purchasers Outside the United States”), plus any special 
warranty provisions, as set forth in the applicable product-line specification bulletin, 
are exclusive. The remedies provided in the former for breach of these warranties shall 
constitute the immediate purchaser’s or end user’s exclusive remedy and a fulfillment of 
the seller’s entire liability. In no event shall the seller’s liability to the immediate purchaser 
or end user exceed the price of the specific product that gives rise to the immediate 
purchaser’s or end user’s claim. All other warranties, whether express or implied or 
arising by operation of law, course of dealing, usage of trade or otherwise, are excluded. 
The only warranties are those stated in Price Sheet 150 (or Price Sheet 153), and THERE 
ARE NO EXPRESS OR IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS 
FOR A PARTICULAR PURPOSE. ANY EXPRESS WARRANTY OR OTHER OBLIGATION 
PROVIDED IN PRICE SHEET 150 (OR PRICE SHEET 153) IS GRANTED ONLY TO THE 
IMMEDIATE PURCHASER AND END USER, AS DEFINED THEREIN. OTHER THAN AN 
END USER, NO REMOTE PURCHASER MAY RELY ON ANY AFFIRMATION OF FACT OR 
PROMISE THAT RELATES TO THE GOODS DESCRIBED HEREIN, ANY DESCRIPTION 
THAT RELATES TO THE GOODS, OR ANY REMEDIAL PROMISE INCLUDED IN PRICE 
SHEET 150 (or PRICE SHEET 153.)

Summary of Contents for Scada-Mate SD

Page 1: ...eplacement Instructions and Labels 3 Location of Safety Labels and Tags 4 Safety Precautions 5 Shipping and Handling Packing 6 Inspection 6 Handling 7 Installation Inserting Pole Mounting Hardware 8 S...

Page 2: ...retrieve and refer to this publication Proper Application WARNING The equipment in this publication is only intended for a specific application The application must be within the ratings furnished for...

Page 3: ...cautions are not followed NOTICE NOTICE identifies important procedures or requirements that can result in product or property damage if instructions are not followed Following Safety Instructions If...

Page 4: ...ads may be energized from either side and in any position G 6812 D WARNING Electrocution Hazard Switch and control unit enclosure must be installed and grounded ONLY by qualified personnel G 6815 E WA...

Page 5: ...Switching Systems contain fast moving parts that can severely injure fingers Do not remove or disassemble operating mechanisms or remove access panels on the Scada Mate SD switch base unless directed...

Page 6: ...ese values must be programmed into the remote terminal unit RTU installed with the switch if applicable to apply correction for the unit to unit variations in the sensors The S C Sensor information is...

Page 7: ...EP 2 Secure the lifting slings to the switch before unbolting the switch from the crate Remove all packing materials before lifting the switch Shipping and Handling Lifting bracket extended NOTICE Do...

Page 8: ...erline distance of the holes must be 14 inches 356 mm STEP 4 Insert two inch diameter through bolts not furnished in the holes drilled in Step 3 Secure these bolts loosely with necessary washers and n...

Page 9: ...to uncrate the switch before lifting may cause damage to the switch or personal injury Installing the Optional Pole Band and J Bolts Conduct the following steps to install the optional pole band and...

Page 10: ...ting the end of a number 2 AWG wire or two number 6 AWG wires or wires having an equivalent cross sectional area to the grounding lug on the pole saddle See Figure 6 Insert the ground wire into the gr...

Page 11: ...ors on the terminal pads use the following procedure to prepare their surfaces STEP 10 Do not wire brush Scada Mate SD switch terminal pads They are plated and wire brushing will scratch the protectiv...

Page 12: ...to the terminal pads For installation instructions refer to S C Drawing RD 6794 STEP 13 To install the optional wildlife protection components first prepare the surfaces of the terminal pads and conn...

Page 13: ...Mate SD switches STEP 15 Ground the enclosure by solidly connecting one number 6 AWG wire or wires of equivalent cross sectional area to the ground lug on the back of the enclosure Solidly connect th...

Page 14: ...ol unit Locate the connector receptacle on the front of the switch base and remove the dust cover c Remove the sensor shorting blocks from the receptacle and attach the control cable plug d Secure the...

Page 15: ...rol cable at the drip loop and at the switch connection b Attach the control cable along the length of the utility pole and secure the control cable to the utility pole using suitable guards or clamps...

Page 16: ...Electric Company Use the following procedure to energize the power operated switch STEP 20 After making all user connections to the control unit if applicable in accordance with the S C instruction sh...

Page 17: ...remote operation STEP 22 Place the LOCAL REMOTE switch inside the control unit in the Remote position Refer to the instructionsheetfurnishedwiththecontrolunit The Scada Mate SD switch can now only be...

Page 18: ...ow the procedure below using a conventional insulated hookstick or S C Universal Pole and Pole Extension if required fit ted with a heavy duty hook tool such as the S C Substation Prong or equivalent...

Page 19: ...gency Manual Operation STEP 26 Scada Mate SD Switches are capable of manual interrupter operation In the event of electrical power loss a standard or extendible hookstick is used to open and close the...

Page 20: ...uffix W slide the tap cover backfarenoughtogainaccesstotheterminalpads Then remove the upper and lower terminal pad covers to permit the removal of the phase conductors Retain the covers for reinstall...