BURNER INJECTOR VALUES
ACCORDING TO
THE GAS TYPE
LPG
G31/37 mbar
NG
G20/20 mbar
NG
G25/25 mbar
Wok
Burner
Injector Ø mm
0,96
1,30
1,30
Power kW
3,50
3,50
3,50
Consuption
Gr/h,m³/h
252
0,330
0,330
Rapid
Burner
Injector Ø mm
0,85
1,15
1,15
Power kW
2,90
2,90
2,90
Consuption
Gr/h,m³/h
208,80
0,274
0,274
Semi
Rapid
Burner
Injector Ø mm
0,65
0,97
0,97
Power kW
1,70
1,70
1,70
Consuption
Gr/h,m³/h
122,40
0,170
0,170
Auxiliary
Burner
Injector Ø mm
0,50
0,72
0,72
Power kW
0,95
0,95
0,95
Consuption
Gr/h,m³/h
68,4
0,090
0,090
Oven
Burner
Injector Ø mm
0,65
0,97
0,97
Power kW
1,80
1,80
1,80
Consuption
Gr/h,m³/h
129,60
0,170
0,170
Grill
Burner
Injector Ø mm
0,60
0,92
0,92
Power kW
1,50
1,50
1,50
Consuption
Gr/h,m³/h
108
0,142
0,142
IF THE APPLIANCE DOES NOT OPERATE
1.
Please check the plug of power supply cord has a well connection
with wall socket or not.
2.
Please check the electric network.
3.
Please check the fuse.
4.
Please check power supply cord for any damage problems.
5.
If you can not solve the problem, get in contact with manufacturer
supplier service agent or similar qualified persons.