10. PID GROUP
10.1 PID Range Setting
10.1.1 PID Application Range Setup Screen-1
▶
Consists of 6 PID’s.
▶
Corresponding PID number is displayed with light green color for Fix, Program Run.
▶
Range High, Range Low : The value indicates for all Span.
☞
This is read only, and can not be changed.
▶
REF.HYS : Sets Hysteresis Width when selecting PID Group in ZONE PID.
▶
DEV.PID : Sets Deviation when selecting Deviation PID.
▶
REF.1-4 : Sets Reference Points which divides ZONE PID for all Span.
▶
Tuning Point : Sets Auto Tuning Point applied for Auto Tuning.
①
Move to corresponding PID Group Setup Screen when pressing the number.
☞
Pressing the
button will move to PID Group Setup Screen.
②
Moe the screen Up/Down.
[Figure 10-1] PID Application Range Setup Screen-1