TABLE OF CONTENTS
Contents
Page No.
S.No
1
Welcome message
1
2
Complying Norms
1
3
Contents in the Packing Box
1
4
Introduction about Product and Briefing
1
5
Schematic Drawings & Indication of Parts
2
6
Key Product Specifications and Features
3
7
Pre-Installation Requirements
4
8
Installation Procedure
8
9
Important Safety Instructions
12
10
Storage and Handling
12
1
1. WELCOME MESSAGE
Dear Customer:
Welcome to the Samudra family! Thank you for choosing products from Samudra.
We congratulate you and value your decision made on choosing our products. You
are entitled to enjoy the best in class product and service.
2. COMPLYING NORMS
IS 3043
: Code of Practice for Earthing-Specification
IS 9283
: Motors for Submersible Pumpsets-Specification
IS 13730 : Specifications for Particular Types of Winding Wires
IS 14220 : Open well Submersible Pumpsets-Specification
3. CONTENTS OF THE PACKING BOX
Based on model you have purchased, your Open Well Submersible Monoblocs is
packed along with instruction manual in a Corrugated Box / Wooden Crate.
4. INTRODUCTION ABOUT PRODUCT AND BRIEFING
The discharge of a pump depends on the static suction lift. During summer, the
static suction lift increases due to drop in water levels, and this results in reduced
discharge. This will require frequent lowering of the pump to reduce the static
suction lift. During monsoons, water levels can significantly rise. Under such
conditions, there is a possibility that the pump can get submerged resulting in the
motor getting damaged. To overcome the issue of varying static suction lifts, Open
Well Submersible Monobloc (OWS) has been introduced. Such a pump operates
submerged.
Samudra OWS are manufactured using high quality raw materials and components
using state-of-the-art manufacturing facilities and will give trouble-free
performance if they are properly installed and maintained. The OWS are compact
pumping systems with the pump and motor mounted on a common shaft. As a
coupling is not required, alignment of the pump and motor is assured. Installation
therefore becomes quick. OWS do not require frequent maintenance as packing
rope and grease lubricated deep groove ball bearings are replaced by oil seals and
water lubricated journal bearings respectively. OWS find application for pumping
from wells, sumps, borewells, located at the bottom of the well, rivers, canals, lakes,
etc..
Prior to installation, read this manual carefully and follow instructions for
installation and maintenance of our OWS to ensure reliable operation. The OWS
should be installed by technically qualified personnel in compliance with national
and local electrical codes and as per our instructions in order to avoid electrical
shocks, unsatisfactory performance, and equipment failure.
Summary of Contents for SSM-N Series
Page 1: ......