Set up Vibration Detection Function
The Home Unit has built-in vibration detection function.
Once the Home Unit is moved and detected by vibration sensor, the Home Unit will report periodical vibration
event with loud beep sound. This MT event which generates MT reports will end when the home unit stops
moving.
There are two types of command, the short one is for toggling the function quickly and the long one is for setting
up all the parameter
SMS Setup Format: #
「
USERNAME
」
,
「
Password
」
,
「
Function Mode
」
,
「
ON/OFF
」
,
「
Report Interval
」
,
「
Report
times
」
,
「
Sensitivity
」
*
SMS Command: #username,0000,vs,1*
#username,0000,vs,1,60,2,4*
COTA Setup format
:
<@PCswvs>, <ON/OFF>, <Report Interval>, <Report Times>, <Sensitivity>
COTA Command: @PCswvs,1,60,2,4
SMS/ COTA Command Description
#
Start sign.
USERNAME
Default ID of the device.
If you have changed the user name, please use the updated one.
0000
Default password.
If you have changed the password, please use the updated one.
vs
“vs” defines the MT report setup mode
1
ON/OFF switch. (1: ON, 0: OFF)
60
MT Report interval (60 sec.). The range is 15 to 65000.
2
Total report times (2 times)
4
Sensitivity ranges from 1 (most sensitive) to 10(least sensitive). The default value is
4
*
End sign.
Table38: Tamper Function Setup Format Description
11F., No.2, Sec. 4, Jhongyang Rd., Tucheng Dist., New Taipei City 236, Taiwan (R.O.C.)
Tel: 886-2-22694456
|
Fax: 886-2-22694451
|
33
w
w
©
U
nic
tro
n
Te
ch
no
lo
gie
s
C
or
p.
A
ll
sp
ec
ific
at
io
ns
su
bje
ct
to
ch
an
ge
w
ith
ou
t
no
tic
e.