
CW-
CW-
CW-
CW-6080
6080
6080
6080////6180
6180
6180
6180////6280
6280
6280
6280 S
S
S
Series
eries
eries
eries
7
2.
2.
2.
2.
Restore
Restore
Restore
Restore to
to
to
to factory
factory
factory
factory settings
settings
settings
settings
Before
Before
Before
Before machine
machine
machine
machine startup,
startup,
startup,
startup, please
please
please
please press
press
press
press and
and
and
and hold
hold
hold
hold
▲
▼
▼
▼
▼ button
button
button
button until
until
until
until the
the
the
the
controller
controller
controller
controller displays
displays
displays
displays rE,
rE,
rE,
rE, 6
6
6
6 seconds
seconds
seconds
seconds later
later
later
later after
after
after
after releasing
releasing
releasing
releasing the
the
the
the button,
button,
button,
button, the
the
the
the
controller
controller
controller
controller works
works
works
works in
in
in
in normal
normal
normal
normal order.
order.
order.
order. Then
Then
Then
Then all
all
all
all parameters
parameters
parameters
parameters settings
settings
settings
settings of
of
of
of the
the
the
the
controller
controller
controller
controller have
have
have
have been
been
been
been restored
restored
restored
restored to
to
to
to factory
factory
factory
factory settings.
settings.
settings.
settings.
3.
3.
3.
3.
Alarm
Alarm
Alarm
Alarm function
function
function
function
(1)
(1)
(1)
(1) Alarm
Alarm
Alarm
Alarm Display:
Display:
Display:
Display:
E1
E1
E1
E1
E2
E2
E2
E2
E3
E3
E3
E3
E4
E4
E4
E4
E5
E5
E5
E5
Over
Over
Over
Over high
high
high
high
room
room
room
room
temperature
temperature
temperature
temperature
Over
Over
Over
Over high
high
high
high
water
water
water
water
temperature
temperature
temperature
temperature
Over
Over
Over
Over low
low
low
low
water
water
water
water
temperature
temperature
temperature
temperature
Room
Room
Room
Room
temperature
temperature
temperature
temperature
sensor
sensor
sensor
sensor failure
failure
failure
failure
Water
Water
Water
Water
temperature
temperature
temperature
temperature
sensor
sensor
sensor
sensor failure
failure
failure
failure
When
When
When
When alarm
alarm
alarm
alarm occurs,
occurs,
occurs,
occurs, the
the
the
the error
error
error
error code
code
code
code and
and
and
and the
the
the
the temperature
temperature
temperature
temperature will
will
will
will be
be
be
be alternately
alternately
alternately
alternately
displayed.
displayed.
displayed.
displayed.
(2)
(2)
(2)
(2) To
To
To
To suspend
suspend
suspend
suspend the
the
the
the alarm:
alarm:
alarm:
alarm:
In
In
In
In alarming
alarming
alarming
alarming state,
state,
state,
state, the
the
the
the alarm
alarm
alarm
alarm sound
sound
sound
sound could
could
could
could be
be
be
be suspended
suspended
suspended
suspended by
by
by
by pressing
pressing
pressing
pressing any
any
any
any button,
button,
button,
button,
but
but
but
but the
the
the
the alarm
alarm
alarm
alarm display
display
display
display remains
remains
remains
remains until
until
until
until the
the
the
the alarm
alarm
alarm
alarm condition
condition
condition
condition is
is
is
is eliminated.
eliminated.
eliminated.
eliminated.
4.
4.
4.
4.
Thermostat
Thermostat
Thermostat
Thermostat parameters
parameters
parameters
parameters list
list
list
list
Order
Order
Order
Order
Code
Code
Code
Code
Item
Item
Item
Item
Range
Range
Range
Range
T-503
T-503
T-503
T-503
Temperature
Temperature
Temperature
Temperature
controller
controller
controller
controller
Factory
Factory
Factory
Factory Setting
Setting
Setting
Setting
T-50
T-50
T-50
T-504
4
4
4
Temperature
Temperature
Temperature
Temperature
controller
controller
controller
controller
Factory
Factory
Factory
Factory Setting
Setting
Setting
Setting
Note
Note
Note
Note
1
1
1
1
F0
F0
F0
F0
Temperature
Temperature
Temperature
Temperature
setting
setting
setting
setting
F9~F8
F9~F8
F9~F8
F9~F8
25
25
25
25
25
25
25
25
Constant
Constant
Constant
Constant
temperature
temperature
temperature
temperature
control
control
control
control
effecting
effecting
effecting
effecting
2
2
2
2
F1
F1
F1
F1
Temperature
Temperature
Temperature
Temperature
Difference
Difference
Difference
Difference values
values
values
values
-15~+5
-15~+5
-15~+5
-15~+5
-2
-2
-2
-2
-2
-2
-2
-2
Intelligent
Intelligent
Intelligent
Intelligent
control
control
control
control
effecting
effecting
effecting
effecting
3
3
3
3
F2
F2
F2
F2
Cooling
Cooling
Cooling
Cooling
hysteresis
hysteresis
hysteresis
hysteresis
0.1~3.0
0.1~3.0
0.1~3.0
0.1~3.0
0.8
0.8
0.8
0.8
0.
0.
0.
0.1
1
1
1
4
4
4
4
F3
F3
F3
F3
Way
Way
Way
Way of
of
of
of control
control
control
control
0~1
0~1
0~1
0~1
1
1
1
1
0
0
0
0
1:
1:
1:
1: intelligent
intelligent
intelligent
intelligent
0:
0:
0:
0: constant
constant
constant
constant
temperature
temperature
temperature
temperature
5
5
5
5
F4
F4
F4
F4
Alarm
Alarm
Alarm
Alarm for
for
for
for over
over
over
over high
high
high
high
water
water
water
water temperature
temperature
temperature
temperature
1~20
1~20
1~20
1~20
10
10
10
10
10
10
10
10
6
6
6
6
F5
F5
F5
F5
Alarm
Alarm
Alarm
Alarm for
for
for
for over
over
over
over low
low
low
low
water
water
water
water temperature
temperature
temperature
temperature
1~20
1~20
1~20
1~20
15
15
15
15
15
15
15
15
7
7
7
7
F6
F6
F6
F6
Alarm
Alarm
Alarm
Alarm for
for
for
for over
over
over
over high
high
high
high
room
room
room
room temperature
temperature
temperature
temperature
40~50
40~50
40~50
40~50
45
45
45
45
45
45
45
45
8
8
8
8
F7
F7
F7
F7
Password
Password
Password
Password
00~99
00~99
00~99
00~99
8
8
8
8
8
8
8
8
9
9
9
9
F8
F8
F8
F8
The
The
The
The allowed
allowed
allowed
allowed highest
highest
highest
highest
water
water
water
water temperature
temperature
temperature
temperature
F0~40
F0~40
F0~40
F0~40
30
30
30
30
30
30
30
30
10
10
10
10
F9
F9
F9
F9
The
The
The
The allowed
allowed
allowed
allowed lowest
lowest
lowest
lowest
water
water
water
water temperature
temperature
temperature
temperature
1~F0
1~F0
1~F0
1~F0
20
20
20
20
20
20
20
20