background image

 

SAMWON ENG CO.,LTD                 SU-105 Controller User Manual                                      Page 

1/3

 

Automatic Temperature Controller SU-105 User Manual 

Model 

Temperature range 

Output 

SU-105 IP 

IC 

(-50.0℃~150℃) 

Main/Aux(DC12V) 

Main/Aux(Relay) 

※ Thank you for purchasing a SamWon ENG CO.,LTD 
   product. This manual contains the information on how 
   to use the product. Keep it in a safe place and refer to it 
   whenever necessary. 

 
 
 
 
 
 
 
 
 
 
 
 
 
 

Display Unit 

 

Displays a current temperature or user-set 

 temperature

 

Main/Aux Output 

 

Indicates the main or auxiliary output is 

 ON or OFF

 

Set key 

Up key 

Down key 

 

 Setting button 

 Increment button 

 Decrement button 

 
 

Power controller for heaters and coolers 

  Hysteresis 0.0~9.9 degree C., 0~240 second delay timer, Normal/Reverse selection.

 

 ▶

Contains a digital timer to control defrosting. Range: 1~999 minute.

 

User configuration control

 

˚

You can specify a valid temperature range that a user is allowed to use.

 

˚

You can prevent a user from changing the setting of hysteresis, delay time, 

  and normal/reverse.

 

 
 

Turn on the power and wait until the current  

  temperature appears on the display.

 

Press set key once and notice  

  the display unit blinks. 

Use Up or Dn key to change the setting.  

  If you hold down a key for longer than  
  4 seconds, the number will increase or 
  decrease rapidly. 
Note: The selectable range might be  
  limited by User configuration control. 

Store the setting in memory by pressing 

  set key for longer than 5 seconds. 

 

 ▶

The unit show the current temperature 

   and start working.

 

The main output uses terminal 7 ~ 9. 

Note: For information on Auxiliary 

output (Alarm/Timer), refer to Section 

  

13. How to set Alarm Output. 

 

 

 

 How to connect sensors 

When connecting sensors, use the 

  following figure. If you connect the 
  lines incorrectly or a different type 
  of sensors, the display unit will 
  show ‘

Err

’. 

 ②

 Sensor line extension

 

A Pt100 sensor line can be extended 

  up to 100 M.

 

An IC/Humidity sensor line can be 

  extended up to 500 M. 

You MUST use a shielded line to prevent 

  the noise when extending a line. 

 Sensor input correction (when current temperature is incorrect) 

Press set key for longer than 5 seconds, when the display unit shows a current 

  temperature

 

Release the key when you see 

diF

. Select 

rSt

 by pressing set key. 

Select a correction temperature using Up or Dn key. 

Store the setting in memory by pressing the set key for longer than 5 seconds. 

  For example, 

Current 

temperature 

 

rSt

 corrected 

temperature 

 

Displayed 

current 

temperature 

20.0 ℃ 


-5.0 ℃ 


15.0 ℃ 

20.0 ℃ 

10.0 ℃ 

30.0 ℃ 

 
 
 
 
 
 
 
 
 
 

 

 

Voltage 

 AC220V (50/60Hz) ±10% (AC110V,option) 

Power 

 5VA or less 

Input Sensor 

 K(CA) with a load/line of 100Ω or less 
 PT100Ω with a load/line of 5Ω or less 

Accuracy 

 K(CA):display the value ±0.5% +1digit 
 Pt100:display the value ±0.2% +1digit 

Hysteresis 

 0.1℃ ~ 9.9℃ 

Control output 

 Relay Output:AC250V 5A 
 Relay life time:300,000 or grater 

Control operation 

 ON/OFF Control 

Setting Methode 

 Digital Methode with Up or Down key 

Etc. 

 Sensor input correction,Delay timer,Normal/Reverse selection,Defrosting Timer 

Environment Temperature   0℃ ~ 50℃ 

Environment humidity 

 85% RH or less 

 

 
 

 
 

 

 

1. Description of display

 

set 

up 
dn 

 

2.Capability and applications of the product

 

 

3.How to set main output

 

<Main Output Terminal>

 

   Coil 

Magnet 

메인 
전원 

작동  
기계 

AC 

220V 

Pow 

er 

Mac 
hine 

<Display Current>

 

①Red/White ②Shield/Black

 

 

4. How to connect sensors

 

①White②Black③Black

 

 

5.External dimension 

70 

34 

76 

28 

PANEL CUT OUT 

70 

(unit: mm) 

 

6.Product specification 

<Rear panel terminal>

 

Sensor 

Aux output 

  Main output 

Power 

sh 

RELAY 

3A 

 

RELAY 

3A 

AC 

220V 

R/W 

 

 

 
 

 

① ② ③ ④ ⑤ ⑥    ⑦ ⑧ ⑨ ⑩

 

 

 

    A                B      B

 

                                    RTD 
 +     - 
    TC 

Sensor 

Aux output 

  Main output 

Power 

sh 

RELAY 

3A 

 

RELAY 

3A 

AC 

220V 

R,W 

 

 

 
 

 

① ② ③ ④ ⑤ ⑥    ⑦ ⑧ ⑨ ⑩

 

 

 

up 

dn 

set 

on 

 

Up key 

Set key 

Display Unit 

Down Key 

Main Output 

IC/HUM 

Ca-K 

 
 

  Head Office and Factory : #703-4 Hwamokdong Gimhae Gyoungnam, South Korea

                           

Phone : 82-055-321-3030/1   Fax : 321-3060 

Homepage 

http://31eng.co.kr/

   E-mail : [email protected] 

In Pursuit of Perfect Production for Customer Service Excellence. 

 

 

Reviews: