background image

                                 

Page 4, Rev. 7 

23 Walpole Park South, Walpole, Massachusetts  02081, • Phone: 1-800-343-3381 

www.sanborntechnologies.com

 

• E-mail: [email protected]

 

If the basket is removed through an oil layer or the unit is drained with free-oil on top of 
the unit, then the media will need to be cleaned prior to reuse.  To remove the oil layer, 
close the oil outlet valve then close the discharge valve at the end of the discharge line.  
Allow the level to rise in the media tank several inches above the oil discharge weir.  

Observe this process to avoid overflowing the media tank which would cause liquid 
to spill on the floor.

  Turn the unit off for 10 minutes allowing the oil to rise then open 

the oil charge valve and allow all the fluid (oil and process fluid) to drain to the oil 
storage container.  After the level has drained back to the normal operating level you can 
then remove the media basket. 
 
A drain line at the bottom of the system allows for the removal of residual coolant or 
wash water in the media tank. 
 
Exceeding the rated flow to the Freddy TOS may affect the quantity of tramp oil the unit 
can effectively remove. 
 
If required, prime the electric pump by opening the valve at the bottom of the media tank 
and filling the pump. 
 
Disconnect the unit from the power supply in the event of a problem. 

 

Summary of Contents for Freddy TOS

Page 1: ...chnologies 23 Walpole Park South Walpole MA 02081 2558 Telephone 1 800 343 3381 Fax 1 508 660 9151 info sanborntechnologies com www sanborntechnologies com Section 2 General Operating Instructions 1 Electric Units Check electric cord for wear and grounding Plug the unit into a 110 1 60 outlet 2 Air Operated Units The unit requires a minimum of 15 psi at 0 5 SCFM air flow to operate Ensure the left...

Page 2: ...nute After adjustment press the knob down in the locking position 5 Installation Procedure The unit should be operated on a level solid base with brakes engaged on the casters All outlet pipes should have the shortest possible run length A First Time installation procedure is supplied separately 6 Start up Procedure IMPORTANT Follow the First Time Installation and Start up Procedure Also perform t...

Page 3: ...s as necessary periodic flushing of the sediment which may accumulate in the bottom of the unit and rarely cleaning the filter media if it becomes clogged with sediment The filter media can be cleaned by removing the basket and using a hose or power washer on the media See Precautions below Daily Check all hoses for damage and verify connections are tight Drain the oil from the tank if necessary C...

Page 4: ...ing the media tank which would cause liquid to spill on the floor Turn the unit off for 10 minutes allowing the oil to rise then open the oil charge valve and allow all the fluid oil and process fluid to drain to the oil storage container After the level has drained back to the normal operating level you can then remove the media basket A drain line at the bottom of the system allows for the remov...

Page 5: ...Page 5 Rev 7 23 Walpole Park South Walpole Massachusetts 02081 Phone 1 800 343 3381 www sanborntechnologies com E mail info sanborntechnologies com ...

Reviews: